Volumn 47, Issue 13-14, 2006, Pages 1884-1893

Investigation on incomplete condensation of non-azeotropic working fluids in high temperature heat pumps

Author keywords

Experimental research; HTHP; Incomplete condensation; Non azeotropic working fluids

Indexed keywords

CONDENSATION; HEAT TRANSFER; HIGH TEMPERATURE APPLICATIONS;

EID: 33645416094     PISSN: 01968904     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.enconman.2005.09.007     Document Type: Article
Times cited : (12)

References (6)
  • 1
    • 0028712635 scopus 로고
    • Heating-recovery heat pump operating experiences
    • R.L.D. Cane, S.B. Clemes, and D.A. Forgas Heating-recovery heat pump operating experiences ASHRAE Trans 100 2 1994 165 172
    • (1994) ASHRAE Trans , vol.100 , Issue.2 , pp. 165-172
    • Cane, R.L.D.1    Clemes, S.B.2    Forgas, D.A.3
  • 2
    • 0031638329 scopus 로고    scopus 로고
    • Potential of the azeotropic mixtures R22/R142b in high temperature heat pump water heaters with capacity modulation
    • Liebenberg Leon, and Meyer Josua P Potential of the azeotropic mixtures R22/R142b in high temperature heat pump water heaters with capacity modulation ASHRAE Trans 104 1 1998 418 429
    • (1998) ASHRAE Trans , vol.104 , Issue.1 , pp. 418-429
    • Liebenberg, L.1    Meyer, J.P.2
  • 3
    • 38149143190 scopus 로고
    • Thermodynamic screening of some HFCs and HFEs for high-temperature heat pumps as alternative to CFC114
    • D. Sukumar, and V. Rao Pendyala Thermodynamic screening of some HFCs and HFEs for high-temperature heat pumps as alternative to CFC114 Int J Refrig 17 1994 338 342
    • (1994) Int J Refrig , vol.17 , pp. 338-342
    • Sukumar, D.1    Rao Pendyala, V.2
  • 4
    • 0036778846 scopus 로고    scopus 로고
    • High temperature hot water heat pump with non-azeotropic refrigerant mixture HCFC-22/HCFC-141b
    • T.X. Li, K.H. Guo, and R.Z. Wang High temperature hot water heat pump with non-azeotropic refrigerant mixture HCFC-22/HCFC-141b Energ Convers Manage 43 15 2002 2033 2040
    • (2002) Energ Convers Manage , vol.43 , Issue.15 , pp. 2033-2040
    • Li, T.X.1    Guo, K.H.2    Wang, R.Z.3
  • 5
    • 0442280389 scopus 로고    scopus 로고
    • Experimental evaluation of a non-azeotropic working fluid for geothermal heat pump system
    • Li Zhao Experimental evaluation of a non-azeotropic working fluid for geothermal heat pump system Energ Convers Manage 45 9-10 2004 1369 1378
    • (2004) Energ Convers Manage , vol.45 , Issue.9-10 , pp. 1369-1378
    • Li, Z.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.