메뉴 건너뛰기




Volumn 3, Issue 5, 2006, Pages 612-614

Pacemaker troubleshooting: When MVP is not the most valuable parameter

Author keywords

[No Author keywords available]

Indexed keywords

AGED; ALGORITHM; ARTICLE; ARTIFICIAL HEART PACEMAKER; ATRIOVENTRICULAR BLOCK; ATRIOVENTRICULAR CONDUCTION; AUTOMATIC CARDIOVERSION; AUTOMATION; CASE REPORT; CLINICAL FEATURE; DEFIBRILLATOR; DIFFERENTIAL DIAGNOSIS; ELECTROCARDIOGRAPHY; HEART ATRIUM FIBRILLATION; HEART ATRIUM PACING; HEART LEFT BUNDLE BRANCH BLOCK; HEART RATE; HEART VENTRICLE PACING; HUMAN; MALE; P WAVE; PACEMAKER FAILURE; PR INTERVAL; PRIORITY JOURNAL; QRS COMPLEX; R WAVE; RR INTERVAL; SINUS NODE DYSFUNCTION; SINUS RHYTHM;

EID: 33646003532     PISSN: 15475271     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.hrthm.2005.12.028     Document Type: Article
Times cited : (26)

References (14)
  • 1
    • 0042230998 scopus 로고    scopus 로고
    • Adverse effects of ventricular desynchronization induced by long-term right ventricular pacing
    • Barold S.S. Adverse effects of ventricular desynchronization induced by long-term right ventricular pacing. J Am Coll Cardiol 42 (2003) 624-628
    • (2003) J Am Coll Cardiol , vol.42 , pp. 624-628
    • Barold, S.S.1
  • 3
    • 0038311033 scopus 로고    scopus 로고
    • Adverse effect of ventricular pacing on heart failure and atrial fibrillation among patients with normal baseline QRS duration in a clinical trial of pacemaker therapy for sinus node dysfunction
    • Sweeney M.O., Hellkamp A.S., Ellenbogen K.A., Greenspon A.J., Freedman R.A., Lee K.L., and Lamas G.A. Adverse effect of ventricular pacing on heart failure and atrial fibrillation among patients with normal baseline QRS duration in a clinical trial of pacemaker therapy for sinus node dysfunction. Circulation 107 (2003) 2932-2937
    • (2003) Circulation , vol.107 , pp. 2932-2937
    • Sweeney, M.O.1    Hellkamp, A.S.2    Ellenbogen, K.A.3    Greenspon, A.J.4    Freedman, R.A.5    Lee, K.L.6    Lamas, G.A.7
  • 4
    • 0037176263 scopus 로고    scopus 로고
    • Dual-chamber pacing or ventricular backup pacing in patients with an implantable defibrillator. the Dual Chamber and VVI Implantable Defibrillator (DAVID) Trial
    • Wilkoff B.L., Cook J.R., Epstein A.E., Greene H.L., Hallstrom A.P., Hsia H., Kutalek S.P., and Sharma A. Dual-chamber pacing or ventricular backup pacing in patients with an implantable defibrillator. the Dual Chamber and VVI Implantable Defibrillator (DAVID) Trial. JAMA 288 (2002) 3115-3123
    • (2002) JAMA , vol.288 , pp. 3115-3123
    • Wilkoff, B.L.1    Cook, J.R.2    Epstein, A.E.3    Greene, H.L.4    Hallstrom, A.P.5    Hsia, H.6    Kutalek, S.P.7    Sharma, A.8
  • 6
    • 0042354585 scopus 로고    scopus 로고
    • A randomized comparison of atrial and dual-chamber pacing in 177 consecutive patients with sick sinus syndrome. echocardiographic and clinical outcome
    • Nielsen J.C., Kristensen L., Andersen H.R., Mortensen P.T., Pedersen O.L., and Pedersen A.K. A randomized comparison of atrial and dual-chamber pacing in 177 consecutive patients with sick sinus syndrome. echocardiographic and clinical outcome. J Am Coll Cardiol 42 (2003) 614-623
