-
1
-
-
0003816273
-
-
Bilitewski U., and Turner A.P.F. (Eds), Harwood Acad. Publ., The Netherlands
-
In: Bilitewski U., and Turner A.P.F. (Eds). Biosensors for Environmental Monitoring (2000), Harwood Acad. Publ., The Netherlands
-
(2000)
Biosensors for Environmental Monitoring
-
-
-
2
-
-
12444330291
-
Biosensors in clinical chemistry
-
D'Orazio P. Biosensors in clinical chemistry. Clin. Chim. Acta 334 (2003) 41-69
-
(2003)
Clin. Chim. Acta
, vol.334
, pp. 41-69
-
-
D'Orazio, P.1
-
3
-
-
0032508684
-
Bioseparation and bioanalytical techniques in environmental monitoring
-
Emon J.M.V., Gerlach C.L., and Bowman K. Bioseparation and bioanalytical techniques in environmental monitoring. J. Chromatogr. B 715 (1998) 211-228
-
(1998)
J. Chromatogr. B
, vol.715
, pp. 211-228
-
-
Emon, J.M.V.1
Gerlach, C.L.2
Bowman, K.3
-
4
-
-
0035161282
-
Immunosensors-principles and applications to clinical chemistry
-
Luppa P.B., Sokoll L.J., and Chan D.W. Immunosensors-principles and applications to clinical chemistry. Clin. Chim. Acta 314 (2001) 1-26
-
(2001)
Clin. Chim. Acta
, vol.314
, pp. 1-26
-
-
Luppa, P.B.1
Sokoll, L.J.2
Chan, D.W.3
-
6
-
-
0035821445
-
Explosive detection in soil using a field-portable continuous flow immunosensor
-
Gauger P.R., Holt D.B., Patterson C.H., Charles P.T., Lake L.S., and Kusterbeck A.W. Explosive detection in soil using a field-portable continuous flow immunosensor. J. Hazard. Mater. 83 (2001) 51-63
-
(2001)
J. Hazard. Mater.
, vol.83
, pp. 51-63
-
-
Gauger, P.R.1
Holt, D.B.2
Patterson, C.H.3
Charles, P.T.4
Lake, L.S.5
Kusterbeck, A.W.6
-
7
-
-
0037178192
-
A miniature fiber optic surface plasmon resonance sensor for fast detection of staphylococcal enterotoxin B
-
Slavik R., Homola J., and Brynda E. A miniature fiber optic surface plasmon resonance sensor for fast detection of staphylococcal enterotoxin B. Biosens. Bioelectron. 17 (2002) 591-595
-
(2002)
Biosens. Bioelectron.
, vol.17
, pp. 591-595
-
-
Slavik, R.1
Homola, J.2
Brynda, E.3
-
8
-
-
0036253047
-
Miniature surface-plasmon resonance immunosensors-rapid and repetitive procedure
-
Suzuki M., Ozawa F., Sugimoto W., and Aso S. Miniature surface-plasmon resonance immunosensors-rapid and repetitive procedure. Anal. Bioanal. Chem. 372 (2002) 301-304
-
(2002)
Anal. Bioanal. Chem.
, vol.372
, pp. 301-304
-
-
Suzuki, M.1
Ozawa, F.2
Sugimoto, W.3
Aso, S.4
-
9
-
-
0242405803
-
A portable surface plasmon resonance (SPR) sensor system with temperature regulation
-
Naimushin A.N., Soelberg S.D., Bartholomew D.U., Elkind J.L., and Furlong C.E. A portable surface plasmon resonance (SPR) sensor system with temperature regulation. Sens. Actuators B 96 (2003) 253-260
-
(2003)
Sens. Actuators B
, vol.96
, pp. 253-260
-
-
Naimushin, A.N.1
Soelberg, S.D.2
Bartholomew, D.U.3
Elkind, J.L.4
Furlong, C.E.5
-
10
-
-
0036712656
-
Analysis of biomolecular interactions using a miniaturized surface plasmon resonance sensor
-
Whelan R.J., Wohland T., Neumann L., Huang B., Kobilka B.K., and Zare R.N. Analysis of biomolecular interactions using a miniaturized surface plasmon resonance sensor. Anal. Chem. 74 (2002) 4570
-
(2002)
Anal. Chem.
