메뉴 건너뛰기




Volumn 28, Issue 10, 2005, Pages 1047-1051

Recurrence of atrial tachyarrhythmias in implantable cardioverter- defibrillator recipients

Author keywords

Atrial arrhythmia; Implantable cardioverter defibrillator; Therapy

Indexed keywords

AMIODARONE; ANTIARRHYTHMIC AGENT; BETA ADRENERGIC RECEPTOR BLOCKING AGENT; CALCIUM CHANNEL BLOCKING AGENT; DIGOXIN; SOTALOL;

EID: 33645249774     PISSN: 01478389     EISSN: 15408159     Source Type: Journal    
DOI: 10.1111/j.1540-8159.2005.00222.x     Document Type: Article
Times cited : (4)

References (9)
  • 1
    • 0028921708 scopus 로고
    • Prevalence, age distribution, and gender of patients with atrial fibrillation: Analysis and implications
    • Feinberg WM, Blackshear JL, Laupacis A, Kronmal R, Hart RG. Prevalence, age distribution, and gender of patients with atrial fibrillation: Analysis and implications. Arch Intern Med 1995 155 : 469 473.
    • (1995) Arch Intern Med , vol.155 , pp. 469-473
    • Feinberg, W.M.1    Blackshear, J.L.2    Laupacis, A.3    Kronmal, R.4    Hart, R.G.5
  • 3
    • 0028299731 scopus 로고
    • Independent risk factors for atrial fibrillation in a population-based cohort: The Framingham Heart Study
    • Benjamin EJ, Levy D, Vaziri SM, D'Agostino RB, Belanger AJ, Wolf PA. Independent risk factors for atrial fibrillation in a population-based cohort: The Framingham Heart Study. JAMA 1994 271 : 840 844.
    • (1994) JAMA , vol.271 , pp. 840-844
    • Benjamin, E.J.1    Levy, D.2    Vaziri, S.M.3    D'Agostino, R.B.4    Belanger, A.J.5    Wolf, P.A.6
  • 6
    • 0035928755 scopus 로고    scopus 로고
    • Efficacy of pacing therapies for treating atrial tachyarrhythmias in patients with ventricular arrhythmias receiving a dual-chamber implantable cardioverter defibrillator
    • Adler SW II., Wolpert C, Warman EN, Musley SK, Koehler JL, Euler DE. Efficacy of pacing therapies for treating atrial tachyarrhythmias in patients with ventricular arrhythmias receiving a dual-chamber implantable cardioverter defibrillator. Circulation 2001 104 : 887 892.
    • (2001) Circulation , vol.104 , pp. 887-892
    • Adler, I.I.S.W.1    Wolpert, C.2    Warman, E.N.3    Musley, S.K.4    Koehler, J.L.5    Euler, D.E.6
  • 7
    • 0037032207 scopus 로고    scopus 로고
    • Safety and efficacy of advanced atrial pacing therapies for atrial tachyarrhythmias in patients with a new implantable dual chamber cardioverter-debrillator
    • for the GEM III AT Worldwide Investigators.
    • Gillis AM, Unterberg-Buchwald C, Schmidinger H, Massimo S, Wolfe K, Kavaney DJ, Otterness MF, Hohnloser SH, for the GEM III AT Worldwide Investigators. Safety and efficacy of advanced atrial pacing therapies for atrial tachyarrhythmias in patients with a new implantable dual chamber cardioverter-debrillator. J Am Coll Cardiol 2002 40 : 1653 1659.
    • (2002) J Am Coll Cardiol , vol.40 , pp. 1653-1659
    • Gillis, A.M.1    Unterberg-Buchwald, C.2    Schmidinger, H.3    Massimo, S.4    Wolfe, K.5    Kavaney, D.J.6    Otterness, M.F.7    Hohnloser, S.H.8
  • 8
    • 0032924889 scopus 로고    scopus 로고
    • The potential usage of dual chamber pacing in patients with implantable cardioverter defibrillators
    • Best PJ, Hayes DL, Stanton MS. The potential usage of dual chamber pacing in patients with implantable cardioverter defibrillators. Pacing Clin Electrophysiol 1999 22 : 79 85.
    • (1999) Pacing Clin Electrophysiol , vol.22 , pp. 79-85
    • Best, P.J.1    Hayes, D.L.2    Stanton, M.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.