메뉴 건너뛰기




Volumn 27, Issue 4, 2005, Pages 698-705

Dose determination in ESR dating research

Author keywords

Alanine; Concomitant method; Dating; Dose; Dose determination; EPR; ESR

Indexed keywords

ELECTRON SPIN RESONANCE DATING; GEOCHRONOLOGY; IRRADIATION; RELIABILITY ANALYSIS;

EID: 33645765999     PISSN: 02534967     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (8)

References (6)
  • 1
    • 33645771347 scopus 로고
    • Standard method for using the ferrous sulfate (Fricke) dosimeter to measure absorbed dose in water (GB 139-89)
    • Standards Press of China, Beijing (in Chinese) [S]
    • PANG Rui-cao, ZHANG Yan-li, GAO Jun-cheng, et al. 1989. Standard method for using the ferrous sulfate (Fricke) dosimeter to measure absorbed dose in water (GB 139-89) [S]. Standards Press of China, Beijing (in Chinese).
    • (1989)
    • Pang, R.-C.1    Zhang, Y.-L.2    Gao, J.-C.3
  • 2
    • 33645775888 scopus 로고
    • The use of alanine/ESR dosimeters for dating
    • (in Chinese) [J]
    • GAO Jun-cheng, DU Ya-jing. 1991. The use of alanine/ESR dosimeters for dating [J]. Nuclear Technology, 14(2): 90-93 (in Chinese).
    • (1991) Nuclear Technology , vol.14 , Issue.2 , pp. 90-93
    • Gao, J.-C.1    Du, Y.-J.2
  • 3
    • 0002904367 scopus 로고
    • The use if alanine as a solid dosimeter
    • [J]
    • Bradshaw W W, Cadena D G, Crawford E W, et al. 1962. The use if alanine as a solid dosimeter [J]. Radiat Res. 17(1):11-21.
    • (1962) Radiat Res. , vol.17 , Issue.1 , pp. 11-21
    • Bradshaw, W.W.1    Cadena, D.G.2    Crawford, E.W.3
  • 4
    • 0020331280 scopus 로고
    • Dosimetry by ESR spectroscopy of alanine
    • [J]
    • Regulla D F, Deffer U. 1982. Dosimetry by ESR spectroscopy of alanine [J]. Int J Appl Radiat Isot, 33:1101-1114.
    • (1982) Int J Appl Radiat Isot , vol.33 , pp. 1101-1114
    • Regulla, D.F.1    Deffer, U.2
  • 5
    • 19744375489 scopus 로고    scopus 로고
    • Thin Film Alanine-PE Dosimeter used as Transfer Dosimetry System for electron beam dose measurement
    • [J]
    • Lin M, Li H Z, Chen Y D, et al. 2005. Thin Film Alanine-PE Dosimeter used as Transfer Dosimetry System for electron beam dose measurement [J]. Radiat Phys Chem, 73(5):280-286.
    • (2005) Radiat Phys Chem , vol.73 , Issue.5 , pp. 280-286
    • Lin, M.1    Li, H.Z.2    Chen, Y.D.3
  • 6
    • 3442882464 scopus 로고    scopus 로고
    • Dose intercomparison studies for cobalt Gamma-ray and electron beam irradiation in 2002
    • [J]
    • Lin M, Chen Y D,Cui Y, et al. 2004. Dose intercomparison studies for cobalt Gamma-ray and electron beam irradiation in 2002 [J]. Nuclear Science & Techniques, 15(3):166-173.
    • (2004) Nuclear Science & Techniques , vol.15 , Issue.3 , pp. 166-173
    • Lin, M.1    Chen, Y.D.2    Cui, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.