    • (2003) J Am Coll Cardiol , vol.42 , pp. 614-623
    • Nielsen, J.C.1    Kristensen, L.2    Andersen, H.R.3    Mortensen, P.T.4    Pedersen, O.L.5    Pedersen, A.K.6
  • 7
    • 0033108060 scopus 로고    scopus 로고
    • Programming a fixed long atrioventricular delay is not effective in preventing ventricular pacing in patients with sick sinus syndrome
    • Nielsen J.C., Pedersen A.K., Mortensen P.T., and Andersen H.R. Programming a fixed long atrioventricular delay is not effective in preventing ventricular pacing in patients with sick sinus syndrome. Europace 1 (1999) 113-120
    • (1999) Europace , vol.1 , pp. 113-120
    • Nielsen, J.C.1    Pedersen, A.K.2    Mortensen, P.T.3    Andersen, H.R.4
  • 8
    • 0013048365 scopus 로고    scopus 로고
    • Atrioventricular interval search. a dual-chamber pacemaker feature to promote intrinsic A-V conduction
    • Silverman R., Casvant D., Loucks S., Lundstrom R., and Lynn T. Atrioventricular interval search. a dual-chamber pacemaker feature to promote intrinsic A-V conduction. Pacing Clin Electrophysiol 22 (1998) 873
    • (1998) Pacing Clin Electrophysiol , vol.22 , pp. 873
    • Silverman, R.1    Casvant, D.2    Loucks, S.3    Lundstrom, R.4    Lynn, T.5
  • 11
    • 2942545738 scopus 로고    scopus 로고
    • Pacemaker mediated tachycardia as a complication of the autointrinsic conduction search function
    • Dennis M.J., and Sparks P.B. Pacemaker mediated tachycardia as a complication of the autointrinsic conduction search function. Pacing Clin Electrophysiol 27 (2004) 824-826
    • (2004) Pacing Clin Electrophysiol , vol.27 , pp. 824-826
    • Dennis, M.J.1    Sparks, P.B.2
  • 12
  • 13
    • 3042776090 scopus 로고    scopus 로고
    • Randomized pilot study of a new atrial-based minimal ventricular pacing mode in dual-chamber implantable cardioverter-defibrillators
    • Sweeney M.O., Shea J.B., Fox V., Adler S., Nelson L., Mullen T.J., Belk P., Casavant D., and Sheldon T. Randomized pilot study of a new atrial-based minimal ventricular pacing mode in dual-chamber implantable cardioverter-defibrillators. Heart Rhythm 1 (2004) 160-167
    • (2004) Heart Rhythm , vol.1 , pp. 160-167
    • Sweeney, M.O.1    Shea, J.B.2    Fox, V.3    Adler, S.4    Nelson, L.5    Mullen, T.J.6    Belk, P.7    Casavant, D.8    Sheldon, T.9
  • 14
    • 26444599967 scopus 로고    scopus 로고
    • Multicenter, prospective, randomized safety and efficacy study of a new atrial-based managed ventricular pacing mode (MVP) in dual chamber ICDs
    • Sweeney M.O., Ellenbogen K.A., Casavant D., Betzold R., Sheldon T., Tang F., Mueller M., and Lingle J. Multicenter, prospective, randomized safety and efficacy study of a new atrial-based managed ventricular pacing mode (MVP) in dual chamber ICDs. J Cardiovasc Electrophysiol 16 (2005) 811-817
    • (2005) J Cardiovasc Electrophysiol , vol.16 , pp. 811-817
    • Sweeney, M.O.1    Ellenbogen, K.A.2    Casavant, D.3    Betzold, R.4    Sheldon, T.5    Tang, F.6    Mueller, M.7    Lingle, J.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.