메뉴 건너뛰기




Volumn 34, Issue 4, 2006, Pages 564-574

Influence of multiple stenoses on echo-doppler functional diagnosis of peripheral arterial disease: A numerical and experimental study

Author keywords

In vitro experiments; Lower limb vascular diseases; Multiple arterial stenoses; Numerical simulations; Ultrasound diagnosis

Indexed keywords

COMPUTER SIMULATION; DIAGNOSIS; DOPPLER EFFECT; MATHEMATICAL MODELS; NUMERICAL ANALYSIS; ULTRASONICS;

EID: 33646007963     PISSN: 00906964     EISSN: 15739686     Source Type: Journal    
DOI: 10.1007/s10439-005-9071-7     Document Type: Article
Times cited : (22)

References (38)
  • 1
    • 0021750666 scopus 로고
    • Pulsatile flow studies with laser Doppler anemometry
    • Ahmed, S. A., and D. P. Giddens. Pulsatile flow studies with laser Doppler anemometry. J. Biomech. 17:695-705, 1984.
    • (1984) J. Biomech. , vol.17 , pp. 695-705
    • Ahmed, S.A.1    Giddens, D.P.2
  • 2
    • 0028294443 scopus 로고
    • Limitations of ultrasonic duplex scanning for diagnosing lower limb arterial stenoses in the presence of adjacent segment disease
    • Allard, L., G. Cloutier, L. G. Durand, et al. Limitations of ultrasonic duplex scanning for diagnosing lower limb arterial stenoses in the presence of adjacent segment disease. J. Vase. Surg. 19(4):650-657, 1994.
    • (1994) J. Vase. Surg. , vol.19 , Issue.4 , pp. 650-657
    • Allard, L.1    Cloutier, G.2    Durand, L.G.3
  • 3
    • 0029069548 scopus 로고
    • Doppler velocity ratio measurements evaluated in a phantom model of multiple arterial disease
    • Allard, L., G. Cloutier, and L. G. Durand. Doppler velocity ratio measurements evaluated in a phantom model of multiple arterial disease. Ultrasound Med. Biol. 21(4):471-480, 1995.
    • (1995) Ultrasound Med. Biol. , vol.21 , Issue.4 , pp. 471-480
    • Allard, L.1    Cloutier, G.2    Durand, L.G.3
  • 4
    • 0032962812 scopus 로고    scopus 로고
    • Review of the assessment of single level and multilevel arterial occlusive disease in lower limbs by duplex ultrasound
    • Allard, L., G. Cloutier, Z. Guo, et al. Review of the assessment of single level and multilevel arterial occlusive disease in lower limbs by duplex ultrasound. Ultrasound Med. Biol. 25(4):495-502, 1999.
    • (1999) Ultrasound Med. Biol. , vol.25 , Issue.4 , pp. 495-502
    • Allard, L.1    Cloutier, G.2    Guo, Z.3
  • 5
    • 0031770378 scopus 로고    scopus 로고
    • Duplex scanning and effect of multisegmental arterial disease on its accuracy in lower limb arteries
    • Aly, S., M. P. Jenkins, F. H. Zaidi, et al. Duplex scanning and effect of multisegmental arterial disease on its accuracy in lower limb arteries. Eur. J. Vasc. Endovasc. Surg. 16:345-349, 1998.
    • (1998) Eur. J. Vasc. Endovasc. Surg. , vol.16 , pp. 345-349
    • Aly, S.1    Jenkins, M.P.2    Zaidi, F.H.3
  • 6
    • 0029319835 scopus 로고
    • Mathematical modelling of triple arterial stenoses
    • Ang, K. C., and J. Mazumdar. Mathematical modelling of triple arterial stenoses. Australas. Phys. Eng. Sci. Med. 18(2):89-94, 1995.
