-
1
-
-
0032799995
-
High-dimensional nonlinear image registration using symmetric priors
-
Ashburner J., Andersson J., and Friston K. High-dimensional nonlinear image registration using symmetric priors. Neuroimage 9 (1999) 619-628
-
(1999)
Neuroimage
, vol.9
, pp. 619-628
-
-
Ashburner, J.1
Andersson, J.2
Friston, K.3
-
3
-
-
33645840406
-
-
Bro-Nielsen, M., 1996. Medical image registration and surgery simulation. Ph.D. Thesis, Department of Mathematical Modelling, Technical University of Denmark.
-
-
-
-
4
-
-
84945583262
-
Symmetrization of the non-rigid registration problem using invertion-invariant energies: application to multiple sclerosis
-
Proceedings of the 3rd international conference on medical image computing and computer-assisted intervention MICCAI 2000. Delp S.L., DiGioia A.M., and Jaramaz B. (Eds), Springer, Berlin
-
Cachier P., and Rey D. Symmetrization of the non-rigid registration problem using invertion-invariant energies: application to multiple sclerosis. In: Delp S.L., DiGioia A.M., and Jaramaz B. (Eds). Proceedings of the 3rd international conference on medical image computing and computer-assisted intervention MICCAI 2000. Lecture notes in computer science vol. 1935 (2000), Springer, Berlin 472-481
-
(2000)
Lecture notes in computer science
, vol.1935
, pp. 472-481
-
-
Cachier, P.1
Rey, D.2
-
6
-
-
0023006389
-
-
Dengler, J., 1986. Local motion estimation with the dynamic pyramid. In: Proceedings of the 8th Internattonal Conference on Pattern Recognition, ICPR86, Paris, pp. 1289-1292.
-
-
-
-
7
-
-
84991505464
-
Detecting failure, assessing success
-
Hajnal J.V., Hill D.L.G., and Hawkes D.J. (Eds), CRC Press, Boca Raton, FL
-
Fitzpatrick J.M. Detecting failure, assessing success. In: Hajnal J.V., Hill D.L.G., and Hawkes D.J. (Eds). Medical image registration (2001), CRC Press, Boca Raton, FL 117-142
-
(2001)
Medical image registration
, pp. 117-142
-
-
Fitzpatrick, J.M.1
-
8
-
-
0033701129
-
Performance evaluation of medical image processing algorithms
-
Medical imaging 2000: image processing. Hanson K. (Ed), SPIE Press, Bellingham, WA
-
Gee. Performance evaluation of medical image processing algorithms. In: Hanson K. (Ed). Medical imaging 2000: image processing. Proceedings of SPIE vol. 3979 (2000), SPIE Press, Bellingham, WA 19-27
-
(2000)
Proceedings of SPIE
, vol.3979
, pp. 19-27
-
-
Gee1
-
9
-
-
0004754148
-
Across-modality registration using intensity-based cost functions
-
Bankman I. (Ed), Academic Press, London
-
Hill D.L.G., and Hawkes D.J. Across-modality registration using intensity-based cost functions. In: Bankman I. (Ed). Handbook of medical image processing (1999), Academic Press, London 537-553
-
(1999)
Handbook of medical image processing
, pp. 537-553
-
-
Hill, D.L.G.1
Hawkes, D.J.2
-
10
-
-
84889173716
-
An extensible MRI simulator for post-processing evaluation
-
Lecture notes in computer science, Springer, Berlin
-
Kwan R.-S., Evans A., and Pike G.B. An extensible MRI simulator for post-processing evaluation. Lecture notes in computer science. Visualization in biomedical computing (VBC'96) vol. 1131 (1996), Springer, Berlin 135-140
-
(1996)
Visualization in biomedical computing (VBC'96)
, vol.1131
, pp. 135-140
-
-
Kwan, R.-S.1
Evans, A.2
Pike, G.B.3
-
11
-
-
0142152401
-
Point similarity measure based on mutual information
-
Biomedical image registration. Gee J., Maintz J., and Vannier M. (Eds), Springer, Berlin
-
Rogelj P., and Kovačič S. Point similarity measure based on mutual information. In: Gee J., Maintz J., and Vannier M. (Eds). Biomedical image registration. Lecture notes in computer science (LNCS) vol. 2717 (2003), Springer, Berlin 112-121
-
(2003)
Lecture notes in computer science (LNCS)
, vol.2717
, pp. 112-121
-
-
Rogelj, P.1
Kovačič, S.2
-
12
-
-
10744219620
-
Point similarity measures for non-rigid registration of multi-modal data
-
Rogelj P., Kovačič S., and Gee J. Point similarity measures for non-rigid registration of multi-modal data. Computer Vision and Image Understanding 92 1 (2003) 112-140
-
(2003)
Computer Vision and Image Understanding
, vol.92
, Issue.1
, pp. 112-140
-
-
Rogelj, P.1
Kovačič, S.2
Gee, J.3
-
13
-
-
0038398635
-
Validation of nonrigid image registration using finite-element methods: application to breast MR images
-
Schnabel J.A., Tanner C., Castellano-Smith A.D., Degenhard A., Leach M.O., Hose D.R., Hill D.L.G., and Hawkes D.J. Validation of nonrigid image registration using finite-element methods: application to breast MR images. IEEE Transactions on Medical Imaging 22 3 (2003) 238-247
-
(2003)
IEEE Transactions on Medical Imaging
, vol.22
, Issue.3
, pp. 238-247
-
-
Schnabel, J.A.1
Tanner, C.2
Castellano-Smith, A.D.3
Degenhard, A.4
Leach, M.O.5
Hose, D.R.6
Hill, D.L.G.7
Hawkes, D.J.8
-
14
-
-
0000002989
-
Validation of registration accuracy
-
Bankman I. (Ed), Academic Press, London
-
Woods R. Validation of registration accuracy. In: Bankman I. (Ed). Handbook of medical imaging processing and analysis (1999), Academic Press, London 491-497
-
(1999)
Handbook of medical imaging processing and analysis
, pp. 491-497
-
-
Woods, R.1
|