메뉴 건너뛰기




Volumn 117, Issue 1-3, 2006, Pages 231-235

Radiation dose levels during interventional cardiology procedures in a tertiary care hospital

Author keywords

[No Author keywords available]

Indexed keywords

ANGIOCARDIOGRAPHY; ARTICLE; BELGIUM; CARDIOLOGY; CONTROLLED STUDY; CORONARY STENT; DOSIMETRY; ELECTIVE SURGERY; HEART CATHETERIZATION; HUMAN; IMAGE ANALYSIS; INTERVENTIONAL CARDIOVASCULAR PROCEDURE; INTERVENTIONAL RADIOLOGY; PROSPECTIVE STUDY; RADIATION DOSE; RADIATION EXPOSURE; RADIATION MEASUREMENT; RADIOFREQUENCY ABLATION; REFERENCE VALUE; SURGICAL PATIENT; TERTIARY HEALTH CARE; TRANSLUMINAL CORONARY ANGIOPLASTY; UNIVERSITY HOSPITAL;

EID: 33645213720     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/rpd/nci754     Document Type: Article
Times cited : (15)

References (11)
  • 1
    • 0028185452 scopus 로고
    • Potential biological effects following high X ray dose interventional procedures
    • Wagner, L. K., Eifel, P. J. and Geise, R. A. Potential biological effects following high X ray dose interventional procedures. J. Vasc. Interv. Radiol. 5, 71-84 (1994).
    • (1994) J. Vasc. Interv. Radiol , vol.5 , pp. 71-84
    • Wagner, L.K.1    Eifel, P.J.2    Geise, R.A.3
  • 2
    • 0003483454 scopus 로고    scopus 로고
    • Radiological protection and safety in medicine
    • International Commission on Radiological Protection. ICRP Publication 73 (Oxford: Elsevier)
    • International Commission on Radiological Protection. Radiological protection and safety in medicine. ICRP Publication 73 (Oxford: Elsevier) (1996).
    • (1996)
  • 4
    • 0030983107 scopus 로고    scopus 로고
    • Radiation exposure to patients and operators during diagnostic catheterisation and coronary angioplasty
    • Zorzetto, M., Bernardi, G., Morocutti, G. and Fontanelli, A. Radiation exposure to patients and operators during diagnostic catheterisation and coronary angioplasty. Cathet. Cardiovasc. Diagn. 40, 348-351 (1997).
    • (1997) Cathet. Cardiovasc. Diagn. , vol.40 , pp. 348-351
    • Zorzetto, M.1    Bernardi, G.2    Morocutti, G.3    Fontanelli, A.4
  • 5
    • 0033009531 scopus 로고    scopus 로고
    • Chronic radiodermatitis following cardiac catheterisation: A report of two cases and a brief review of the literature
    • Dehen, L., Wilmer, C., Humilière, C., Corcos, T., Pentousis, D., Ollivaud, L., Chatelain, D. and Dubertret, L. Chronic radiodermatitis following cardiac catheterisation: a report of two cases and a brief review of the literature. Heart 81, 308-312 (1999).
    • (1999) Heart , vol.81 , pp. 308-312
    • Dehen, L.1    Wilmer, C.2    Humilière, C.3    Corcos, T.4    Pentousis, D.5    Ollivaud, L.6    Chatelain, D.7    Dubertret, L.8
  • 7
    • 0032427374 scopus 로고    scopus 로고
    • Optimisation in coronary angiography and percutaneous transluminal coronary angioplasty
    • Padovani, R., Novario, R. and Bernardi, G. Optimisation in coronary angiography and percutaneous transluminal coronary angioplasty. Radiat. Prot. Dosim, 80, 303-306 (1998).
    • (1998) Radiat. Prot. Dosim , vol.80 , pp. 303-306
    • Padovani, R.1    Novario, R.2    Bernardi, G.3
  • 8
    • 0030955532 scopus 로고    scopus 로고
    • The impact of cardiology on the collective effective dose in the North of England
    • Broadhead, D. A., Chapple, C.-L., Faulkner, K., Davies, M. L. and McCallum, H. The impact of cardiology on the collective effective dose in the North of England. Br. J. Radiol. 70, 492-497 (1997).
    • (1997) Br. J. Radiol. , vol.70 , pp. 492-497
    • Broadhead, D.A.1    Chapple, C.-L.2    Faulkner, K.3    Davies, M.L.4    McCallum, H.5
  • 9
    • 0036224440 scopus 로고    scopus 로고
    • X ray dose and associated risks from radiofrequency catheter ablation procedures
    • McFadden, S. L., Mooney, R. B. and Shepherd, P. H. X ray dose and associated risks from radiofrequency catheter ablation procedures. Br. J. Radiol. 75, 253-265 (2002).
    • (2002) Br. J. Radiol. , vol.75 , pp. 253-265
    • McFadden, S.L.1    Mooney, R.B.2    Shepherd, P.H.3
  • 10
    • 0025720028 scopus 로고
    • Radiation exposure during radiofrequency catheter ablation of accessory atrioventricular connections
    • Calkins, H., Niklason, L., Sousa, J., El-Atassi, R. and Langberg, J. Radiation exposure during radiofrequency catheter ablation of accessory atrioventricular connections. Circulation 84, 2376-2382 (1991).
    • (1991) Circulation , vol.84 , pp. 2376-2382
    • Calkins, H.1    Niklason, L.2    Sousa, J.3    El-Atassi, R.4    Langberg, J.5
  • 11
    • 0026751433 scopus 로고
    • Radiation exposure to patients and medical personnel during radiofrequency catheter ablation for supraventricular tachicardia
    • Lindsay, B. D., Eichling, J. O., Ambos, H. D. and Cain, M. E. Radiation exposure to patients and medical personnel during radiofrequency catheter ablation for supraventricular tachicardia. Am. J. Cardiol. 70(2), 218-223 (1992).
    • (1992) Am. J. Cardiol. , vol.70 , Issue.2 , pp. 218-223
    • Lindsay, B.D.1    Eichling, J.O.2    Ambos, H.D.3    Cain, M.E.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.