메뉴 건너뛰기




Volumn 8, Issue 3, 2006, Pages 343-348

Determination of the diagnostic value of the resazurin reduction assay for evaluating boar semen by receiver operating characteristic analysis

Author keywords

Cut off point selection; Porcine; Receiver operating characteristic analysis; Resazurin reduction assay; Semen

Indexed keywords

RESAZURIN;

EID: 33646023968     PISSN: 1008682X     EISSN: 17457262     Source Type: Journal    
DOI: 10.1111/j.1745-7262.2006.00130.x     Document Type: Article
Times cited : (7)

References (20)
  • 1
    • 0031320821 scopus 로고    scopus 로고
    • Assessment of boar sperm function in relation to freezing and storage
    • Holt WV, Medrano A. Assessment of boar sperm function in relation to freezing and storage. J Reprod Fertil Suppl 1997; 52: 213-22.
    • (1997) J Reprod Fertil Suppl , vol.52 , pp. 213-222
    • Holt, W.V.1    Medrano, A.2
  • 3
    • 0036958350 scopus 로고    scopus 로고
    • Evaluation and assessment of semen for IVF/ICSI
    • Liu DY, Baker HW. Evaluation and assessment of semen for IVF/ICSI. Asian J Androl 2002; 4: 281-5.
    • (2002) Asian J Androl , vol.4 , pp. 281-285
    • Liu, D.Y.1    Baker, H.W.2
  • 4
    • 84907127267 scopus 로고
    • Modified resazurin reduction test for determining the fertility potential of bovine spermatozoa
    • Dart MG, Mesta J, Creshaw C, Ericsson SA. Modified resazurin reduction test for determining the fertility potential of bovine spermatozoa. Arch Androl 1994; 33: 71-5.
    • (1994) Arch Androl , vol.33 , pp. 71-75
    • Dart, M.G.1    Mesta, J.2    Creshaw, C.3    Ericsson, S.A.4
  • 6
    • 0027964182 scopus 로고
    • Comparison of the resazurin test, adenosine triphosphate in semen, and various sperm parameters
    • Mahmoud AM, Comhaire FH, Vermeulen L, Andreou E. Comparison of the resazurin test, adenosine triphosphate in semen, and various sperm parameters. Hum Reprod 1994; 9: 1688-93.
    • (1994) Hum Reprod , vol.9 , pp. 1688-1693
    • Mahmoud, A.M.1    Comhaire, F.H.2    Vermeulen, L.3    Andreou, E.4
  • 7
    • 0030989318 scopus 로고    scopus 로고
    • Enlarged spectrum of seminological diagnoses using the resazurin colour reaction, a spectrophotometric application
    • Rahman NA, Kula K. Enlarged spectrum of seminological diagnoses using the resazurin colour reaction, a spectrophotometric application. Int J Androl 1997; 20: 17-22.
    • (1997) Int J Androl , vol.20 , pp. 17-22
    • Rahman, N.A.1    Kula, K.2
  • 8
    • 7844229858 scopus 로고    scopus 로고
    • The correlates and alleged biochemical background of the resazurin reduction test in semen
    • Zalata AA, Lammertijn N, Christoper A, Comhaire FH. The correlates and alleged biochemical background of the resazurin reduction test in semen. Int J Androl 1998; 21: 289-94.
    • (1998) Int J Androl , vol.21 , pp. 289-294
    • Zalata, A.A.1    Lammertijn, N.2    Christoper, A.3    Comhaire, F.H.4
  • 9
    • 6544281469 scopus 로고    scopus 로고
    • Spectrophotometric analysis of resazurin reduction test and semen quality in men
    • Reddy KV, Bordekar AD. Spectrophotometric analysis of resazurin reduction test and semen quality in men. Indian J Exp Biol 1999; 37: 782-6.
    • (1999) Indian J Exp Biol , vol.37 , pp. 782-786
    • Reddy, K.V.1    Bordekar, A.D.2
  • 10
  • 11
    • 17444434439 scopus 로고    scopus 로고
    • Spectrophotometric application of resazurin reduction assay to evaluate boar semen quality
    • Zrimsek P, Kunc J, Kosec M, Mrkun J. Spectrophotometric application of resazurin reduction assay to evaluate boar semen quality. Int J Androl 2004; 27: 57-62.
    • (2004) Int J Androl , vol.27 , pp. 57-62
