메뉴 건너뛰기




Volumn 11, Issue 2, 2006, Pages 79-83

Estimation of bilirubin using BiliChek™, a transcutaneous bilirubin measurement device: Effects of gestational age and use of phototherapy

Author keywords

Hyperbilirubinemia; Jaundice; Phototherapy; Preterm; Transcutaneous measurement

Indexed keywords

BILIRUBIN;

EID: 33645464262     PISSN: 12057088     EISSN: None     Source Type: Journal    
DOI: 10.1093/pch/11.2.79     Document Type: Article
Times cited : (44)

References (19)
  • 2
    • 0035877811 scopus 로고    scopus 로고
    • Kernicterus in full-term infants - United States, 1994-1998
    • Centers for Disease Control and Prevention. Kernicterus in full-term infants - United States, 1994-1998. MMWR Morb Mortal Wkly Rep 2001;50:491-4.
    • (2001) MMWR Morb Mortal Wkly Rep , vol.50 , pp. 491-494
  • 3
    • 0034909722 scopus 로고    scopus 로고
    • Spectrum of outcome in infants with extreme neonatal jaundice
    • Hanko E, Lindemann R, Hansen TW. Spectrum of outcome in infants with extreme neonatal jaundice. Acta Paediatr 2001;90:782-5.
    • (2001) Acta Paediatr , vol.90 , pp. 782-785
    • Hanko, E.1    Lindemann, R.2    Hansen, T.W.3
  • 4
    • 85039353629 scopus 로고    scopus 로고
    • Management of non-isoimmune hyperbilirubinemia in term neonates with early hospital discharge
    • Abst
    • Faucher DJ, Vallerand D. Management of non-isoimmune hyperbilirubinemia in term neonates with early hospital discharge. Pediatr Res 1999;45:196A. (Abst)
    • (1999) Pediatr Res , vol.45
    • Faucher, D.J.1    Vallerand, D.2
  • 5
    • 3042718933 scopus 로고    scopus 로고
    • Management of hyperbilirubinemia in the newborn infant 35 or more weeks of gestation
    • Erratum in 2004;114:1138
    • American Academy of Pediatrics, Subcommittee on Hyperbilirubinemia. Management of hyperbilirubinemia in the newborn infant 35 or more weeks of gestation. Pediatrics 2004;114:297-316. (Erratum in 2004;114:1138)
    • (2004) Pediatrics , vol.114 , pp. 297-316
  • 6
    • 0025274357 scopus 로고
    • Clinical application of transcutaneous bilirubin measurement. Early prediction of hyperbilirubinemia
    • Yamauchi Y, Yamanouchi I. Clinical application of transcutaneous bilirubin measurement. Early prediction of hyperbilirubinemia. Acta Paediatr Scand 1990;9:385-90.
    • (1990) Acta Paediatr Scand , vol.9 , pp. 385-390
    • Yamauchi, Y.1    Yamanouchi, I.2
  • 8
    • 0034243250 scopus 로고    scopus 로고
    • Noninvasive measurement of total serum bilirubin in a multiracial predischarge newborn population to assess the risk of severe hyperbilirubinemia
    • Bhutani VK, Gourley GR, Adler S, Kreamer B, Dalin C, Johnson LH. Noninvasive measurement of total serum bilirubin in a multiracial predischarge newborn population to assess the risk of severe hyperbilirubinemia. Pediatrics 2000;106:E17.
    • (2000) Pediatrics , vol.106
    • Bhutani, V.K.1    Gourley, G.R.2    Adler, S.3    Kreamer, B.4    Dalin, C.5    Johnson, L.H.6
  • 10
    • 0035009870 scopus 로고    scopus 로고
    • Transcutaneous bilirubin measurement: A multicenter evaluation of a new device
    • Rubaltelli FF, Gourley GR, Loskamp N, et al. Transcutaneous bilirubin measurement: A multicenter evaluation of a new device. Pediatrics 2001;107:1264-71.
    • (2001) Pediatrics , vol.107 , pp. 1264-1271
    • Rubaltelli, F.F.1    Gourley, G.R.2    Loskamp, N.3
  • 11
    • 0037252398 scopus 로고    scopus 로고
    • Transcutaneous bilirubinometry during and after phototherapy