    • (1995) Australas. Phys. Eng. Sci. Med. , vol.18 , Issue.2 , pp. 89-94
    • Ang, K.C.1    Mazumdar, J.2
  • 7
    • 0036710832 scopus 로고    scopus 로고
    • Duplex selection facilitates single point-of-service endovascular and surgical management of aortoiliac occlusive disease
    • Back, M. R., A. N. Bowser, D. C. Schmacht, et al. Duplex selection facilitates single point-of-service endovascular and surgical management of aortoiliac occlusive disease. Ann. Vase. Surg. 16(5):566-574, 2002.
    • (2002) Ann. Vase. Surg. , vol.16 , Issue.5 , pp. 566-574
    • Back, M.R.1    Bowser, A.N.2    Schmacht, D.C.3
  • 8
    • 0029022828 scopus 로고
    • Effect of multilevel sequential stenosis on lower extremity arterial duplex scanning
    • Bergamini, T. M., C. M. Tatum Jr, C. Marshall, et al. Effect of multilevel sequential stenosis on lower extremity arterial duplex scanning. Am. J. Surg. 169(6):564-566, 1995.
    • (1995) Am. J. Surg. , vol.169 , Issue.6 , pp. 564-566
    • Bergamini, T.M.1    Tatum Jr., C.M.2    Marshall, C.3
  • 9
    • 3042563316 scopus 로고    scopus 로고
    • A multimodality vascular imaging phantom with fiducial markers visible in DSA, CTA, MRA and ultrasound
    • Cloutier, G., G. Soulez, S. D. Qanadli, et al. A multimodality vascular imaging phantom with fiducial markers visible in DSA, CTA, MRA and ultrasound. Med. Phys. 31(6): 1424-1433, 2004.
    • (2004) Med. Phys. , vol.31 , Issue.6 , pp. 1424-1433
    • Cloutier, G.1    Soulez, G.2    Qanadli, S.D.3
  • 10
    • 0029920806 scopus 로고    scopus 로고
    • Duplex velocity characteristics of aortoiliac stenoses
    • De Smet, A. A., E. J. Eimers, and P. J. Kitslaar. Duplex velocity characteristics of aortoiliac stenoses. J. Vase. Surg. 23(4):628-636, 1996.
    • (1996) J. Vase. Surg. , vol.23 , Issue.4 , pp. 628-636
    • De Smet, A.A.1    Eimers, E.J.2    Kitslaar, P.J.3
  • 11
    • 0032429524 scopus 로고    scopus 로고
    • Low Reynolds number turbulence modeling of blood flow in arterial stenoses
    • Ghalichi, F., X. Deng, A. De Champlain, et al. Low Reynolds number turbulence modeling of blood flow in arterial stenoses. Biorheology 35:281-294, 1998.
    • (1998) Biorheology , vol.35 , pp. 281-294
    • Ghalichi, F.1    Deng, X.2    De Champlain, A.3
  • 12
    • 0032965034 scopus 로고    scopus 로고
    • A comparison of single- and dual-beam methods for maximum velocity estimation
    • Hoskins, P. R. A comparison of single- and dual-beam methods for maximum velocity estimation. Ultrasound Med. Biol. 4:583-592, 1999.
    • (1999) Ultrasound Med. Biol. , vol.4 , pp. 583-592
    • Hoskins, P.R.1
  • 13
    • 0027477122 scopus 로고
    • Impact of color-flow duplex surveillance program on infrainguinal vein graft patency: A five-year experience
    • Idu, M. M., J. D. Blankenstein, P. De Gier, et al. Impact of color-flow duplex surveillance program on infrainguinal vein graft patency: A five-year experience. J. Vase. Surg. 17:42-52, 1993.
    • (1993) J. Vase. Surg. , vol.17 , pp. 42-52
    • Idu, M.M.1    Blankenstein, J.D.2    De Gier, P.3
  • 14
    • 0021883286 scopus 로고
    • Noninvasive mapping of lower limb arterial lesions
    • Jager, K. A., D. J. Phillips, R. L. Martin, et al. Noninvasive mapping of lower limb arterial lesions. Ultrasound Med. Biol. 11(3):515-521, 1985.
