메뉴 건너뛰기




Volumn 17, Issue 4, 2005, Pages 329-339

Vena Cava Filters: Why, When, What, How?

Author keywords

inferior vena cava filter; pulmonary emboli; thromboembolic complication

Indexed keywords

BLOOD VESSEL TRANSPLANTATION; EQUIPMENT DESIGN; HUMAN; LUNG EMBOLISM; PROSTHESIS FAILURE; REVIEW; RISK FACTOR; VEIN THROMBOSIS; VENA CAVA FILTER;

EID: 33646078141     PISSN: 15310035     EISSN: None     Source Type: Journal    
DOI: 10.1177/153100350501700407     Document Type: Article
Times cited : (25)

References (59)
  • 1
    • 0032808867 scopus 로고    scopus 로고
    • Hereditary and acquired thrombophilia. Part I. Preface
    • Bick RL: Hereditary and acquired thrombophilia. Part I. Preface. Semin Thromb Hemost 25:251-253, 1999.
    • (1999) Semin Thromb Hemost , vol.25 , pp. 251-253
    • Bick, R.L.1
  • 2
    • 0032874866 scopus 로고    scopus 로고
    • Prophylactic inferior vena cava filters in trauma patients at high risk: follow-up examination and risk/benefit assessment
    • Langan III E.M., Miller R.S., Casey III W.J., et al: Prophylactic inferior vena cava filters in trauma patients at high risk: follow-up examination and risk/benefit assessment. J Vasc Surg 30:484-490, 1999.
    • (1999) J Vasc Surg , vol.30 , pp. 484-490
    • Langan, E.M.1    Miller, R.S.2    Casey, W.J.3
  • 3
    • 0033811742 scopus 로고    scopus 로고
    • Prevention of venous thromboembolism after injury: anevidencebased report-part II: analysis of risk factors and evaluation of the role of vena caval filters
    • Velmahos G.C., Kern J, Chan L.S., et al: Prevention of venous thromboembolism after injury: anevidencebased report-part II: analysis of risk factors and evaluation of the role of vena caval filters. J Trauma 49:140-144, 2000.
    • (2000) J Trauma , vol.49 , pp. 140-144
    • Velmahos, G.C.1    Kern, J.2    Chan, L.S.3
  • 4
    • 6844254566 scopus 로고    scopus 로고
    • A clinical trial of vena caval filters in the prevention of pulmonary embolism in patients with proximal deepvein thrombosis
    • Decousus H, Leizorovicz A, Parent F, et al: A clinical trial of vena caval filters in the prevention of pulmonary embolism in patients with proximal deepvein thrombosis. N Eng J Med 338:409-415, 1998.
    • (1998) N Eng J Med , vol.338 , pp. 409-415
    • Decousus, H.1    Leizorovicz, A.2    Parent, F.3
  • 5
    • 0023749127 scopus 로고
    • Twelve-year clinical experience with the Greenfield vena caval filter
    • Greenfield L.J., Michna BA: Twelve-year clinical experience with the Greenfield vena caval filter. Surgery 104:706-712, 1988.
    • (1988) Surgery , vol.104 , pp. 706-712
    • Greenfield, L.J.1    Michna, B.A.2
  • 6
    • 0034660529 scopus 로고    scopus 로고
    • Vena caval filters: a comprehensive review
    • Streiff MB: Vena caval filters: a comprehensive review. Blood 95:3669-3677, 2000.
    • (2000) Blood , vol.95 , pp. 3669-3677
    • Streiff, M.B.1
  • 7
    • 0021845639 scopus 로고
    • Free-floating iliofemoral thrombus: a risk of pulmonary embolism
    • Norris C.S., Greenfield L.J., Herrmann JB: Free-floating iliofemoral thrombus: a risk of pulmonary embolism. Arch Surg 120:806-808, 1985.
