메뉴 건너뛰기




Volumn 17, Issue 11, 2005, Pages

"Buddy wire" technique to overcome proximal coronary tortuosity during rotational atherectomy

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTERY CALCIFICATION; ARTICLE; ATHERECTOMY; CASE REPORT; CORONARY ARTERY OBSTRUCTION; CORONARY STENT; DEVICE; GUIDE WIRE; HUMAN; MALE; PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY;

EID: 33645983378     PISSN: 10423931     EISSN: 15572501     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (6)

References (9)
  • 1
    • 0030332237 scopus 로고    scopus 로고
    • Technique and strategy of rotational atherectomy
    • Reisman M. Technique and strategy of rotational atherectomy. Cathet Cardiovasc Diagn 1996;(Suppl 3):2-14.
    • (1996) Cathet Cardiovasc Diagn , Issue.3 SUPPL. , pp. 2-14
    • Reisman, M.1
  • 2
    • 0003113376 scopus 로고
    • Rotational atherectomy followed by adjunct stents: The preferred therapy for calcified large vessels?
    • Mintz GS, Dussaillant GR, Wong SC, et al. Rotational atherectomy followed by adjunct stents: The preferred therapy for calcified large vessels? Circulation 1995;92:329.
    • (1995) Circulation , vol.92 , pp. 329
    • Mintz, G.S.1    Dussaillant, G.R.2    Wong, S.C.3
  • 3
    • 0030339487 scopus 로고    scopus 로고
    • Safety and efficacy of elective stent implantation following rotational atherectomy in large, calcified coronary arteries
    • Hong MK, Mintz GS, Popma JJ, et al. Safety and efficacy of elective stent implantation following rotational atherectomy in large, calcified coronary arteries. Cathet Cardiovasc Diagn 1996; (Suppl 3):000-000.
    • (1996) Cathet Cardiovasc Diagn , Issue.3 SUPPL.
    • Hong, M.K.1    Mintz, G.S.2    Popma, J.J.3
  • 4
    • 0030333177 scopus 로고    scopus 로고
    • Coronary perforation complicating rotational ablation: The US multicenter experience
    • Cohen BM, Weber VJ, Reisman M, et al. Coronary perforation complicating rotational ablation: the US multicenter experience. Cathet Cardiovasc Diagn 1996; (Suppl 3):55-59.
    • (1996) Cathet Cardiovasc Diagn , vol.3 , Issue.SUPPL. , pp. 55-59
    • Cohen, B.M.1    Weber, V.J.2    Reisman, M.3
  • 5
    • 0030331680 scopus 로고    scopus 로고
    • Guidewire bias: Potential source of complications with rotational atherectomy
    • Reisman M, Harms V. Guidewire bias: Potential source of complications with rotational atherectomy. Cathet Cardiovasc Diagn 1996;(Suppl 3):64-68.
    • (1996) Cathet Cardiovasc Diagn , Issue.3 SUPPL. , pp. 64-68
    • Reisman, M.1    Harms, V.2
  • 6
    • 0030447442 scopus 로고    scopus 로고
    • The "furrowing effect": Guidewire-induced "directional" lesion ablation in rotational atherectomy of angulated coronary artery lesions
    • Stuver TP, Ling FS. The "furrowing effect": Guidewire-induced "directional" lesion ablation in rotational atherectomy of angulated coronary artery lesions. Cathet Cardiovasc Diagn 1996;39:385-395.
    • (1996) Cathet Cardiovasc Diagn , vol.39 , pp. 385-395
    • Stuver, T.P.1    Ling, F.S.2
  • 7
    • 0029786711 scopus 로고    scopus 로고
    • Forward slide maneuver: A new method of advancing the rotablator system
    • Raybuck BD. Forward slide maneuver: A new method of advancing the rotablator system. Cathet Cardiovasc Diagn 1996; (Suppl 3):60-63.
    • (1996) Cathet Cardiovasc Diagn , Issue.3 SUPPL. , pp. 60-63
    • Raybuck, B.D.1
  • 8
    • 0026553696 scopus 로고
    • Lesion protection during fixed-wire balloon angioplasty: Use of the "buddy wire" technique and access catheters
    • Selig MB. Lesion protection during fixed-wire balloon angioplasty: Use of the "buddy wire" technique and access catheters. Cathet Cardiovasc Diagn 1992;25:331-335.
    • (1992) Cathet Cardiovasc Diagn , vol.25 , pp. 331-335
    • Selig, M.B.1
  • 9
    • 0036303494 scopus 로고    scopus 로고
    • Guidewire bias in rotational atherectomy in the angled lesion: Evaluation based on the thickness of the ablated intima and media
    • Oishi Y, Okamoto M, Sueda T, et al. Guidewire bias in rotational atherectomy in the angled lesion: Evaluation based on the thickness of the ablated intima and media. Circulation 2002;66:659-664.
    • (2002) Circulation , vol.66 , pp. 659-664
    • Oishi, Y.1    Okamoto, M.2    Sueda, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.