    • (1985) Ultrasound Med. Biol. , vol.11 , Issue.3 , pp. 515-521
    • Jager, K.A.1    Phillips, D.J.2    Martin, R.L.3
  • 15
    • 0027369651 scopus 로고
    • Fundamental sources of error and spectral broadening in Doppler ultrasound signals
    • Jones, S.A. Fundamental sources of error and spectral broadening in Doppler ultrasound signals. Crit. Rev. Biomed. Eng. 21(5):399-483, 1993.
    • (1993) Crit. Rev. Biomed. Eng. , vol.21 , Issue.5 , pp. 399-483
    • Jones, S.A.1
  • 16
    • 0022450901 scopus 로고
    • Some observations on the evolution of shear layer instabilities in laminar flow through axisymmetric sudden expansion
    • Latornell, D. J., A. Pollard. Some observations on the evolution of shear layer instabilities in laminar flow through axisymmetric sudden expansion. Phys. Fluids 29(9):677-681, 1986.
    • (1986) Phys. Fluids , vol.29 , Issue.9 , pp. 677-681
    • Latornell, D.J.1    Pollard, A.2
  • 17
    • 0028005685 scopus 로고
    • Steady laminar fluid flow through variable constrictions in vascular tube
    • Lee, T. S. Steady laminar fluid flow through variable constrictions in vascular tube. J. Fluids Eng. 116:66-71, 1994.
    • (1994) J. Fluids Eng. , vol.116 , pp. 66-71
    • Lee, T.S.1
  • 18
    • 0027536998 scopus 로고
    • Accuracy and reproducibility of duplex ultrasonography in grading femoropopliteal stenoses
    • Leng, G. C., M. R. Whyman, P. T. Donnan, et al. Accuracy and reproducibility of duplex ultrasonography in grading femoropopliteal stenoses. J. Vase. Surg. 17(3):510-517, 1993.
    • (1993) J. Vase. Surg. , vol.17 , Issue.3 , pp. 510-517
    • Leng, G.C.1    Whyman, M.R.2    Donnan, P.T.3
  • 19
    • 33646007580 scopus 로고    scopus 로고
    • Échographie-Doppler dans l'artériopathie oblitérante des membres inférieurs
    • Juin
    • Matignon, Y. Échographie-Doppler dans l'artériopathie oblitérante des membres inférieurs. ©Agence Nationale d'Accréditation et d'Évaluation en Santé. Juin 2002. Available at: http://www.anaes.fr/anaes/Publications.nsf/nPDFFile/
    • (2002) ©Agence Nationale d'Accréditation et d'Évaluation en Santé.
    • Matignon, Y.1
  • 20
    • 33645997622 scopus 로고    scopus 로고
    • RA.LILF-5EHJD7/$File/echodoppler.rap.pdf. Accessed on October, 2003
    • RA.LILF-5EHJD7/$File/echodoppler.rap.pdf. Accessed on October, 2003.
  • 21
    • 0026559354 scopus 로고
    • Accuracy of lower extremity arterial duplex mapping
    • Moneta, G. L., R. A. Yeager, R. Antonovic, et al. Accuracy of lower extremity arterial duplex mapping. J. Vasc. Surg. 15(2):275-284, 1992.
    • (1992) J. Vasc. Surg. , vol.15 , Issue.2 , pp. 275-284
    • Moneta, G.L.1    Yeager, R.A.2    Antonovic, R.3
  • 22
    • 0024682444 scopus 로고
    • Pulsatile flow through constricted tube: An experimental investigation using photochromic methods
    • Ojha, M., R. S. C. Cobbold, K. W. Johnston, et al. Pulsatile flow through constricted tube: An experimental investigation using photochromic methods. J. Fluid Mech. 203:173-197, 1989.