    • (1985) Arch Surg , vol.120 , pp. 806-808
    • Norris, C.S.1    Greenfield, L.J.2    Herrmann, J.B.3
  • 8
    • 7044280336 scopus 로고    scopus 로고
    • Caval interruption Procedures
    • In Rutherford R. B., editor: Philadelphia W.B. Saunders Company
    • Greenfield LJ: Caval interruption Procedures. In Rutherford R.B., editor: Vascular Surgery. Philadelphia: W.B. Saunders Company; 2000.
    • (2000) Vascular Surgery
    • Greenfield, L.J.1
  • 9
    • 0037351255 scopus 로고    scopus 로고
    • Acute complications associated with Greenfield filter insertion in high-risk trauma patients
    • Duperier T, Mosenthal A, Swan K.G., et al: Acute complications associated with Greenfield filter insertion in high-risk trauma patients. J Trauma 54:545-549, 2003.
    • (2003) J Trauma , vol.54 , pp. 545-549
    • Duperier, T.1    Mosenthal, A.2    Swan, K.G.3
  • 10
    • 0027381476 scopus 로고
    • Prophylactic vena cava filter insertion in severely injured trauma patients: indications and preliminary results
    • Rogers F.B., Shackford S.R., Wilson J, et al: Prophylactic vena cava filter insertion in severely injured trauma patients: indications and preliminary results. J Trauma 35:637-642, 1993.
    • (1993) J Trauma , vol.35 , pp. 637-642
    • Rogers, F.B.1    Shackford, S.R.2    Wilson, J.3
  • 11
    • 0033664958 scopus 로고    scopus 로고
    • Long-term follow-up of trauma patients with a vena caval filter
    • Wojcik R, Cipolle M.D., Fearen I, et al: Long-term follow-up of trauma patients with a vena caval filter. J Trauma 49:839-843, 2000.
    • (2000) J Trauma , vol.49 , pp. 839-843
    • Wojcik, R.1    Cipolle, M.D.2    Fearen, I.3
  • 12
    • 0033748804 scopus 로고    scopus 로고
    • Lessons learned from a 6-year clinical experience with superior vena cava Greenfield filters
    • Ascher E, Hingorani A, Tsemekhin B, et al: Lessons learned from a 6-year clinical experience with superior vena cava Greenfield filters. J Vasc Surg 32:881-887, 2000.
    • (2000) J Vasc Surg , vol.32 , pp. 881-887
    • Ascher, E.1    Hingorani, A.2    Tsemekhin, B.3
  • 13
    • 0035102371 scopus 로고    scopus 로고
    • Endovascular caval interruption in pregnant patients with deep vein thrombosis of the lower extremity
    • Aburahma A.F., Mullins DA: Endovascular caval interruption in pregnant patients with deep vein thrombosis of the lower extremity. J Vasc Surg 33:375-378, 2001.
    • (2001) J Vasc Surg , vol.33 , pp. 375-378
    • Aburahma, A.F.1    Mullins, D.A.2
  • 14
    • 0014623161 scopus 로고
    • Caval interruption for prevention of pulmonary embolism. Long-term results of a new method
    • Mobin-Uddin K, McLean R, Bolooki H, et al: Caval interruption for prevention of pulmonary embolism. Long-term results of a new method. Arch Surg 99: 711-715, 1969.
    • (1969) Arch Surg , vol.99 , pp. 711-715
    • Mobin-Uddin, K.1    McLean, R.2    Bolooki, H.3
  • 15
    • 0015608691 scopus 로고
    • A new intracaval filter permitting continued flow and resolution of emboli
    • Greenfield L.J., McCurdy J.R., Brown P.P., et al: A new intracaval filter permitting continued flow and resolution of emboli. Surgery 73:599-606, 1973.
    • (1973) Surgery , vol.73 , pp. 599-606
    • Greenfield, L.J.1    McCurdy, J.R.2    Brown, P.P.3
  • 16
    • 0037287546 scopus 로고    scopus 로고
    • Preliminary results of the new 6F TrapEase inferior vena cava filter
    • Schutzer R, Ascher E, Hingorani A, et al: Preliminary results of the new 6F TrapEase inferior vena cava filter. Ann Vasc Surg 17:103-106, 2003.