, vol.74
, pp. 4570
-
-
Whelan, R.J.1
Wohland, T.2
Neumann, L.3
Huang, B.4
Kobilka, B.K.5
Zare, R.N.6
-
11
-
-
2342472441
-
-
Ligler S., and Taitt C.A.R. (Eds), Elsevier, The Netherlands
-
Homola J., Yee S., and Myszka D. In: Ligler S., and Taitt C.A.R. (Eds). Surface Plasmon Resonance Biosensors (2002), Elsevier, The Netherlands 207-251
-
(2002)
Surface Plasmon Resonance Biosensors
, pp. 207-251
-
-
Homola, J.1
Yee, S.2
Myszka, D.3
-
12
-
-
0034431122
-
Surface plasmon resonance-based immunoassays
-
Mullett W.M., Lai E.P.C., and Yeung J.M. Surface plasmon resonance-based immunoassays. Methods 22 (2000) 77-91
-
(2000)
Methods
, vol.22
, pp. 77-91
-
-
Mullett, W.M.1
Lai, E.P.C.2
Yeung, J.M.3
-
13
-
-
0035153566
-
Current and emerging commercial optical biosensors
-
Baird C.L., and Myszka D.G. Current and emerging commercial optical biosensors. J. Mol. Recognit. 14 (2001) 261-268
-
(2001)
J. Mol. Recognit.
, vol.14
, pp. 261-268
-
-
Baird, C.L.1
Myszka, D.G.2
-
14
-
-
0242531549
-
Piezoelectric crystal immunosensor for sensitive detection of methamphetamine (stimulant drug) in human urine
-
Miura N., Higobashi H., Sakai G., Takeyasu A., Uda T., and Yamazoe N. Piezoelectric crystal immunosensor for sensitive detection of methamphetamine (stimulant drug) in human urine. Tech. Digest 4-IMCS (1992) 228-231
-
(1992)
Tech. Digest 4-IMCS
, pp. 228-231
-
-
Miura, N.1
Higobashi, H.2
Sakai, G.3
Takeyasu, A.4
Uda, T.5
Yamazoe, N.6
-
15
-
-
0027595130
-
Piezoelectric crystal immunosensor for sensitive detection of methamphetamine (stimulant drug) in human urine
-
Miura N., Higobashi H., Sakai G., Takeyasu A., Uda T., and Yamazoe N. Piezoelectric crystal immunosensor for sensitive detection of methamphetamine (stimulant drug) in human urine. Sens. Actuators B 13-14 (1993) 188-191
-
(1993)
Sens. Actuators B
, vol.13-14
, pp. 188-191
-
-
Miura, N.1
Higobashi, H.2
Sakai, G.3
Takeyasu, A.4
Uda, T.5
Yamazoe, N.6
-
16
-
-
0032663459
-
Highly selective and sensitive SPR immunosensor for detection of methamphetamine
-
Sakai G., Nakata S., Uda T., Miura N., and Yamazoe N. Highly selective and sensitive SPR immunosensor for detection of methamphetamine. Electrochim. Acta 44 (1999) 3754-3849
-
(1999)
Electrochim. Acta
, vol.44
, pp. 3754-3849
-
-
Sakai, G.1
Nakata, S.2
Uda, T.3
Miura, N.4
Yamazoe, N.5
-
17
-
-
0037411525
-
Highly sensitive and selective surface plasmon resonance sensor for detection of sub-ppb levels of benzo[a]pyrene by indirect competitive immunoreaction method
-
Miura N., Sasaki M., Gobi K.V., Kataoka C., and Shoyama Y. Highly sensitive and selective surface plasmon resonance sensor for detection of sub-ppb levels of benzo[a]pyrene by indirect competitive immunoreaction method. Biosens. Bioelectron. 18 (2003) 953-959
-
(2003)
Biosens. Bioelectron.
, vol.18
, pp. 953-959
-
-
Miura, N.1
Sasaki, M.2
Gobi, K.V.3
Kataoka, C.4
Shoyama, Y.5
-
18
-
-
0043175166
-
Sub-ppb level detection of 2-hydroxybiphenyl using portable surface plasmon resonance immunosensor
-
Gobi K.V., Kim S.J., Harada R., and Miura N. Sub-ppb level detection of 2-hydroxybiphenyl using portable surface plasmon resonance immunosensor. Electrochemistry 71 (2003) 430-432
-
(2003)
Electrochemistry
, vol.71
, pp. 430-432
-
-
Gobi, K.V.1
Kim, S.J.2
Harada, R.3
Miura, N.4
-
19
-
-
0037367616
-
Highly sensitive detection of polycyclic aromatic hydrocarbons (PAHs) and association constants of the interaction between PAHs and antibodies using surface plasmon resonance immunosensor
-
Gobi K.V., Sasaki M., Shoyama Y., and Miura N. Highly sensitive detection of polycyclic aromatic hydrocarbons (PAHs) and association constants of the interaction between PAHs and antibodies using surface plasmon resonance immunosensor. Sens. Actuators B 89 (2003) 137-143
-
(2003)
Sens. Actuators B
, vol.89
, pp. 137-143
-
-
Gobi, K.V.1
Sasaki, M.2
Shoyama, Y.3
Miura, N.4
-
20
-
-
12844259636
-
Surface plasmon resonance immunosensor for highly sensitive detection of 2,4,6-trinitrotoluene
-
Shankaran D.R., Gobi K.V., Sakai T., Matsumoto K., Toko K., and Miura N. Surface plasmon resonance immunosensor for highly sensitive detection of 2,4,6-trinitrotoluene. Biosens. Bioelectron. 20 (2005) 1750-1756
-
(2005)
Biosens. Bioelectron.
