-
1
-
-
0003958379
-
-
HPA, London
-
Birch R., Marshall M., and Ardran G.M. Catalogue of Spectral Data for Diagnostic X-rays SRS, 30 (1979), HPA, London
-
(1979)
Catalogue of Spectral Data for Diagnostic X-rays SRS, 30
-
-
Birch, R.1
Marshall, M.2
Ardran, G.M.3
-
2
-
-
0025210885
-
Needle beam studies of HPGe detectors for photon efficiency calibration from 6 to 25 keV
-
Burns P.A., Martin L.J., and Moroney R.J. Needle beam studies of HPGe detectors for photon efficiency calibration from 6 to 25 keV. Nucl. Instrum. Methods A 286 (1990) 480-489
-
(1990)
Nucl. Instrum. Methods A
, vol.286
, pp. 480-489
-
-
Burns, P.A.1
Martin, L.J.2
Moroney, R.J.3
-
3
-
-
0031885451
-
Monte Carlo based method for conversion of in-situ gamma ray spectra obtained with a portable Ge detector to an incident photon flux energy distribution
-
Clouvas A., Xanthos S., Antonopoulos-Domis M., et al. Monte Carlo based method for conversion of in-situ gamma ray spectra obtained with a portable Ge detector to an incident photon flux energy distribution. Health Phys. 74 2 (1998) 216-230
-
(1998)
Health Phys.
, vol.74
, Issue.2
, pp. 216-230
-
-
Clouvas, A.1
Xanthos, S.2
Antonopoulos-Domis, M.3
-
4
-
-
33646097574
-
-
Conti, C.C., 1999. Medida de kerma no ar e Determinação de Coeficientes de Conversão para Dose devido à Radiação Gama Ambiental. Tese de D. Sc., UFRJ, Rio de Janeiro, RJ, Brasil.
-
-
-
-
6
-
-
0025941634
-
Determination of X-ray spectra and of the scattered component up to 300 kV
-
Laitano R.F., Pani R., and Pellegrini R. Determination of X-ray spectra and of the scattered component up to 300 kV. Med. Phys. 18 5 (1990) 934-938
-
(1990)
Med. Phys.
, vol.18
, Issue.5
, pp. 934-938
-
-
Laitano, R.F.1
Pani, R.2
Pellegrini, R.3
-
7
-
-
0002011999
-
Monte Carlo calculation of peak efficiencies of Ge(Li) and pure Ge detectors to volumial sources and comparison with environmental radioactivity measurement
-
Nakamura T. Monte Carlo calculation of peak efficiencies of Ge(Li) and pure Ge detectors to volumial sources and comparison with environmental radioactivity measurement. Nucl. Instrum. Methods 205 (1983) 211-218
-
(1983)
Nucl. Instrum. Methods
, vol.205
, pp. 211-218
-
-
Nakamura, T.1
-
8
-
-
0023620943
-
Diagnostic X-ray spectra measurements using a silicon surface barrier detector
-
Pani R., Laitano R.F., and Pellegrini R. Diagnostic X-ray spectra measurements using a silicon surface barrier detector. Phys. Med. Biol. 32 9 (1987) 1135-1149
-
(1987)
Phys. Med. Biol.
, vol.32
, Issue.9
, pp. 1135-1149
-
-
Pani, R.1
Laitano, R.F.2
Pellegrini, R.3
-
9
-
-
0001432286
-
A Monte Carlo based method of including gamma self-absorption for the analysis of environmental samples
-
Sánches F., Nanarro E., Moreno A., and Roldán C. A Monte Carlo based method of including gamma self-absorption for the analysis of environmental samples. Nucl. Instrum. Methods B 61 (1991) 535-540
-
(1991)
Nucl. Instrum. Methods B
, vol.61
, pp. 535-540
-
-
Sánches, F.1
Nanarro, E.2
Moreno, A.3
Roldán, C.4
-
10
-
-
0018751365
-
Stripping of X-ray bremsstrahlung spectra up to 300 kVp on desk type computer
-
Seelentag W.W., and Panzer W. Stripping of X-ray bremsstrahlung spectra up to 300 kVp on desk type computer. Phys. Med. Biol. 24 (1979) 767-780
-
(1979)
Phys. Med. Biol.
, vol.24
, pp. 767-780
-
-
Seelentag, W.W.1
Panzer, W.2
-
11
-
-
0001491113
-
-
Sima, O., 1990. Monte Carlo simulation versus semiempirical calculation of autoabsorption factors for semiconductor detector calibration in complex geometries. Progress in Nuclear Energy, vol. 24. UK, pp. 327-336.
-
-
-
-
12
-
-
33646116418
-
-
X-5 Monte Carlo Team, 2003. MCNP-A General Monte Carlo N-Particle Transport Code, Version 5, Volume I: Overview and Theory, LA-UR-03-1987. Los Alamos National Laboratory.
-
-
-
|