    • (2003) Ann Vasc Surg , vol.17 , pp. 103-106
    • Schutzer, R.1    Ascher, E.2    Hingorani, A.3
  • 17
    • 0024370179 scopus 로고
    • Preliminary clinical experience with the titanium Greenfield vena caval filter
    • Greenfield L.J., Cho K.J., Pais S.O., et al: Preliminary clinical experience with the titanium Greenfield vena caval filter. Arch Surg 124:657-659, 1989.
    • (1989) Arch Surg , vol.124 , pp. 657-659
    • Greenfield, L.J.1    Cho, K.J.2    Pais, S.O.3
  • 18
    • 0030827530 scopus 로고    scopus 로고
    • The Bird's Nest inferior vena caval filter: review of a single-center experience
    • Wojtowycz M.M., Stoehr T, Crummy A.B., et al: The Bird's Nest inferior vena caval filter: review of a single-center experience. J Vasc Interv Radiol 8:171-179, 1997.
    • (1997) J Vasc Interv Radiol , vol.8 , pp. 171-179
    • Wojtowycz, M.M.1    Stoehr, T.2    Crummy, A.B.3
  • 19
    • 0024403825 scopus 로고
    • Simon nitinol inferior vena cava filter: initial clinical experience. Work in progress
    • Simon M, Athanasoulis C.A., Kim D, et al: Simon nitinol inferior vena cava filter: initial clinical experience. Work in progress. Radiology 172:99-103, 1989.
    • (1989) Radiology , vol.172 , pp. 99-103
    • Simon, M.1    Athanasoulis, C.A.2    Kim, D.3
  • 20
    • 0031755116 scopus 로고    scopus 로고
    • Clinical experience with the antecubital Simon nitinol IVC filter
    • Engmann E, Asch MR: Clinical experience with the antecubital Simon nitinol IVC filter. J Vasc Interv Radiol 9:774-778, 1998.
    • (1998) J Vasc Interv Radiol , vol.9 , pp. 774-778
    • Engmann, E.1    Asch, M.R.2
  • 21
    • 0036131184 scopus 로고    scopus 로고
    • Placement of a vena cava filter with an antecubital approach
    • Stavropoulos S.W., Clark T, Jacobs D, et al: Placement of a vena cava filter with an antecubital approach. Acad Radiol 9:478-481, 2002.
    • (2002) Acad Radiol , vol.9 , pp. 478-481
    • Stavropoulos, S.W.1    Clark, T.2    Jacobs, D.3
  • 22
    • 0033984854 scopus 로고    scopus 로고
    • Current practice of temporary vena cava filter insertion: a multicenter registry
    • Lorch H, Welger D, Wagner V, et al: Current practice of temporary vena cava filter insertion: a multicenter registry. J Vasc Interv Radiol 11:83-88, 2000.
    • (2000) J Vasc Interv Radiol , vol.11 , pp. 83-88
    • Lorch, H.1    Welger, D.2    Wagner, V.3
  • 23
    • 0029006547 scopus 로고
    • Worsening of proximal thrombosis after insertion of a temporary caval filter (3 cases)
    • Carcone B, Pernes J.M., Carcopino J.M., et al: Worsening of proximal thrombosis after insertion of a temporary caval filter (3 cases). Rev Med Interne 16:351-353, 1995.
    • (1995) Rev Med Interne , vol.16 , pp. 351-353
    • Carcone, B.1    Pernes, J.M.2    Carcopino, J.M.3
  • 24
    • 0031594781 scopus 로고    scopus 로고
    • A rare complication with an Antheor vena cava filter
    • Stosslein F, Altmann E: A rare complication with an Antheor vena cava filter. Cardiovasc Interv Radiol 21:165-167, 1998.
    • (1998) Cardiovasc Interv Radiol , vol.21 , pp. 165-167
    • Stosslein, F.1    Altmann, E.2
  • 25
    • 0034852141 scopus 로고    scopus 로고
    • Gunther Tulip retrievable vena cava filter: results from the Registry of the Canadian Interventional Radiology Association
    • Millward S.F., Oliva V.L., Bell S.D., et al: Gunther Tulip retrievable vena cava filter: results from the Registry of the Canadian Interventional Radiology Association. J Vasc Interv Radiol 12:1053-1058, 2001.