    • Tan K, Dong F. Transcutaneous bilirubinometry during and after phototherapy. Acta Pediatr 2003;92:327-31.
    • (2003) Acta Pediatr , vol.92 , pp. 327-331
    • Tan, K.1    Dong, F.2
  • 12
    • 0030162995 scopus 로고    scopus 로고
    • Validating assessment of neonatal jaundice with transcutaneous bilirubin measurement
    • Ruchala PL, Seibold L, Stremsterfer K. Validating assessment of neonatal jaundice with transcutaneous bilirubin measurement. Neonatal Netw 1996;15:33-7.
    • (1996) Neonatal Netw , vol.15 , pp. 33-37
    • Ruchala, P.L.1    Seibold, L.2    Stremsterfer, K.3
  • 13
    • 0002095419 scopus 로고
    • A perspex icterometer for neonates
    • Gosset IH. A perspex icterometer for neonates. Lancet 1960;1:87-8.
    • (1960) Lancet , vol.1 , pp. 87-88
    • Gosset, I.H.1
  • 14
    • 0342776840 scopus 로고
    • Clinical assessment of depth of jaundice in newborn infants
    • Culley PE, Waterhouse JA, Wood BS. Clinical assessment of depth of jaundice in newborn infants. Lancet 1960;1:88-9.
    • (1960) Lancet , vol.1 , pp. 88-89
    • Culley, P.E.1    Waterhouse, J.A.2    Wood, B.S.3
  • 15
    • 0031789192 scopus 로고    scopus 로고
    • Transcutaneous measurement of hyperbilirubinaemia: Comparison of the Minolta jaundice meter and the Ingram icterometer
    • Bilgen H, Ince Z, Ozek E, Bekiroglu N, Ors R. Transcutaneous measurement of hyperbilirubinaemia: Comparison of the Minolta jaundice meter and the Ingram icterometer. Ann Trop Paediatr 1998;18:325-8.
    • (1998) Ann Trop Paediatr , vol.18 , pp. 325-328
    • Bilgen, H.1    Ince, Z.2    Ozek, E.3    Bekiroglu, N.4    Ors, R.5
  • 16
    • 0021833037 scopus 로고
    • Transcutaneous bilirubinometry: A comparison of old and new methods
    • Schumacher RE, Thornbery JM, Gutcher GR. Transcutaneous bilirubinometry: A comparison of old and new methods. Pediatrics 1985;76:10-4.
    • (1985) Pediatrics , vol.76 , pp. 10-14
    • Schumacher, R.E.1    Thornbery, J.M.2    Gutcher, G.R.3
  • 17
    • 0027474945 scopus 로고
    • Effect of melanin, oxyhemoglobin and bilirubin on transcutaneous bilirubinometry
    • Onks D, Silverman L, Robertson A. Effect of melanin, oxyhemoglobin and bilirubin on transcutaneous bilirubinometry. Acta Pediatr 1993;82:19-21.
    • (1993) Acta Pediatr , vol.82 , pp. 19-21
    • Onks, D.1    Silverman, L.2    Robertson, A.3
  • 18
    • 0036178755 scopus 로고    scopus 로고
    • Improved transcutaneous bilirubinometry: Comparison of SpectR(X) BiliCheck and Minolta Jaundice Meter JM-102 for estimating total serum bilirubin in a normal newborn population
    • Robertson A, Kazmierczak S, Vos P. Improved transcutaneous bilirubinometry: Comparison of SpectR(X) BiliCheck and Minolta Jaundice Meter JM-102 for estimating total serum bilirubin in a normal newborn population. J Perinatol 2002;22:12-4.
    • (2002) J Perinatol , vol.22 , pp. 12-14
    • Robertson, A.1    Kazmierczak, S.2    Vos, P.3
  • 19
    • 0020334617 scopus 로고
    • The Kodak Ektachem clinical chemistry slide for measurement of bilirubin in newboms: Principles and performance
    • Wu TW, Dappen GM, Powers DM, Lo DH, Rand RN, Spayd RW. The Kodak Ektachem clinical chemistry slide for measurement of bilirubin in newboms: Principles and performance. Clin Chem 1982;28:2366-72.
    • (1982) Clin Chem , vol.28 , pp. 2366-2372
    • Wu, T.W.1    Dappen, G.M.2    Powers, D.M.3    Lo, D.H.4    Rand, R.N.5    Spayd, R.W.6