메뉴 건너뛰기




Volumn 55, Issue 2, 2006, Pages 514-520

Capacitive angular-position sensor with electrically floating conductive rotor and measurement redundancy

Author keywords

Angular position sensors; Capacitive sensors; Contactless sensor; Measurement redundancy; Position measurement; Relaxation oscillator

Indexed keywords

ANGLE MEASUREMENT; RELAXATION OSCILLATORS; ROTORS; SENSORS;

EID: 33645310198     PISSN: 00189456     EISSN: None     Source Type: Journal    
DOI: 10.1109/TIM.2006.864243     Document Type: Article
Times cited : (36)

References (11)
  • 1
    • 0141919669 scopus 로고    scopus 로고
    • "Design rules for robust capacitive sensors"
    • Aug
    • G. Brasseur, "Design rules for robust capacitive sensors," IEEE Trans. Instrum. Meas., vol. 52, no. 4, pp. 1261-1265, Aug. 2003.
    • (2003) IEEE Trans. Instrum. Meas. , vol.52 , Issue.4 , pp. 1261-1265
    • Brasseur, G.1
  • 2
    • 0028729626 scopus 로고
    • "The use of capacitance in the measurement of angular and linear displacement"
    • Dec
    • A. H. Falkner, "The use of capacitance in the measurement of angular and linear displacement," IEEE Trans. Instrum. Meas., vol. 43, no. 6, pp. 939-942, Dec. 1994.
    • (1994) IEEE Trans. Instrum. Meas. , vol.43 , Issue.6 , pp. 939-942
    • Falkner, A.H.1
  • 4
    • 0031988251 scopus 로고    scopus 로고
    • "A capacitive 4 turn angular position sensor"
    • Feb
    • G. Brasseur, "A capacitive 4 turn angular position sensor," IEEE Trans. Instrum. Meas., vol. 47, no. 1, pp. 275-279, Feb. 1998.
    • (1998) IEEE Trans. Instrum. Meas. , vol.47 , Issue.1 , pp. 275-279
    • Brasseur, G.1
  • 5
    • 0030126985 scopus 로고    scopus 로고
    • "An accurate low-cost capacitive absolute angular-position sensor with a full-circle range"
    • Apr
    • X. Li, G. C. M. Meijer, G. W. de Jong, and J. W. Spronck, "An accurate low-cost capacitive absolute angular-position sensor with a full-circle range," IEEE Trans. Instrum. Meas., vol. 45, no. 2, pp. 516-520, Apr. 1996.
    • (1996) IEEE Trans. Instrum. Meas. , vol.45 , Issue.2 , pp. 516-520
    • Li, X.1    Meijer, G.C.M.2    de Jong, G.W.3    Spronck, J.W.4
  • 7
    • 0034294103 scopus 로고    scopus 로고
    • "Virtual rotor grounding of capacitive angular position sensors"
    • Oct
    • G. Brasseur, P. L. Fulmek, and W. Smetana, "Virtual rotor grounding of capacitive angular position sensors," IEEE Trans. Instrum. Meas., vol. 49, no. 5, pp. 1108-1111, Oct. 2000.
    • (2000) IEEE Trans. Instrum. Meas. , vol.49 , Issue.5 , pp. 1108-1111
    • Brasseur, G.1    Fulmek, P.L.2    Smetana, W.3
  • 10
    • 0031988215 scopus 로고    scopus 로고
    • "A relaxation-oscillator-based interface for high-accuracy ratiometric signal processing of differential-capacitance transducers"
    • Feb
    • K. Mochizuki, K. Watanabe, T. Masuda, and M. Katsura, "A relaxation-oscillator-based interface for high-accuracy ratiometric signal processing of differential-capacitance transducers," IEEE Trans. Instrum. Meas., vol. 47, no. 1, pp. 11-15, Feb. 1998.
    • (1998) IEEE Trans. Instrum. Meas. , vol.47 , Issue.1 , pp. 11-15
    • Mochizuki, K.1    Watanabe, K.2    Masuda, T.3    Katsura, M.4
  • 11
    • 0030088227 scopus 로고    scopus 로고
    • "Hardware design of electrical capacitance tomography system"
    • Mar
    • W. Q. Yang, "Hardware design of electrical capacitance tomography system," Meas. Sci. Technol., vol. 7, no. 3, pp. 225-232, Mar. 1996.
    • (1996) Meas. Sci. Technol. , vol.7 , Issue.3 , pp. 225-232
    • Yang, W.Q.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.