    • (2001) J Vasc Interv Radiol , vol.12 , pp. 1053-1058
    • Millward, S.F.1    Oliva, V.L.2    Bell, S.D.3
  • 26
  • 27
    • 0027283608 scopus 로고
    • New retrievable percutaneous vena cava filter: experimental in vitro and in vivo evaluation
    • Neuerburg J, Gunther R.W., Rassmussen E, et al: New retrievable percutaneous vena cava filter: experimental in vitro and in vivo evaluation. Cardiovasc Intervent Radiol 16:224-229, 1993.
    • (1993) Cardiovasc Intervent Radiol , vol.16 , pp. 224-229
    • Neuerburg, J.1    Gunther, R.W.2    Rassmussen, E.3
  • 28
    • 0142028256 scopus 로고    scopus 로고
    • Retrievable vena cava filter placement during treatment for deep venous thrombosis
    • Yamagami T, Kato T, Iida S, et al: Retrievable vena cava filter placement during treatment for deep venous thrombosis. Br J Radiol 76:712-718, 2003.
    • (2003) Br J Radiol , vol.76 , pp. 712-718
    • Yamagami, T.1    Kato, T.2    Iida, S.3
  • 29
    • 0036892706 scopus 로고    scopus 로고
    • Initial experience in humans with a new retrievable inferior vena cava filter
    • Asch MR: Initial experience in humans with a new retrievable inferior vena cava filter. Radiology 225:835-844, 2002.
    • (2002) Radiology , vol.225 , pp. 835-844
    • Asch, M.R.1
  • 30
    • 0033812822 scopus 로고    scopus 로고
    • Filter placement by ultrasound technique at the bedside
    • Matsumura J.S., Morasch MD: Filter placement by ultrasound technique at the bedside. Semin Vasc Surg 13:199-203, 2000.
    • (2000) Semin Vasc Surg , vol.13 , pp. 199-203
    • Matsumura, J.S.1    Morasch, M.D.2
  • 31
    • 0032886224 scopus 로고    scopus 로고
    • Intravascular ultrasound-guided vena cava filter placement
    • Oppat W.F., Chiou A.C., Matsumura JS: Intravascular ultrasound-guided vena cava filter placement. J Endovasc Surg 6:285-287, 1999.
    • (1999) J Endovasc Surg , vol.6 , pp. 285-287
    • Oppat, W.F.1    Chiou, A.C.2    Matsumura, J.S.3
  • 32
    • 0036484255 scopus 로고    scopus 로고
    • Duplex scan-directed placement of inferior vena cava filters: a five-year institutional experience
    • Conners III M.S., Becker S, Guzman R.J., et al: Duplex scan-directed placement of inferior vena cava filters: a five-year institutional experience. J Vasc Surg 35:286-291, 2002.
    • (2002) J Vasc Surg , vol.35 , pp. 286-291
    • Conners, M.S.1    Becker, S.2    Guzman, R.J.3
  • 33
    • 0035405932 scopus 로고    scopus 로고
    • Bedside vena cava filter placement guided with intravascular ultrasound
    • Ebaugh J.L., Chiou A.C., Morasch M.D., et al: Bedside vena cava filter placement guided with intravascular ultrasound. J Vasc Surg 34:21-26, 2001.
    • (2001) J Vasc Surg , vol.34 , pp. 21-26
    • Ebaugh, J.L.1    Chiou, A.C.2    Morasch, M.D.3
  • 34
    • 0023577590 scopus 로고
    • Accidental placement of the Greenfield filter in the heart: report of two cases
    • Hirsch S.B., Harrington E.B., Miller C.M., et al: Accidental placement of the Greenfield filter in the heart: report of two cases. J Vasc Surg 6:609-610, 1987.
