메뉴 건너뛰기




Volumn 33, Issue 4, 2006, Pages 968-975

Potential impact of prostate edema on the dosimetry of permanent seed implants using the new 131Cs (model CS-1) seeds

Author keywords

Cesium 131; Implant dosimetry; Interstitial brachytherapy; Prostate edema; Prostate seed implant

Indexed keywords

ERRORS; UROLOGY;

EID: 33645517480     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.2179170     Document Type: Article
Times cited : (24)

References (18)
  • 2
    • 0002527474 scopus 로고
    • Implant therapy for localized prostate cancer
    • M. S.Ernstoff, J. A.Heaney, and R. E.Peschel, in Blackwell Science, Massachusetts
    • J. C. Blasko, P. D. Grimm, H. Ragde, and D. Schumacher, " Implant therapy for localized prostate cancer.. " In, M. S. Ernstoff,,, J. A. Heaney,, and, R. E. Peschel,, in Prostate Cancer (Blackwell Science, Massachusetts, 1988), pp. 137-155.
    • (1988) Prostate Cancer , pp. 137-155
    • Blasko, J.C.1    Grimm, P.D.2    Ragde, H.3    Schumacher, D.4
  • 3
    • 0027483927 scopus 로고
    • Brachytherapy and organ preservation in the management of carcinoma of the prostate
    • J. C. Blasko, P. D. Grimm, and H. Ragde, " Brachytherapy and organ preservation in the management of carcinoma of the prostate.. " Semin. Radiat. Oncol. 3, 240-249 (1993).
    • (1993) Semin. Radiat. Oncol. , vol.3 , pp. 240-249
    • Blasko, J.C.1    Grimm, P.D.2    Ragde, H.3
  • 4
    • 85027230218 scopus 로고    scopus 로고
    • IsoRay Medical Inc., CS-1 Cs131 product information sheet and company website http://www.isoray.com/.
  • 6
    • 0028919251 scopus 로고
    • Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43
    • R. Nath, L. L. Anderson, G. Luxton, K. A. Weaver, J. F. Williamson, and A. S. Meigooni, " Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43., " Med. Phys. 22, 209-234 (1995).
    • (1995) Med. Phys. , vol.22 , pp. 209-234
    • Nath, R.1    Anderson, L.L.2    Luxton, G.3    Weaver, K.A.4    Williamson, J.F.5    Meigooni, A.S.6
  • 7
    • 0037298130 scopus 로고    scopus 로고
    • The determination of radiobologically optimized half-lives for radionuclides used in permanent brachytherapy implants
    • C. I. Armpilia, R. G. Dale, I. P. Coles, B. Jones, and V. Antipas, " The determination of radiobologically optimized half-lives for radionuclides used in permanent brachytherapy implants., " Int. J. Radiat. Oncol., Biol., Phys. 55, 378-385 (2003).
    • (2003) Int. J. Radiat. Oncol., Biol., Phys. , vol.55 , pp. 378-385
    • Armpilia, C.I.1    Dale, R.G.2    Coles, I.P.3    Jones, B.4    Antipas, V.5
  • 9
    • 0032527941 scopus 로고    scopus 로고
    • Edema associated with I-125 or Pd-103 prostate brachytherapy and its impact on postimplant dosimetry: An analysis based on serial CT acquisition
    • F. M. Waterman, N. Yue, B. W. Corn, and A. P. Dicker, " Edema associated with I-125 or Pd-103 prostate brachytherapy and its impact on postimplant dosimetry: An analysis based on serial CT acquisition., " Int. J. Radiat. Oncol., Biol., Phys. 41, 1069-1077 (1998).
    • (1998) Int. J. Radiat. Oncol., Biol., Phys. , vol.41 , pp. 1069-1077
    • Waterman, F.M.1    Yue, N.2    Corn, B.W.3    Dicker, A.P.4
  • 11
    • 0031950541 scopus 로고    scopus 로고
    • Influence of timing on the dosimetric analysis of transperineal ultrasound-guided prostatic conformal brachytherapy
    • G. S. Merrick, W. M. Butler, A. T. Dorsey, and H. L. Walbert, " Influence of timing on the dosimetric analysis of transperineal ultrasound-guided prostatic conformal brachytherapy., " Radiat. Oncol. Invest. 6, 182-190 (1998).
    • (1998) Radiat. Oncol. Invest. , vol.6 , pp. 182-190
    • Merrick, G.S.1    Butler, W.M.2    Dorsey, A.T.3    Walbert, H.L.4
  • 12
    • 0031880062 scopus 로고    scopus 로고
    • Time-dependent changes in CT-based dosimetry of I-125 prostate brachytherapy
    • J. Willins and K. T. Wallner, " Time-dependent changes in CT-based dosimetry of I-125 prostate brachytherapy., " Radiat. Oncol. Invest. 6, 157-160 (1998).
    • (1998) Radiat. Oncol. Invest. , vol.6 , pp. 157-160
    • Willins, J.1    Wallner, K.T.2
  • 13
    • 0032520996 scopus 로고    scopus 로고
    • Timing of computed tomography-based postimplant assessment following permanent transperineal prostate brachytherapy
    • B. R. Prestidge, W. S. Bice, E. J. Kiefer, and J. J. Prete, " Timing of computed tomography-based postimplant assessment following permanent transperineal prostate brachytherapy., " Int. J. Radiat. Oncol., Biol., Phys. 40, 1111-1115 (1998).
    • (1998) Int. J. Radiat. Oncol., Biol., Phys. , vol.40 , pp. 1111-1115
    • Prestidge, B.R.1    Bice, W.S.2    Kiefer, E.J.3    Prete, J.J.4
  • 14
    • 0033556682 scopus 로고    scopus 로고
    • A dynamic model for the estimation of optimum timing of computed tomography scan for dose evaluation of I125 or Pd103 seed implant of prostate
    • N. Yue, A. P. Dicker, B. W. Corn, R. Nath, and F. M. Waterman, " A dynamic model for the estimation of optimum timing of computed tomography scan for dose evaluation of I125 or Pd103 seed implant of prostate., " Int. J. Radiat. Oncol., Biol., Phys. 43, 447-454 (1999).
    • (1999) Int. J. Radiat. Oncol., Biol., Phys. , vol.43 , pp. 447-454
    • Yue, N.1    Dicker, A.P.2    Corn, B.W.3    Nath, R.4    Waterman, F.M.5
  • 15
    • 85027230153 scopus 로고    scopus 로고
    • The impact of edema on planning I125 and Pd103 prostate implant
    • N. Yue, A. P. Dicker, R. Nath, and F. M. Waterman, " The impact of edema on planning I125 and Pd103 prostate implant., " Med. Phys. 26, 760-762 (1998).
    • (1998) Med. Phys. , vol.26 , pp. 760-762
    • Yue, N.1    Dicker, A.P.2    Nath, R.3    Waterman, F.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.