    • (1989) J. Fluid Mech. , vol.203 , pp. 173-197
    • Ojha, M.1    Cobbold, R.S.C.2    Johnston, K.W.3
  • 23
    • 0032832428 scopus 로고    scopus 로고
    • Effects of multiple stenoses and post-stenotic dilatation on non-Newtonian blood flow in small arteries
    • Pincombe, B., J. Mazumdar, I. Hamilton-Craig. Effects of multiple stenoses and post-stenotic dilatation on non-Newtonian blood flow in small arteries. Med. Biol. Eng. Comput. 37(5):595-599, 1999.
    • (1999) Med. Biol. Eng. Comput. , vol.37 , Issue.5 , pp. 595-599
    • Pincombe, B.1    Mazumdar, J.2    Hamilton-Craig, I.3
  • 24
    • 0032848708 scopus 로고    scopus 로고
    • The role of duplex scanning in the diagnosis of lower limb arterial disease
    • Ramaswami, G., A. Al-Kutoubi, A. N. Nicolaides, et al. The role of duplex scanning in the diagnosis of lower limb arterial disease. Ann. Vasc. Surg. 13(5):494-500, 1999.
    • (1999) Ann. Vasc. Surg. , vol.13 , Issue.5 , pp. 494-500
    • Ramaswami, G.1    Al-Kutoubi, A.2    Nicolaides, A.N.3
  • 25
    • 0026631495 scopus 로고
    • Duplex scanning of the peripheral arteries: Correlation of the peak velocity ratio with angiographic diameter reduction
    • Ranke, C., A. Creutzig, and K. Alexander. Duplex scanning of the peripheral arteries: correlation of the peak velocity ratio with angiographic diameter reduction. Ultrasound Med. Biol. 18(5):433-440, 1992.
    • (1992) Ultrasound Med. Biol. , vol.18 , Issue.5 , pp. 433-440
    • Ranke, C.1    Creutzig, A.2    Alexander, K.3
  • 26
    • 0028784526 scopus 로고
    • A wallless vessel phantom for Doppler ultrasound studies
    • Rickey, D. W., P. A. Picot, D. A. Christopher, et al. A wallless vessel phantom for Doppler ultrasound studies. Ultrasound Med. Biol. 21(9): 1163-1176, 1995.
    • (1995) Ultrasound Med. Biol. , vol.21 , Issue.9 , pp. 1163-1176
    • Rickey, D.W.1    Picot, P.A.2    Christopher, D.A.3
  • 27
    • 0027056913 scopus 로고
    • Peripheral arterial Doppler ultrasonography: Diagnostic criteria
    • Sacks, D., M. L. Robinson, D. L. Marinelli, et al. Peripheral arterial Doppler ultrasonography: diagnostic criteria. J. Ultrasound Med. 11(3):95-103, 1992.
    • (1992) J. Ultrasound Med. , vol.11 , Issue.3 , pp. 95-103
    • Sacks, D.1    Robinson, M.L.2    Marinelli, D.L.3
  • 28
    • 0017087359 scopus 로고
    • Effect of geometry on pressure losses across models of arterial stenoses
    • Seeley, B. D., and D. F. Young. Effect of geometry on pressure losses across models of arterial stenoses. J. Biomech. 9:439-448, 1976.
    • (1976) J. Biomech. , vol.9 , pp. 439-448
    • Seeley, B.D.1    Young, D.F.2
  • 29
    • 0029789907 scopus 로고    scopus 로고
    • The effect of adjacent segment disease on the accuracy of colour duplex scanning for the diagnosis of lower limb arterial disease
    • Sensier, Y., T. Hartshorne, A. Thrush, et al. The effect of adjacent segment disease on the accuracy of colour duplex scanning for the diagnosis of lower limb arterial disease. Eur. J. Vasc. Endovasc. Surg. 12(2):238-242, 1996.
