메뉴 건너뛰기




Volumn 53, Issue 1, 2006, Pages 18-24

New approach to obtain high resolution using conventional block designs in PET

Author keywords

Decay time; GSO; High resolution; LSO; LYSO; Positron emission tomography (PET)

Indexed keywords

DECAY TIME; GSO; HIGH RESOLUTION; LSO; LYSO;

EID: 33645669127     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNS.2005.862957     Document Type: Article
Times cited : (10)

References (9)
  • 1
    • 0036816145 scopus 로고    scopus 로고
    • Count rate analysis of PET scanner designs based on a GSO depth of interaction detector with a large-area PS-PMT
    • Oct.
    • K. Kitamura, M. Amano, and H. Murayama, "Count rate analysis of PET scanner designs based on a GSO depth of interaction detector with a large-area PS-PMT," IEEE Trans. Nucl. Sci., vol. 49. no. 5, pp. 2218-2222, Oct. 2002.
    • (2002) IEEE Trans. Nucl. Sci. , vol.49 , Issue.5 , pp. 2218-2222
    • Kitamura, K.1    Amano, M.2    Murayama, H.3
  • 2
    • 0030166382 scopus 로고    scopus 로고
    • Optical fiber readout of scintillator arrays using a multi-channel PMT: A high resolution PET detector for animal imaging
    • Jun.
    • S. R. Cherry, S. Shao, S. Siegel, R. W. Silverman, E. Mumcuoglu, K. Meadors, and M. E. Phelps, "Optical fiber readout of scintillator arrays using a multi-channel PMT: A high resolution PET detector for animal imaging." IEEE Trans. Nucl. Sci., vol. 43. no. 3, pp. 1932-1937, Jun. 1996.
    • (1996) IEEE Trans. Nucl. Sci. , vol.43 , Issue.3 , pp. 1932-1937
    • Cherry, S.R.1    Shao, S.2    Siegel, S.3    Silverman, R.W.4    Mumcuoglu, E.5    Meadors, K.6    Phelps, M.E.7
  • 5
    • 0038382221 scopus 로고    scopus 로고
    • Effects of intercrystal crosstalk on multielement, LSO/APD PET detectors
    • Jun.
    • P. Vaska, S. P. Stoll, C. E. Woddy, D. J. Schlyer, and S. Shokouhi, "Effects of intercrystal crosstalk on multielement, LSO/APD PET detectors," IEEE Trans. Nucl. Sci., vol. 50, no. 3, pp. 362-366, Jun. 2003.
    • (2003) IEEE Trans. Nucl. Sci. , vol.50 , Issue.3 , pp. 362-366
    • Vaska, P.1    Stoll, S.P.2    Woddy, C.E.3    Schlyer, D.J.4    Shokouhi, S.5
  • 6
    • 84939045331 scopus 로고
    • A multicrystal two-dimensional BGO detector system for positron emission tomography
    • M. E. Casey and R. Nutt. "A multicrystal two-dimensional BGO detector system for positron emission tomography." IEEE Trans. Nucl. Sci., vol. NS-33, pp. 460-163, 1986.
    • (1986) IEEE Trans. Nucl. Sci. , vol.NS-33 , pp. 460-1163
    • Casey, M.E.1    Nutt, R.2
  • 7
    • 33645683154 scopus 로고    scopus 로고
    • Method for producing a high resolution detector array, USPTO, 6 749 761, Jun. 15
    • M. S. Andreaco, C. W. Williams, C. J. Moyers, and K. Vaigneur, Method for producing a high resolution detector array, USPTO, 6 749 761, Jun. 15, 2004.
    • (2004)
    • Andreaco, M.S.1    Williams, C.W.2    Moyers, C.J.3    Vaigneur, K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.