메뉴 건너뛰기




Volumn 52, Issue 1, 2006, Pages 9-16

Artificial heart research and present status of clinical application in Japan

Author keywords

[No Author keywords available]

Indexed keywords

CLINICAL APPLICATION; PEDIATRIC PATIENTS; VENTRICULAR ASSIST DEVICE (VAD);

EID: 33645729279     PISSN: 10582916     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.mat.0000196711.98042.12     Document Type: Article
Times cited : (4)

References (13)
  • 1
    • 0001769834 scopus 로고    scopus 로고
    • Implantable total artificial heart: History and present status at the University of Tokyo
    • Imachi K, Chinzei T, Abe Y, et al: Implantable total artificial heart: History and present status at the University of Tokyo. J Artif Organs 2: 13-23, 1999.
    • (1999) J Artif Organs , vol.2 , pp. 13-23
    • Imachi, K.1    Chinzei, T.2    Abe, Y.3
  • 2
    • 0019757766 scopus 로고
    • Three goats survived for 288 days, 243 days and 232 days with hybrid total artificial heart
    • Atsumi K, Fujimasa I, Imachi K, et al: Three goats survived for 288 days, 243 days and 232 days with hybrid total artificial heart. Trans ASAIO 27: 77-82, 1981.
    • (1981) Trans ASAIO , vol.27 , pp. 77-82
    • Atsumi, K.1    Fujimasa, I.2    Imachi, K.3
  • 3
    • 0005474356 scopus 로고
    • Artificial heart incorporated in the chest
    • Atsumi K, Hori M, Ikeda S, et al: Artificial heart incorporated in the chest. Trans ASAIO 9: 292-297, 1963.
    • (1963) Trans ASAIO , vol.9 , pp. 292-297
    • Atsumi, K.1    Hori, M.2    Ikeda, S.3
  • 4
    • 0005404595 scopus 로고
    • Evaluation of antithrombogenicity, durability and biocompatibility of an artificial heart system for more than 100 days
    • Imachi K, Fujimasa I, Miyake H, et al: Evaluation of antithrombogenicity, durability and biocompatibility of an artificial heart system for more than 100 days. Artif Organs 5: 423-429, 1981.
    • (1981) Artif Organs , vol.5 , pp. 423-429
    • Imachi, K.1    Fujimasa, I.2    Miyake, H.3
  • 5
    • 0023733417 scopus 로고
    • A newly designed jellyfish valve for an artificial heart blood pump
    • Imachi K, Fujimasa I, Mabuchi K, et al: A newly designed jellyfish valve for an artificial heart blood pump. Trans ASAIO 34: 726-728, 1988.
    • (1988) Trans ASAIO , vol.34 , pp. 726-728
    • Imachi, K.1    Fujimasa, I.2    Mabuchi, K.3
  • 6
    • 0035074157 scopus 로고    scopus 로고
    • A new hypothesis on the mechanism of calcification formed on a blood contacted polymer surface
    • Imachi K, Chinzei T, Abe Y, et al: A new hypothesis on the mechanism of calcification formed on a blood contacted polymer surface. J Artif Organs 4: 74-82, 2001.
    • (2001) J Artif Organs , vol.4 , pp. 74-82
    • Imachi, K.1    Chinzei, T.2    Abe, Y.3
  • 7
    • 0034799468 scopus 로고    scopus 로고
    • Design improvement of the jellyfish valve for long-term use in artificial heart
    • Iwasaki K, Umezu M, Imachi K, Fujimoto T: Design improvement of the jellyfish valve for long-term use in artificial heart. IJAO 24: 463-469, 2001.
    • (2001) IJAO , vol.24 , pp. 463-469
    • Iwasaki, K.1    Umezu, M.2    Imachi, K.3    Fujimoto, T.4
  • 8
    • 0016411880 scopus 로고
    • Hemodynamic analysis on prolonged survival cases (30 days and 20 days) of artificial total heart replacement
    • Atsumi K, Sakurai Y, Fujimasa I, et al: Hemodynamic analysis on prolonged survival cases (30 days and 20 days) of artificial total heart replacement. Trans ASAIO 21: 545-554, 1975.
    • (1975) Trans ASAIO , vol.21 , pp. 545-554
    • Atsumi, K.1    Sakurai, Y.2    Fujimasa, I.3
  • 9
    • 0021645494 scopus 로고
    • Overall analysis of the causes of pathophysiological problems in total artificial heart in animals by cardiac receptor hypothesis
    • Imachi K, Fujimasa I, Nakajima M, et al: Overall analysis of the causes of pathophysiological problems in total artificial heart in animals by cardiac receptor hypothesis. Trans ASAIO 30: 591-596, 1984.
    • (1984) Trans ASAIO , vol.30 , pp. 591-596
    • Imachi, K.1    Fujimasa, I.2    Nakajima, M.3
  • 10
    • 0031888725 scopus 로고    scopus 로고
    • Physiological control of a total artificial heart: Conductance and arterial pressure based control
    • Abe Y, Chinzei T, Mabuchi K, et al: Physiological control of a total artificial heart: Conductance and arterial pressure based control. J Appl Physiol 84: 868-876, 1998.
    • (1998) J Appl Physiol , vol.84 , pp. 868-876
    • Abe, Y.1    Chinzei, T.2    Mabuchi, K.3
  • 11
    • 12244300949 scopus 로고    scopus 로고
    • Third model of the undulation pump total artificial heart
    • Abe Y, Chinzei T, Isoyama T, et al: Third model of the undulation pump total artificial heart. ASAIO J 49: 123-127, 2003.
    • (2003) ASAIO J , vol.49 , pp. 123-127
    • Abe, Y.1    Chinzei, T.2    Isoyama, T.3
  • 12
    • 0026564103 scopus 로고
    • Fabrication of a jellyfish valve for use in an artificial heart
    • Imachi K, Mabuchi K, Chinzei T, et al: Fabrication of a jellyfish valve for use in an artificial heart. ASAIO J 38: 237-242, 1992.
    • (1992) ASAIO J , vol.38 , pp. 237-242
    • Imachi, K.1    Mabuchi, K.2    Chinzei, T.3
  • 13
    • 0034427189 scopus 로고    scopus 로고
    • Miniature undulation pump for the study of renal circulation
    • Saito I, Abe Y, Chinzei T, et al: Miniature undulation pump for the study of renal circulation. J Congest Heart Fail Circ Sup 1: 321-325, 2001.
    • (2001) J Congest Heart Fail Circ Sup , vol.1 , pp. 321-325
    • Saito, I.1    Abe, Y.2    Chinzei, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.