    • (1987) J Vasc Surg , vol.6 , pp. 609-610
    • Hirsch, S.B.1    Harrington, E.B.2    Miller, C.M.3
  • 35
    • 0031612487 scopus 로고    scopus 로고
    • Long-term results of the Simon nitinol inferior vena cava filter
    • Poletti P.A., Becker C.D., Prina L, et al: Long-term results of the Simon nitinol inferior vena cava filter. Eur Radiol 8:289-294, 1998.
    • (1998) Eur Radiol , vol.8 , pp. 289-294
    • Poletti, P.A.1    Becker, C.D.2    Prina, L.3
  • 36
    • 0032695232 scopus 로고    scopus 로고
    • Deep venous thrombosis after percutaneous insertion of vena caval filters
    • Blebea J, Wilson R, Waybill P, et al: Deep venous thrombosis after percutaneous insertion of vena caval filters. J Vasc Surg 30:821-829, 1999.
    • (1999) J Vasc Surg , vol.30 , pp. 821-829
    • Blebea, J.1    Wilson, R.2    Waybill, P.3
  • 37
    • 0023801470 scopus 로고
    • Femoral arteriovenous fistula after placement of a Kimray-Greenfield filter
    • Grassi C.J., Bettmann M.A., Rogoff P, et al: Femoral arteriovenous fistula after placement of a Kimray-Greenfield filter. Am J Roentgenol 151:681-682, 1988.
    • (1988) Am J Roentgenol , vol.151 , pp. 681-682
    • Grassi, C.J.1    Bettmann, M.A.2    Rogoff, P.3
  • 38
    • 0035102963 scopus 로고    scopus 로고
    • Recurrent thromboembolism in patients with vena cava filters
    • Greenfield L.J., Proctor MC: Recurrent thromboembolism in patients with vena cava filters. J Vasc Surg 33:510-514, 2001.
    • (2001) J Vasc Surg , vol.33 , pp. 510-514
    • Greenfield, L.J.1    Proctor, M.C.2
  • 39
    • 0027074519 scopus 로고
    • The Simon nitinol inferior vena cava filter: preliminaiy experience in the UK
    • Hawkins S.P., al-Kutoubi A: The Simon nitinol inferior vena cava filter: preliminaiy experience in the UK. Clin Radiol 46:378-380, 1992.
    • (1992) Clin Radiol , vol.46 , pp. 378-380
    • Hawkins, S.P.1    al-Kutoubi, A.2
  • 40
    • 0026623378 scopus 로고
    • The Simon nitinol filter: evaluation by MR and ultrasound
    • Kim D, Edelman R.R., Margolin C.J., et al: The Simon nitinol filter: evaluation by MR and ultrasound. Angiology 43:541-548, 1992.
    • (1992) Angiology , vol.43 , pp. 541-548
    • Kim, D.1    Edelman, R.R.2    Margolin, C.J.3
  • 41
    • 0026902886 scopus 로고
    • Vena caval occlusion after Simon nitinol filter placement: identification with MR imaging in patients with malignancy
    • Grassi C.J., Matsumoto A.H., Teitelbaum GP: Vena caval occlusion after Simon nitinol filter placement: identification with MR imaging in patients with malignancy. J Vasc Interv Radiol 3:535-539, 1992.
    • (1992) J Vasc Interv Radiol , vol.3 , pp. 535-539
    • Grassi, C.J.1    Matsumoto, A.H.2    Teitelbaum, G.P.3
  • 42
    • 0028840044 scopus 로고
    • Comparative efficacy and complications of vena caval filters
    • Mohan C.R., Hoballah J.J., Sharp W.J., et al: Comparative efficacy and complications of vena caval filters. J Vasc Surg 21:235-246, 1995.
    • (1995) J Vasc Surg , vol.21 , pp. 235-246
    • Mohan, C.R.1    Hoballah, J.J.2    Sharp, W.J.3
  • 43
    • 0028961196 scopus 로고
    • Twenty-year clinical experience with the Greenfield filter
    • Greenfield L.J., Proctor MC: Twenty-year clinical experience with the Greenfield filter. Cardiovasc Surg 3:199-205, 1995.