    • (1996) Eur. J. Vasc. Endovasc. Surg. , vol.12 , Issue.2 , pp. 238-242
    • Sensier, Y.1    Hartshorne, T.2    Thrush, A.3
  • 30
    • 0344043455 scopus 로고    scopus 로고
    • Experimental analysis of unsteady flows through a stenosis
    • Siouffi, M., V. Deplano, and R. Pélissier. Experimental analysis of unsteady flows through a stenosis. J. Biomech. 31(1): 11-19, 1997.
    • (1997) J. Biomech. , vol.31 , Issue.1 , pp. 11-19
    • Siouffi, M.1    Deplano, V.2    Pélissier, R.3
  • 31
    • 0035001406 scopus 로고    scopus 로고
    • Sources of errors in maximum velocity estimation using linear-array doppler systems with steady flow
    • Steinman, A. H., J. Tavakkoli, J. G. Myers, et al. Sources of errors in maximum velocity estimation using linear-array doppler systems with steady flow. Ultrasound Med. Biol. 5:655-664, 2001.
    • (2001) Ultrasound Med. Biol. , vol.5 , pp. 655-664
    • Steinman, A.H.1    Tavakkoli, J.2    Myers, J.G.3
  • 32
    • 0035099493 scopus 로고    scopus 로고
    • Interobserver variability in aortoiliac and femoropopliteal duplex scanning
    • Ubbink, D. T., M. Fidler, and D. A. Legemate. Interobserver variability in aortoiliac and femoropopliteal duplex scanning. J. Vasc. Surg. 33:540-545, 2001.
    • (2001) J. Vasc. Surg. , vol.33 , pp. 540-545
    • Ubbink, D.T.1    Fidler, M.2    Legemate, D.A.3
  • 33
    • 0024711343 scopus 로고
    • Steady flow through a double converging-diverging tube model for mild stenoses
    • van Dreumel, S. C., and G. D. C. Kuiken. Steady flow through a double converging-diverging tube model for mild stenoses. J. Biomech. Eng. 111:212-221, 1989.
    • (1989) J. Biomech. Eng. , vol.111 , pp. 212-221
    • Van Dreumel, S.C.1    Kuiken, G.D.C.2
  • 34
    • 0042476695 scopus 로고    scopus 로고
    • Numerical modeling of pulsatile turbulent flow in stenotic vessels
    • Varghese, S. S., and S. H. Frankel. Numerical modeling of pulsatile turbulent flow in stenotic vessels. J. Biomech. Eng. 125:445-460, 2003.
    • (2003) J. Biomech. Eng. , vol.125 , pp. 445-460
    • Varghese, S.S.1    Frankel, S.H.2
  • 36
    • 0015669825 scopus 로고
    • Flow characteristics in models of arterial stenoses - II. Unsteady flow
    • Young, D., and F. Tsai. Flow characteristics in models of arterial stenoses - II. Unsteady flow. J. Biomech. 6:547-559 1973.
    • (1973) J. Biomech. , vol.6 , pp. 547-559
    • Young, D.1    Tsai, F.2
  • 37
    • 0017402284 scopus 로고
    • Hemodynamics of arterial stenoses at elevated flow rates
    • Young, D., N. Cholvin, R. Kirkeeide, and A. Roth. Hemodynamics of arterial stenoses at elevated flow rates. Circ. Res. 41(1):99-107, 1977.
    • (1977) Circ. Res. , vol.41 , Issue.1 , pp. 99-107
    • Young, D.1    Cholvin, N.2    Kirkeeide, R.3    Roth, A.4
  • 38
    • 0018340074 scopus 로고
    • Initiation of turbulence in models of arterial stenoses
    • Youngchareon, W., and D. Young. Initiation of turbulence in models of arterial stenoses. J. Biomech. 12:185-196, 1979.
    • (1979) J. Biomech. , vol.12 , pp. 185-196
    • Youngchareon, W.1    Young, D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.