    • Zrimsek, P.1    Kunc, J.2    Kosec, M.3    Mrkun, J.4
  • 12
    • 0034732869 scopus 로고    scopus 로고
    • Principles and practical application of the receiver-operating characteristic analysis for diagnostic tests
    • Greiner M, Pfeiffer D, Smith RD. Principles and practical application of the receiver-operating characteristic analysis for diagnostic tests. Prev Vet Med 2000; 54: 23-41.
    • (2000) Prev Vet Med , vol.54 , pp. 23-41
    • Greiner, M.1    Pfeiffer, D.2    Smith, R.D.3
  • 13
    • 0029028843 scopus 로고
    • A modified ROC analysis for the selection of cut-off values and the definition of intermediate results of serodiagnostic tests
    • Greiner M, Sohr D, Gobel P. A modified ROC analysis for the selection of cut-off values and the definition of intermediate results of serodiagnostic tests. J Immunol Methods 1995; 185: 123-32.
    • (1995) J Immunol Methods , vol.185 , pp. 123-132
    • Greiner, M.1    Sohr, D.2    Gobel, P.3
  • 14
    • 0002199564 scopus 로고
    • Semen evaluation
    • 6th ed Philadelphia: Lea&Febiger
    • Hafez, ES Semen evaluation. In: Reproduction in Farm animals. 6th ed Philadelphia: Lea&Febiger 1993. p 405-23.
    • (1993) Reproduction in Farm Animals , pp. 405-423
    • Hafez, E.S.1
  • 15
    • 2942674310 scopus 로고    scopus 로고
    • Sexual function of premature ejaculation patients assayed with Chinese Index of Premature Ejaculation
    • Yuan YM, Xin ZC, Jiang H, Guo YJ, Liu WJ, Tian L, et al. Sexual function of premature ejaculation patients assayed with Chinese Index of Premature Ejaculation. Asian J Androl 2004; 6: 121-6.
    • (2004) Asian J Androl , vol.6 , pp. 121-126
    • Yuan, Y.M.1    Xin, Z.C.2    Jiang, H.3    Guo, Y.J.4    Liu, W.J.5    Tian, L.6
  • 16
    • 0032403282 scopus 로고    scopus 로고
    • Slopes of a receiver operating characteristic curve and likelihood ratios for a diagnostic test
    • Choi BC. Slopes of a receiver operating characteristic curve and likelihood ratios for a diagnostic test. Am J Epidemiol 1998; 148: 1127-32.
    • (1998) Am J Epidemiol , vol.148 , pp. 1127-1132
    • Choi, B.C.1
  • 17
    • 3042760005 scopus 로고    scopus 로고
    • Receiver operating characteritic (ROC) to determine cut-off points of biomarkers in lung cancer patients
    • Weiss HL, Niwas S, Grizzle WE, Piyathilake C. Receiver operating characteritic (ROC) to determine cut-off points of biomarkers in lung cancer patients. Dis Markers 2003-2004; 19: 273-8.
    • (2003) Dis Markers , vol.19 , pp. 273-278
    • Weiss, H.L.1    Niwas, S.2    Grizzle, W.E.3    Piyathilake, C.4
  • 19
    • 0002377459 scopus 로고    scopus 로고
    • Data for diagnosis and monitoring
    • Burnett, D Association of Clinical Biochemists. London, UK: ACB Venture Publications
    • Jones GJ, Payne RB. Data for diagnosis and monitoring. In: Clinical Investigation and Statistics in Laboratory Medicine, Burnett, D Association of Clinical Biochemists. London, UK: ACB Venture Publications 1997. p 66-124.
    • (1997) Clinical Investigation and Statistics in Laboratory Medicine , pp. 66-124
    • Jones, G.J.1    Payne, R.B.2
  • 20
    • 0027457620 scopus 로고
    • Receiver-operating characteristic (ROC) plots: A fundamental evaluation tool in clinical medicine
    • Erratum in: Clin Chem 1993; 39: 1589
    • Zweig MH, Campbell G. Receiver-operating characteristic (ROC) plots: A fundamental evaluation tool in clinical medicine. Clin Chem 1993; 39: 561-77. Erratum in: Clin Chem 1993; 39: 1589.
    • (1993) Clin Chem , vol.39 , pp. 561-577
    • Zweig, M.H.1    Campbell, G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.