메뉴 건너뛰기




Volumn 78, Issue 3, 2006, Pages 347-351

Photon pencil kernel parameterisation based on beam quality index

Author keywords

Beam quality index; Monitor unit verification; Pencil beam

Indexed keywords

ACCURACY; ARTICLE; DATA BASE; DOSIMETRY; INFORMATION PROCESSING; LIGHT SCATTERING; METHODOLOGY; PARAMETRIC TEST; PHANTOM; PHOTON THERAPY; PRIORITY JOURNAL; QUALITY CONTROL; RADIATION BEAM; RADIATION DEPTH DOSE; TREATMENT PLANNING;

EID: 33645959473     PISSN: 01678140     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.radonc.2006.02.002     Document Type: Article
Times cited : (20)

References (12)
  • 1
    • 0034213481 scopus 로고    scopus 로고
    • The ESTRO-QUALity assurance network (EQUAL)
    • Ferreira I.H., Dutreix A., Bridier A., et al. The ESTRO-QUALity assurance network (EQUAL). Radiother Oncol 55 (2000) 273-284
    • (2000) Radiother Oncol , vol.55 , pp. 273-284
    • Ferreira, I.H.1    Dutreix, A.2    Bridier, A.3
  • 3
    • 0029877777 scopus 로고    scopus 로고
    • Experimental determination of the dose kernel in high-energy X-ray beams
    • Ceberg C.P., Bjärngard B.E., and Zhu T.C. Experimental determination of the dose kernel in high-energy X-ray beams. Med Phys 23 (1996) 505-511
    • (1996) Med Phys , vol.23 , pp. 505-511
    • Ceberg, C.P.1    Bjärngard, B.E.2    Zhu, T.C.3
  • 4
    • 0029874819 scopus 로고    scopus 로고
    • Calculation of the absorbed dose distribution due to irregularly shaped photon beams using pencil beam kernels derived form basic beam data
    • Storchi P., and Woudstra E. Calculation of the absorbed dose distribution due to irregularly shaped photon beams using pencil beam kernels derived form basic beam data. Phys Med Biol 41 (1996) 637-656
    • (1996) Phys Med Biol , vol.41 , pp. 637-656
    • Storchi, P.1    Woudstra, E.2
  • 5
    • 0024441718 scopus 로고
    • Determination of effective bremsstrahlung spectra and electron contamination for photon dose calculations
    • Ahnesjö A., and Andreo P. Determination of effective bremsstrahlung spectra and electron contamination for photon dose calculations. Phys Med Biol 34 (1989) 1451-1464
    • (1989) Phys Med Biol , vol.34 , pp. 1451-1464
    • Ahnesjö, A.1    Andreo, P.2
  • 6
    • 0026750950 scopus 로고
    • A pencil beam model for photon dose calculation
    • Ahnesjö A., Saxner M., and Trepp A. A pencil beam model for photon dose calculation. Med Phys 19 (1992) 263-273
    • (1992) Med Phys , vol.19 , pp. 263-273
    • Ahnesjö, A.1    Saxner, M.2    Trepp, A.3
  • 8
    • 22444431767 scopus 로고    scopus 로고
    • Towards equity in turbulent Europe ESTRO, european cooperation and the european commission
    • Baumann M., and Brada M. Towards equity in turbulent Europe ESTRO, european cooperation and the european commission. Radiother Oncol 75 (2005) 251-252
    • (2005) Radiother Oncol , vol.75 , pp. 251-252
    • Baumann, M.1    Brada, M.2
  • 9
    • 22444446013 scopus 로고    scopus 로고
    • The bright but ephemeral life of a rainbow: a chronicle of seventeen years of intensive ESTRO-EU cooperation
    • Heeren G. The bright but ephemeral life of a rainbow: a chronicle of seventeen years of intensive ESTRO-EU cooperation. Radiother Oncol 75 (2005) 253-257
    • (2005) Radiother Oncol , vol.75 , pp. 253-257
    • Heeren, G.1
  • 10
    • 21144440478 scopus 로고    scopus 로고
    • Beam modeling and verification of a photon beam multisource model
    • Ahnesjö A., Weber L., Murman A., et al. Beam modeling and verification of a photon beam multisource model. Med Phys 32 (2005) 1722-1737
    • (2005) Med Phys , vol.32 , pp. 1722-1737
    • Ahnesjö, A.1    Weber, L.2    Murman, A.3
  • 11
    • 0029930762 scopus 로고    scopus 로고
    • Tissue-phantom ratios from percentage depth doses
    • Bjärngard B.E., Zhu T.C., and Ceberg C. Tissue-phantom ratios from percentage depth doses. Med Phys 23 (1996) 629-634
    • (1996) Med Phys , vol.23 , pp. 629-634
    • Bjärngard, B.E.1    Zhu, T.C.2    Ceberg, C.3
  • 12
    • 0030342762 scopus 로고    scopus 로고
    • The equivalent field method for dose determinations in rectangular fields
    • Day M.J., and Aird E.G. The equivalent field method for dose determinations in rectangular fields. Br J Radiol Suppl 25 (1996) 138-151
    • (1996) Br J Radiol Suppl , vol.25 , pp. 138-151
    • Day, M.J.1    Aird, E.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.