메뉴 건너뛰기




Volumn 115, Issue 4, 2006, Pages 277-284

Imaging the human vocal folds in vivo with optical coherence tomography: A preliminary experience

Author keywords

Glottis; Laryngeal imaging; Optical coherence tomography; Vocal fold

Indexed keywords

ADULT; ARTICLE; CONNECTIVE TISSUE; ENDOSCOPE; GLOTTIS; HUMAN; IMAGING SYSTEM; LARYNGOSCOPE; LARYNX; MEASUREMENT; OPTICAL COHERENCE TOMOGRAPHY; PHONATION; PRIORITY JOURNAL; THICKNESS; VOCAL CORD; VOICE;

EID: 33645985824     PISSN: 00034894     EISSN: None     Source Type: Journal    
DOI: 10.1177/000348940611500405     Document Type: Article
Times cited : (43)

References (19)
  • 2
    • 0000242182 scopus 로고
    • Phonosurgery: Basic and clinical investigations
    • Hirano M. Phonosurgery: basic and clinical investigations. Otologica (Fukuoka) 1975;21:239-442.
    • (1975) Otologica (Fukuoka) , vol.21 , pp. 239-442
    • Hirano, M.1
  • 3
    • 0002047831 scopus 로고
    • Structure of the vocal fold in normal and diseased states: Anatomical and physiological studies
    • The American Speech-Language-Hearing Association
    • Hirano M. Structure of the vocal fold in normal and diseased states: anatomical and physiological studies. In: Proceedings of the Conference on the Assessment of Vocal Pathology. The American Speech-Language-Hearing Association, 1981:11-27.
    • (1981) Proceedings of the Conference on the Assessment of Vocal Pathology , pp. 11-27
    • Hirano, M.1
  • 4
    • 0002928575 scopus 로고
    • Phonosurgical anatomy of the larynx
    • Ford C, Bless D, eds. New York, NY: Raven
    • Hirano M. Phonosurgical anatomy of the larynx. In: Ford C, Bless D, eds. Phonosurgery. New York, NY: Raven, 1991:25-41.
    • (1991) Phonosurgery , pp. 25-41
    • Hirano, M.1
  • 6
    • 0026254046 scopus 로고
    • Optical coherence tomography
    • Huang D, Swanson EA, Lin CP, et al. Optical coherence tomography. Science 1991;254:1178-81.
    • (1991) Science , vol.254 , pp. 1178-1181
    • Huang, D.1    Swanson, E.A.2    Lin, C.P.3
  • 7
    • 0035991794 scopus 로고    scopus 로고
    • Clinical imaging with optical coherence tomography
    • Bouma BE, Tearney GJ. Clinical imaging with optical coherence tomography. Acad Radiol 2002;9:942-53.
    • (2002) Acad Radiol , vol.9 , pp. 942-953
    • Bouma, B.E.1    Tearney, G.J.2
  • 9
    • 0036726096 scopus 로고    scopus 로고
    • Simultaneous intensity, birefringence, and flow measurements with high-speed fiber-based optical coherence tomography
    • Pierce MC, Park BH, Cense B, de Boer JF. Simultaneous intensity, birefringence, and flow measurements with high-speed fiber-based optical coherence tomography. Opt Lett 2002;27: 1534-6.
    • (2002) Opt Lett , vol.27 , pp. 1534-1536
    • Pierce, M.C.1    Park, B.H.2    Cense, B.3    De Boer, J.F.4
  • 10
    • 1342292102 scopus 로고    scopus 로고
    • Real-time multifunctional optical coherence tomography
    • Park BH, Pierce MC, Cense B, de Boer JF. Real-time multifunctional optical coherence tomography. Opt Express 2003;11:782-93.
    • (2003) Opt Express , vol.11 , pp. 782-793
    • Park, B.H.1    Pierce, M.C.2    Cense, B.3    De Boer, J.F.4
  • 11
    • 0036629488 scopus 로고    scopus 로고
    • Review of polarization sensitive optical coherence tomography and Stokes vector determination
    • de Boer JF, Milner TE. Review of polarization sensitive optical coherence tomography and Stokes vector determination. J Biomed Opt 2002;7:359-71.
    • (2002) J Biomed Opt , vol.7 , pp. 359-371
    • De Boer, J.F.1    Milner, T.E.2
  • 12
    • 0000063297 scopus 로고    scopus 로고
    • Two-dimensional birefringence imaging in biological tissue by polarization-sensitive optical coherence tomography
    • de Boer JF, Milner TE, van Gemert MJC, Nelson JS. Two-dimensional birefringence imaging in biological tissue by polarization-sensitive optical coherence tomography. Opt Lett 1997;22:934-6.
    • (1997) Opt Lett , vol.22 , pp. 934-936
    • De Boer, J.F.1    Milner, T.E.2    Van Gemert, M.J.C.3    Nelson, J.S.4
  • 13
    • 5644278758 scopus 로고    scopus 로고
    • Capabilities of optical coherence tomography in laryngology
    • Bouma B, Tearney G, eds. Basel, Switzerland: Marcel Dekker
    • Gladkova ND, Shakhov AV, Feldchtein F. Capabilities of optical coherence tomography in laryngology. In: Bouma B, Tearney G, eds. Handbook of optical coherence tomography. Basel, Switzerland: Marcel Dekker, 2002:705-24.
    • (2002) Handbook of Optical Coherence Tomography , pp. 705-724
    • Gladkova, N.D.1    Shakhov, A.V.2    Feldchtein, F.3
  • 15
    • 0034884584 scopus 로고    scopus 로고
    • Optical coherence tomography monitoring for laser surgery of laryngeal carcinoma
    • Shakhov AV, Terentjeva AB, Kamensky VA, et al. Optical coherence tomography monitoring for laser surgery of laryngeal carcinoma. J Surg Oncol 2001;77:253-8.
    • (2001) J Surg Oncol , vol.77 , pp. 253-258
    • Shakhov, A.V.1    Terentjeva, A.B.2    Kamensky, V.A.3
  • 16
    • 0345293363 scopus 로고    scopus 로고
    • OCT imaging of the larynx: A feasibility study
    • Bibas AG, Podoleanu AG, Cucu RG, et al. OCT imaging of the larynx: a feasibility study. Proc SPIE 2003;4956:95-100.
    • (2003) Proc SPIE , vol.4956 , pp. 95-100
    • Bibas, A.G.1    Podoleanu, A.G.2    Cucu, R.G.3
  • 18
    • 0033770533 scopus 로고    scopus 로고
    • Age- and gender-related collagen distribution in human vocal folds
    • Hammond TH, Gray SD, Butler JE. Age- and gender-related collagen distribution in human vocal folds. Ann Otol Rhinol Laryngol 2000;109:913-20.
    • (2000) Ann Otol Rhinol Laryngol , vol.109 , pp. 913-920
    • Hammond, T.H.1    Gray, S.D.2    Butler, J.E.3
  • 19
    • 2442646774 scopus 로고    scopus 로고
    • Polarization-sensitive optical coherence tomography of invasive basal cell carcinoma
    • Strasswimmer J, Pierce MC, Park BH, Neel V, de Boer JF. Polarization-sensitive optical coherence tomography of invasive basal cell carcinoma. J Biomed Opt 2004;9:292-8.
    • (2004) J Biomed Opt , vol.9 , pp. 292-298
    • Strasswimmer, J.1    Pierce, M.C.2    Park, B.H.3    Neel, V.4    De Boer, J.F.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.