메뉴 건너뛰기




Volumn 29, Issue 4, 2006, Pages 429-430

Uncomplicated heart and lung perforation by a displaced ventricular pacemaker lead: A case report

Author keywords

Lead displacement; Lung perforation; Pacemakers

Indexed keywords

ADULT; ANAMNESIS; ARTICLE; CASE REPORT; CLINICAL EXAMINATION; CLINICAL FEATURE; COMPUTER ASSISTED TOMOGRAPHY; DEVICE REMOVAL; ELECTROCARDIOGRAM; FEMALE; HEART MUSCLE INJURY; HUMAN; LUNG INJURY; PACEMAKER FAILURE; PERICARDIAL EFFUSION; PNEUMOTHORAX; SICK SINUS SYNDROME; SURGICAL TECHNIQUE; THORAX RADIOGRAPHY; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; TRANSTHORACIC ECHOCARDIOGRAPHY;

EID: 33645725071     PISSN: 01478389     EISSN: 15408159     Source Type: Journal    
DOI: 10.1111/j.1540-8159.2006.00366.x     Document Type: Article
Times cited : (26)

References (9)
  • 1
    • 0028819419 scopus 로고
    • Low incidence of lead related complications associated with nonthoracotomy implantable cardioverter defibrillator systems
    • Fahy GJ Kleman JM Wilkoff BL et al.. Low incidence of lead related complications associated with nonthoracotomy implantable cardioverter defibrillator systems. Pacing Clin Electrophysiol 1995 18 172 178.
    • (1995) Pacing Clin Electrophysiol , vol.18 , pp. 172-178
    • Fahy, G.J.1    Kleman, J.M.2    Wilkoff, B.L.3
  • 2
    • 0025684580 scopus 로고
    • Analysis of complications of permanent transvenous implantable cardiac pacemaker related to operative and postoperative management in 717 consecutive patients
    • Matsuura Y Yamashina H Higo M et al.. Analysis of complications of permanent transvenous implantable cardiac pacemaker related to operative and postoperative management in 717 consecutive patients. Hiroshima J Med Sci 1990 39 131 137.
    • (1990) Hiroshima J Med Sci , vol.39 , pp. 131-137
    • Matsuura, Y.1    Yamashina, H.2    Higo, M.3
  • 3
    • 0030008104 scopus 로고    scopus 로고
    • Perforation of the right ventricle by transvenous defibrillator leads: Prevention and treatment
    • Molina JE. Perforation of the right ventricle by transvenous defibrillator leads: Prevention and treatment. Pacing Clin Electrophysiol 1996 19 288 292.
    • (1996) Pacing Clin Electrophysiol , vol.19 , pp. 288-292
    • Molina, J.E.1
  • 4
    • 0029907921 scopus 로고    scopus 로고
    • Incidence of perforation and other mechanical complications during dual active fixation
    • Trigano AJ Taramasco V Paganelli F et al.. Incidence of perforation and other mechanical complications during dual active fixation. Pacing Clin Electrophysiol 1996 19 1828 1831.
    • (1996) Pacing Clin Electrophysiol , vol.19 , pp. 1828-1831
    • Trigano, A.J.1    Taramasco, V.2    Paganelli, F.3
  • 6
    • 0024556859 scopus 로고
    • Pacemaker-implantation complication rates: An analysis of some contributing factors
    • Parsonnet V Bernstein AD Lindsay B. Pacemaker-implantation complication rates: An analysis of some contributing factors. J Am Coll Cardiol 1989 13 917 921.
    • (1989) J Am Coll Cardiol , vol.13 , pp. 917-921
    • Parsonnet, V.1    Bernstein, A.D.2    Lindsay, B.3
  • 7
    • 0035167747 scopus 로고    scopus 로고
    • The management of surgical complications of pacemaker and implantable cardioverter-defibrillators
    • Pavia S Wilkoff B. The management of surgical complications of pacemaker and implantable cardioverter-defibrillators. Curr Opin Cardiol 2001 16 66 71.
    • (2001) Curr Opin Cardiol , vol.16 , pp. 66-71
    • Pavia, S.1    Wilkoff, B.2
  • 8
    • 0033869437 scopus 로고    scopus 로고
    • Cardiac tamponade in the "new device" era: Evaluation of 6999 consecutive percutaneous coronary interventions
    • Von Sohsten R Kopistansky C Cohen M et al.. Cardiac tamponade in the "new device" era: Evaluation of 6999 consecutive percutaneous coronary interventions. Am Heart J 2000 140 279 283.
    • (2000) Am Heart J , vol.140 , pp. 279-283
    • Von Sohsten, R.1    Kopistansky, C.2    Cohen, M.3
  • 9
    • 0029959157 scopus 로고    scopus 로고
    • Surgical treatment for right ventricular perforation caused by transvenous pacing electrodes: A report of three cases
    • Asano M Mishima A Ishii T et al.. Surgical treatment for right ventricular perforation caused by transvenous pacing electrodes: A report of three cases. Surg Today 1996 26 933 935.
    • (1996) Surg Today , vol.26 , pp. 933-935
    • Asano, M.1    Mishima, A.2    Ishii, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.