메뉴 건너뛰기




Volumn 27, Issue 2, 2006, Pages 354-355

Recording CSF pressure with a transducer-tipped wire in an animal model of Chiari I

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ARNOLD CHIARI MALFORMATION; ARTICLE; BALLOON; BALLOON CATHETER; CANNULATION; CATHETERIZATION; CEREBROSPINAL FLUID PRESSURE; CERVICAL SPINE; CONTROLLED STUDY; DOG; ELECTROCARDIOGRAPHY; FLUOROSCOPY; FORAMEN MAGNUM; GUIDE WIRE; NONHUMAN; OXIMETER; POSTERIOR FOSSA; PRESSURE SENSITIVE TRANSDUCER; RECORDER; SENSOR; SUBARACHNOID SPACE; TRANSDUCER; ANASTOMOSIS; ANIMAL; DISEASE MODEL; EQUIPMENT DESIGN; HEART CONTRACTION; INSTRUMENTATION; PATHOPHYSIOLOGY; PHYSIOLOGY; PRESSURE TRANSDUCER; REPRODUCIBILITY; SIGNAL PROCESSING; VERTEBRAL CANAL;

EID: 33645742908     PISSN: 01956108     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (4)

References (4)
  • 1
    • 0027495369 scopus 로고
    • Miniaturized pressure guide-wire: Evaluation in vitro and in isolated hearts
    • Gorge G, Erbel R, Niessing S, et al. Miniaturized pressure guide-wire: evaluation in vitro and in isolated hearts. Cathet Cardiovasc Diagn 1993;30:341-47
    • (1993) Cathet Cardiovasc Diagn , vol.30 , pp. 341-347
    • Gorge, G.1    Erbel, R.2    Niessing, S.3
  • 2
    • 0036193858 scopus 로고    scopus 로고
    • Relationship between pressure-derived collateral blood flow and diabetes mellitus in patients with stable angina pectoris: A study based on coronary pressure measurement
    • Nisanci Y, Sezer M, Umman B, et al. Relationship between pressure-derived collateral blood flow and diabetes mellitus in patients with stable angina pectoris: a study based on coronary pressure measurement. J Invasive Cardiol 2002;14:118-22
    • (2002) J Invasive Cardiol , vol.14 , pp. 118-122
    • Nisanci, Y.1    Sezer, M.2    Umman, B.3
  • 3
    • 0034778542 scopus 로고    scopus 로고
    • Effect of Guglielmi detachable coil placement on intraaneurysmal pressure: Experimental study in canines
    • Sorteberg A, Sorteberg W, Turk AS, et al. Effect of Guglielmi detachable coil placement on intraaneurysmal pressure: experimental study in canines. AJNR Am J Neuroradiol 2001;22:1750-56
    • (2001) AJNR Am J Neuroradiol , vol.22 , pp. 1750-1756
    • Sorteberg, A.1    Sorteberg, W.2    Turk, A.S.3
  • 4
    • 15944366596 scopus 로고    scopus 로고
    • Percutaneous translumbar spinal cord compression injury in dogs from an angioplasty balloon: MR and histopathologic changes with balloon sizes and compression times
    • Purdy PD, White CL 3rd, Baer DL, et al. Percutaneous translumbar spinal cord compression injury in dogs from an angioplasty balloon: MR and histopathologic changes with balloon sizes and compression times. AJNR Am J Neuroradiol 2004;25:1435-42
    • (2004) AJNR Am J Neuroradiol , vol.25 , pp. 1435-1442
    • Purdy, P.D.1    White III, C.L.2    Baer, D.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.