메뉴 건너뛰기




Volumn 38, Issue 6, 2006, Pages 588-599

A field study of illuminance reduction

Author keywords

Brightness perception; Correlated color temperature; Illuminance; Office; Parabolic louvered luminaire; Task ambient lighting

Indexed keywords

ELECTRIC LIGHTING; ENERGY CONSERVATION; LIGHT SOURCES; OFFICE AUTOMATION; SPARK CHAMBERS; SURVEYS;

EID: 33645389263     PISSN: 03787788     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.enbuild.2005.09.005     Document Type: Article
Times cited : (54)

References (16)
  • 1
    • 0016993973 scopus 로고
    • The integration of task and ambient lighting in office furniture
    • P.L. Shellko, and H.G. Williams The integration of task and ambient lighting in office furniture Lighting Design and Application 6 9 1976 14 23
    • (1976) Lighting Design and Application , vol.6 , Issue.9 , pp. 14-23
    • Shellko, P.L.1    Williams, H.G.2
  • 2
    • 33645389541 scopus 로고
    • The energy effectiveness of task-orientated office lighting systems
    • N. Florence The energy effectiveness of task-orientated office lighting systems Lighting Design and Application 9 1 1978 28 39
    • (1978) Lighting Design and Application , vol.9 , Issue.1 , pp. 28-39
    • Florence, N.1
  • 3
    • 33645415530 scopus 로고
    • Modern office lighting trends in America
    • C.L. Amick Modern office lighting trends in America International Lighting Review 29 2 1978 54 61
    • (1978) International Lighting Review , vol.29 , Issue.2 , pp. 54-61
    • Amick, C.L.1
  • 4
    • 84964169793 scopus 로고
    • Photopic luminance does not always predict perceived room brightness
    • S.M. Berman Photopic luminance does not always predict perceived room brightness Lighting Research and Technology 22 1990 37 41
    • (1990) Lighting Research and Technology , vol.22 , pp. 37-41
    • Berman, S.M.1
  • 5
    • 2742534644 scopus 로고    scopus 로고
    • Chromatic effect of apparent brightness in interior spaces II: SWS lumens model
    • S.A. Fotios Chromatic effect of apparent brightness in interior spaces II: SWS lumens model Lighting Research and Technology 30 1998 103 106
    • (1998) Lighting Research and Technology , vol.30 , pp. 103-106
    • Fotios, S.A.1
  • 8
    • 0040520309 scopus 로고    scopus 로고
    • Effect of sparkling luminous elements on the overall brightness impression: A pilot study
    • Y. Akashi, Y. Tanabe, and I. Akashi Effect of sparkling luminous elements on the overall brightness impression: a pilot study Lighting Research and Technology 32 2000 19 26
    • (2000) Lighting Research and Technology , vol.32 , pp. 19-26
    • Akashi, Y.1    Tanabe, Y.2    Akashi, I.3
  • 10
    • 0037062114 scopus 로고    scopus 로고
    • Does risk homeostasis theory have implications for road safety: For and against
    • G.J.S. Wilde, L.S. Robertson, and I.B. Pless Does risk homeostasis theory have implications for road safety: for and against British Medical Journal 324 7346 2002 1149
    • (2002) British Medical Journal , vol.324 , Issue.7346 , pp. 1149
    • Wilde, G.J.S.1    Robertson, L.S.2    Pless, I.B.3
  • 12
  • 15
    • 15744374446 scopus 로고    scopus 로고
    • Detectability and acceptability of illuminance reduction for load-shedding
    • Y. Akashi, and J. Neches Detectability and acceptability of illuminance reduction for load-shedding Journal of the Illuminating Engineering Society 33 2004 3 13
    • (2004) Journal of the Illuminating Engineering Society , vol.33 , pp. 3-13
    • Akashi, Y.1    Neches, J.2
  • 16
    • 20444424868 scopus 로고    scopus 로고
    • Potential recommendations for illuminance reductions by load-shedding
    • Y. Akashi, and J. Neches Potential recommendations for illuminance reductions by load-shedding Lighting Research and Technology 37 2 2005 133 153
    • (2005) Lighting Research and Technology , vol.37 , Issue.2 , pp. 133-153
    • Akashi, Y.1    Neches, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.