, vol.20
, pp. 1750-1756
-
-
Shankaran, D.R.1
Gobi, K.V.2
Sakai, T.3
Matsumoto, K.4
Toko, K.5
Miura, N.6
-
21
-
-
4043074764
-
Continuous flow immunosensor for highly selective and real-time detection of sub-ppb levels of 2-hydroxybiphenyl by using surface plasmon resonance imaging
-
Gobi K.V., Tanaka H., Shoyama Y., and Miura N. Continuous flow immunosensor for highly selective and real-time detection of sub-ppb levels of 2-hydroxybiphenyl by using surface plasmon resonance imaging. Biosens. Bioelectron. 20 (2004) 350-357
-
(2004)
Biosens. Bioelectron.
, vol.20
, pp. 350-357
-
-
Gobi, K.V.1
Tanaka, H.2
Shoyama, Y.3
Miura, N.4
-
22
-
-
14744296253
-
Highly sensitive and interference-free simultaneous detection of two polycyclic aromatic hydrocarbons at parts-per-trillion levels using a surface plasmon resonance immunosensor
-
Gobi K.V., and Miura N. Highly sensitive and interference-free simultaneous detection of two polycyclic aromatic hydrocarbons at parts-per-trillion levels using a surface plasmon resonance immunosensor. Sens. Actuators B 103 (2004) 256-271
-
(2004)
Sens. Actuators B
, vol.103
, pp. 256-271
-
-
Gobi, K.V.1
Miura, N.2
-
23
-
-
13844255810
-
Miniaturization in sample treatment for environmental analysis
-
Ramos L., Ramos J.J., and Brinkman U.A.T. Miniaturization in sample treatment for environmental analysis. Anal. Bioanal. Chem. 381 (2005) 119-140
-
(2005)
Anal. Bioanal. Chem.
, vol.381
, pp. 119-140
-
-
Ramos, L.1
Ramos, J.J.2
Brinkman, U.A.T.3
-
24
-
-
0035109041
-
Miniaturization technologies for molecular diagnostics
-
McGlennen R.C. Miniaturization technologies for molecular diagnostics. Clin. Chem. 47 (2001) 393-402
-
(2001)
Clin. Chem.
, vol.47
, pp. 393-402
-
-
McGlennen, R.C.1
-
25
-
-
0033060684
-
Transduction platforms and biointerfacial design of biosensors for real-time biomolecular interaction analysis
-
Quinn J.G., and O'Kennedy R. Transduction platforms and biointerfacial design of biosensors for real-time biomolecular interaction analysis. Anal. Lett. 32 (1999) 1475-1517
-
(1999)
Anal. Lett.
, vol.32
, pp. 1475-1517
-
-
Quinn, J.G.1
O'Kennedy, R.2
-
26
-
-
0034025614
-
The carcinogenicity of the biocide ortho-phenylphenol
-
Appel K.E. The carcinogenicity of the biocide ortho-phenylphenol. Arch. Toxicol. 74 (2000) 61-71
-
(2000)
Arch. Toxicol.
, vol.74
, pp. 61-71
-
-
Appel, K.E.1
-
27
-
-
0032924686
-
Oxidative damage to cellular and isolated DNP by metabolites of a fungicide ortho-phenylphenol
-
Murata M., Moriya K., Inoue S., and Kawanishi S. Oxidative damage to cellular and isolated DNP by metabolites of a fungicide ortho-phenylphenol. Carcinogenesis 20 (1999) 851-857
-
(1999)
Carcinogenesis
, vol.20
, pp. 851-857
-
-
Murata, M.1
Moriya, K.2
Inoue, S.3
Kawanishi, S.4
-
28
-
-
0031825782
-
Toxicological profile for o-phenylphenol and its sodium salt
-
Stouten H. Toxicological profile for o-phenylphenol and its sodium salt. J. Appl. Toxicol. 18 (1998) 261-270
-
(1998)
J. Appl. Toxicol.
, vol.18
, pp. 261-270
-
-
Stouten, H.1
-
29
-
-
0033401027
-
Metabolites of the biocide o-phenylphenol generated oxidative DNA lesions in V 79 cells
-
Henschke P., Almstadt E., Luttgert S., and Appel K.E. Metabolites of the biocide o-phenylphenol generated oxidative DNA lesions in V 79 cells. Arch. Toxicol. 73 (2000) 607-610
-
(2000)
Arch. Toxicol.