    • (1995) Cardiovasc Surg , vol.3 , pp. 199-205
    • Greenfield, L.J.1    Proctor, M.C.2
  • 44
    • 0037335493 scopus 로고    scopus 로고
    • Filter-related, thrombotic occlusion of the inferior vena cava treated with a Gianturco stent
    • Joshi A, Carr J, Chrisman H, et al: Filter-related, thrombotic occlusion of the inferior vena cava treated with a Gianturco stent. J Vasc Interv Radiol 14:381-385, 2003.
    • (2003) J Vasc Interv Radiol , vol.14 , pp. 381-385
    • Joshi, A.1    Carr, J.2    Chrisman, H.3
  • 45
    • 8944251135 scopus 로고    scopus 로고
    • Complications of inferior vena cava filters. Abdom Imaging
    • Ray CE Jr., Kaufman JA: Complications of inferior vena cava filters. Abdom Imaging. 1996;21:368-374.
    • (1996) , vol.21 , pp. 368-374
    • Ray, C.E.1    Kaufman, J.A.2
  • 46
    • 0033946238 scopus 로고    scopus 로고
    • Inferior vena caval filters: review of a 26-year singlecenter clinical experience
    • Athanasoulis C.A., Kaufman J.A., Halpern E.F., et al: Inferior vena caval filters: review of a 26-year singlecenter clinical experience. Radiology 216:54-66, 2000.
    • (2000) Radiology , vol.216 , pp. 54-66
    • Athanasoulis, C.A.1    Kaufman, J.A.2    Halpern, E.F.3
  • 47
    • 0036231858 scopus 로고    scopus 로고
    • Delayed retroperitoneal arterial hemorrhage after inferior vena cava (IVC) filter insertion: case report and literature review of caval perforations by IVC filters
    • Woodward E.B., Farber A, Wagner W.H., et al: Delayed retroperitoneal arterial hemorrhage after inferior vena cava (IVC) filter insertion: case report and literature review of caval perforations by IVC filters. Ann Vasc Surg 16:193-196, 2002.
    • (2002) Ann Vasc Surg , vol.16 , pp. 193-196
    • Woodward, E.B.1    Farber, A.2    Wagner, W.H.3
  • 48
    • 0025975719 scopus 로고
    • Late arterial hemorrhage secondary to a Greenfield filter requiring operative intervention
    • Howerton R.M., Watkins M, Feldman L: Late arterial hemorrhage secondary to a Greenfield filter requiring operative intervention. Surgery 109:265-268, 1991.
    • (1991) Surgery , vol.109 , pp. 265-268
    • Howerton, R.M.1    Watkins, M.2    Feldman, L.3
  • 49
    • 0030889812 scopus 로고    scopus 로고
    • Greenfield filter caval perforation causing an aortic mural thrombus and femoral artery occlusion
    • Chintalapudi U.B., Gutierrez O.H., Azodo MV: Greenfield filter caval perforation causing an aortic mural thrombus and femoral artery occlusion. Cathet Cardiovasc Diagn 41:53-55, 1997.
    • (1997) Cathet Cardiovasc Diagn , vol.41 , pp. 53-55
    • Chintalapudi, U.B.1    Gutierrez, O.H.2    Azodo, M.V.3
  • 50
    • 0027214248 scopus 로고
    • Penetration of the wall of an abdominal aortic aneurysm by a Greenfield filter prong: a late complication
    • Kurgan A, Nunnelee J.D., Auer AI: Penetration of the wall of an abdominal aortic aneurysm by a Greenfield filter prong: a late complication. J Vasc Surg 18:303-306, 1993.
    • (1993) J Vasc Surg , vol.18 , pp. 303-306
    • Kurgan, A.1    Nunnelee, J.D.2    Auer, A.I.3
  • 51
    • 0029113444 scopus 로고
    • Late complication of a Greenfield filter associating caudal migration and perforation of the abdominal aorta by a ruptured strut
    • Dabbagh A, Chakfe N, Kretz J.G., et al: Late complication of a Greenfield filter associating caudal migration and perforation of the abdominal aorta by a ruptured strut. J Vasc Surg. 22:182-187, 1995.
