메뉴 건너뛰기




Volumn 32, Issue 1, 2006, Pages 62-66

Computer simulation of the U-tube ground heat exchanger for GSHP

Author keywords

Computer simulation; Heat exchanger; Heat pump; Heat transfer

Indexed keywords

BOUNDARY CONDITIONS; COMPUTER SIMULATION; FINITE VOLUME METHOD; HEAT EXCHANGERS; HEAT TRANSFER; MATHEMATICAL MODELS; TEMPERATURE DISTRIBUTION;

EID: 33645636290     PISSN: 02540037     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (4)

References (6)
  • 1
    • 0001848789 scopus 로고
    • Theory of the ground pipe heat source for the heat pump
    • INGERSOLL L R, PASS H J. Theory of the ground pipe heat source for the heat pump[J]. Heating, Piping and Air Conditioning, 1948, 6(1): 119-122.
    • (1948) Heating, Piping and Air Conditioning , vol.6 , Issue.1 , pp. 119-122
    • Ingersoll, L.R.1    Pass, H.J.2
  • 3
    • 0032305923 scopus 로고    scopus 로고
    • Development of an equivalent diameter expression for vertical U-tubes used in ground-coupled heat pumps
    • GU Y, O'NEAL D L. Development of an equivalent diameter expression for vertical U-tubes used in ground-coupled heat pumps[J]. Ashrae Trans, 1998, 104(2): 347-355.
    • (1998) Ashrae Trans , vol.104 , Issue.2 , pp. 347-355
    • Gu, Y.1    O'neal, D.L.2
  • 4
    • 0032446166 scopus 로고    scopus 로고
    • Heat and mass transfer model of a ground heat exchanger: Validation and sensitivity analysis
    • PIECHOWSKI M. Heat and mass transfer model of a ground heat exchanger: validation and sensitivity analysis[J]. International Journal of Energy Research, 1998, 22: 965-979.
    • (1998) International Journal of Energy Research , vol.22 , pp. 965-979
    • Piechowski, M.1
  • 5
    • 0033319374 scopus 로고    scopus 로고
    • A transient two-dimensional finite volume model for the simulation of vertical U-tube ground heat exchangers
    • YAVUZTURK C, SPITLER J D, RESS S J. A transient two-dimensional finite volume model for the simulation of vertical U-tube ground heat exchangers[J]. Ashrae Trans, 1999, 105(2): 465-474.
    • (1999) Ashrae Trans , vol.105 , Issue.2 , pp. 465-474
    • Yavuzturk, C.1    Spitler, J.D.2    Ress, S.J.3
  • 6
    • 0003499798 scopus 로고    scopus 로고
    • New approach for analysis of ground-coil design for applied heat pump systems
    • MEI V C. New approach for analysis of ground-coil design for applied heat pump systems[J]. Ashrae Trans, 1997, 91(2): 1216-1224.
    • (1997) Ashrae Trans , vol.91 , Issue.2 , pp. 1216-1224
    • Mei, V.C.1