Volumn 17, Issue 10, 2005, Pages 546-547

Sizing balloon-induced tear of the atrial septum

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; BALLOON CATHETER; CASE REPORT; DIAGNOSTIC PROCEDURE; FEMALE; HEART ATRIUM SEPTUM DEFECT; HEART CATHETERIZATION; HEART INJURY; HEART SURGERY; HEMATOMA; HUMAN; SHUNTING; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; TRANSTHORACIC ECHOCARDIOGRAPHY; TREATMENT OUTCOME;

EID: 33646013644     PISSN: 10423931     EISSN: 15572501     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (17)

References (5)
  • 1
    • 0037303172 scopus 로고    scopus 로고
    • Experience with transcatheter closure of secundum atrial septal defects using the Amplatzer septal occluder: A single center study in 236 consecutive patients
    • Fischer G, Stieh J, Uebing A, et al. Experience with transcatheter closure of secundum atrial septal defects using the Amplatzer septal occluder: A single center study in 236 consecutive patients. Heart 2003;89:199-204.
    • (2003) Heart , vol.89 , pp. 199-204
    • Fischer, G.1    Stieh, J.2    Uebing, A.3
  • 2
    • 4644247244 scopus 로고    scopus 로고
    • Short- and intermediate-term results of transcatheter closure of atrial septal defect with the Amplatzer Septal Occluder
    • Wang JK, Tsai SK, Wu MH, et al. Short- and intermediate-term results of transcatheter closure of atrial septal defect with the Amplatzer Septal Occluder. Am Heart J 2004;148:511-517.
    • (2004) Am Heart J , vol.148 , pp. 511-517
    • Wang, J.K.1    Tsai, S.K.2    Wu, M.H.3
  • 3
    • 18344388292 scopus 로고    scopus 로고
    • Early and late complications associated with transcatheter occlusion of secundum atrial septal defect
    • Chessa M, Carminati M, Butera G, et al. Early and late complications associated with transcatheter occlusion of secundum atrial septal defect. J Am Coll Cardiol 2002;39:1061-1065.
    • (2002) J Am Coll Cardiol , vol.39 , pp. 1061-1065
    • Chessa, M.1    Carminati, M.2    Butera, G.3
  • 4
    • 0035033779 scopus 로고    scopus 로고
    • Pitfalls of atrial septal defect sizing using Meditech sizing balloon
    • Lee C-H, Kwok O-H, Chow W-H. Pitfalls of atrial septal defect sizing using Meditech sizing balloon. Catheter Cardiovasc Interv 2001;53:94-95.
    • (2001) Catheter Cardiovasc Interv , vol.53 , pp. 94-95
    • Lee, C.-H.1    Kwok, O.-H.2    Chow, W.-H.3
  • 5
    • 0032947365 scopus 로고    scopus 로고
    • A new technique for sizing of atrial septal defects
    • Gu X, Han Y-M, Berry J,e t al. A new technique for sizing of atrial septal defects. Catheter Cardiovasc Interv 1999;46:51-57.
    • (1999) Catheter Cardiovasc Interv , vol.46 , pp. 51-57
    • Gu, X.1    Han, Y.-M.2    Berry, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.