    • (1995) J Vasc Surg , vol.22 , pp. 182-187
    • Dabbagh, A.1    Chakfe, N.2    Kretz, J.G.3
  • 52
    • 0029853726 scopus 로고    scopus 로고
    • Ureteral injury secondary to an inferior vena caval filter
    • Goldman H.B., Hanna K, Dmochowski RR: Ureteral injury secondary to an inferior vena caval filter. J Urol 156:1763-1764, 1996.
    • (1996) J Urol , vol.156 , pp. 1763-1764
    • Goldman, H.B.1    Hanna, K.2    Dmochowski, R.R.3
  • 53
    • 0029924196 scopus 로고    scopus 로고
    • Caval umrbrella causing obstructive uropathy
    • Flanagan D, Creasy T, Chataway F, et al: Caval umrbrella causing obstructive uropathy. Postgrad Med J 72:235-237, 1996.
    • (1996) Postgrad Med J , vol.72 , pp. 235-237
    • Flanagan, D.1    Creasy, T.2    Chataway, F.3
  • 54
    • 0030815271 scopus 로고    scopus 로고
    • An unusual cause of upper gastrointestinal haemorrhage-perforation of a vena cava filter into the duodenum
    • Sarkar M.R., Lemminger FM: An unusual cause of upper gastrointestinal haemorrhage-perforation of a vena cava filter into the duodenum. Vasa 26:305-307. 1997.
    • (1997) Vasa , vol.26 , pp. 305-307
    • Sarkar, M.R.1    Lemminger, F.M.2
  • 55
    • 0030891866 scopus 로고    scopus 로고
    • Duodenal perforation by a Greenfield filter: endoscopic diagnosis
    • Bianchini A.U., Mehta S.N., Mulder D.S., et al: Duodenal perforation by a Greenfield filter: endoscopic diagnosis. Am J Gastroenterol 92:686-687, 1997.
    • (1997) Am J Gastroenterol , vol.92 , pp. 686-687
    • Bianchini, A.U.1    Mehta, S.N.2    Mulder, D.S.3
  • 56
    • 0029395668 scopus 로고
    • Bird's Nest inferior vena caval filter migration into the duodenum: a rare cause of upper gastrointestinal bleeding
    • al Zahrani HA: Bird's Nest inferior vena caval filter migration into the duodenum: a rare cause of upper gastrointestinal bleeding. J Endovasc Surg 2:372-375, 1995.
    • (1995) J Endovasc Surg , vol.2 , pp. 372-375
    • al Zahrani, H.A.1
  • 57
    • 0026316459 scopus 로고
    • Intracardiac and intrapulmonary Greenfield filters: a long-term follow-up
    • Gelbfish G.A., Ascer E: Intracardiac and intrapulmonary Greenfield filters: a long-term follow-up. J Vasc Surg 14:614-617, 1991.
    • (1991) J Vasc Surg , vol.14 , pp. 614-617
    • Gelbfish, G.A.1    Ascer, E.2
  • 58
    • 0029800522 scopus 로고    scopus 로고
    • Tricuspid insufficiency after intracardiac migration of a Greenfield filter: case report and review of the literature
    • James K.V., Sobolewski A.P., Lohr J.M., et al: Tricuspid insufficiency after intracardiac migration of a Greenfield filter: case report and review of the literature. J Vasc Surg 24:494-498, 1996.
    • (1996) J Vasc Surg , vol.24 , pp. 494-498
    • James, K.V.1    Sobolewski, A.P.2    Lohr, J.M.3
  • 59
    • 0028394272 scopus 로고
    • LGM (Vena Tech) vena caval filter: experience at a single institution
    • Millward S.F., Peterson R.A., Moher D, et al: LGM (Vena Tech) vena caval filter: experience at a single institution. J Vasc Interv Radiol 5:351-356, 1994.
    • (1994) J Vasc Interv Radiol , vol.5 , pp. 351-356
    • Millward, S.F.1    Peterson, R.A.2    Moher, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.