, vol.73
, pp. 607-610
-
-
Henschke, P.1
Almstadt, E.2
Luttgert, S.3
Appel, K.E.4
-
30
-
-
0036340268
-
Immunochemical detection of polycyclic aromatic hydrocarbons (PAHs)
-
Fahnrich K.A., Pravda M., and Guilbault G.G. Immunochemical detection of polycyclic aromatic hydrocarbons (PAHs). Anal. Lett. 35 (2002) 1269-1300
-
(2002)
Anal. Lett.
, vol.35
, pp. 1269-1300
-
-
Fahnrich, K.A.1
Pravda, M.2
Guilbault, G.G.3
-
31
-
-
3042777873
-
Biosensors for environmental monitoring of endocrine disruptors: a review article
-
Mozaz S.R., Marco M.P., de Alda M.J.L., and Barcelo D. Biosensors for environmental monitoring of endocrine disruptors: a review article. Anal. Bioanal. Chem. 378 (2004) 588-598
-
(2004)
Anal. Bioanal. Chem.
, vol.378
, pp. 588-598
-
-
Mozaz, S.R.1
Marco, M.P.2
de Alda, M.J.L.3
Barcelo, D.4
-
32
-
-
1642503868
-
Toxicological characteristics of endocrine disrupting chemicals: Developmental toxicity, carcinogenicity and mutagenicity
-
Choi S.M., Yoo S.D., and Lee B.M. Toxicological characteristics of endocrine disrupting chemicals: Developmental toxicity, carcinogenicity and mutagenicity. J. Toxicol. Environ. Health B: Crit. Rev. 7 (2004) 1-32
-
(2004)
J. Toxicol. Environ. Health B: Crit. Rev.
, vol.7
, pp. 1-32
-
-
Choi, S.M.1
Yoo, S.D.2
Lee, B.M.3
-
33
-
-
25144465143
-
Highly sensitive regenerable immunosensor for label-free detection of 2,4-dichlorophenoxyacetic acid at ppb levels by using surface plasmon resonance imaging
-
Gobi K.V., Tanaka H., Shoyama Y., and Miura N. Highly sensitive regenerable immunosensor for label-free detection of 2,4-dichlorophenoxyacetic acid at ppb levels by using surface plasmon resonance imaging. Sens. Actuators B 111-112 (2005) 562-571
-
(2005)
Sens. Actuators B
, vol.111-112
, pp. 562-571
-
-
Gobi, K.V.1
Tanaka, H.2
Shoyama, Y.3
Miura, N.4
-
34
-
-
0037178194
-
Detection of Staphylococcus aureus exterotoxine B at femtomolar levels with a miniature integrated two-channel surface plasmon resonance (SPR) sensor
-
Naimushin A.N., Soelberg S.D., Nguyen D.K., Dunlap L., Bartholomew D., Elkind J., Melendez J., and Furlong C.E. Detection of Staphylococcus aureus exterotoxine B at femtomolar levels with a miniature integrated two-channel surface plasmon resonance (SPR) sensor. Biosens. Bioelectron. 17 (2002) 573-584
-
(2002)
Biosens. Bioelectron.
, vol.17
, pp. 573-584
-
-
Naimushin, A.N.1
Soelberg, S.D.2
Nguyen, D.K.3
Dunlap, L.4
Bartholomew, D.5
Elkind, J.6
Melendez, J.7
Furlong, C.E.8
-
35
-
-
0037023840
-
Spectral surface plasmon resonance biosensor for detection of staphylococcal enterotoxin B in milk
-
Homola J., Dostalek J., Chen S., Rasooly A., Jiang S., and Yee S.S. Spectral surface plasmon resonance biosensor for detection of staphylococcal enterotoxin B in milk. Int. J. Food Microbiol. 75 (2002) 61-69
-
(2002)
Int. J. Food Microbiol.
, vol.75
, pp. 61-69
-
-
Homola, J.1
Dostalek, J.2
Chen, S.3
Rasooly, A.4
Jiang, S.5
Yee, S.S.6
-
36
-
-
21144457783
-
Development of palm-sized differential plasmon resonance meter based on concept of Sprode
-
Hemmi A., Imato T., Aoki Y., Sato M., Soh N., Asano Y., Akasaka C., Okutani S., Ohkubo S., Kaneki N., Shimada K., Eguchi T., and Oinuma T. Development of palm-sized differential plasmon resonance meter based on concept of Sprode. Sens. Actuators B 108 (2005) 893-898
-
(2005)
Sens. Actuators B
, vol.108
, pp. 893-898
-
-
Hemmi, A.1
Imato, T.2
Aoki, Y.3
Sato, M.4
Soh, N.5
Asano, Y.6
Akasaka, C.7
Okutani, S.8
Ohkubo, S.9
Kaneki, N.10
Shimada, K.11
Eguchi, T.12
Oinuma, T.13
|