메뉴 건너뛰기




Volumn 29, Issue 2, 2006, Pages 114-117

Virtual placement of posterior C1-C2 transarticular screw fixation

Author keywords

3D model; Atlantoaxial instability; Transarticular screw fixation; Virtual screw placement

Indexed keywords

ADOLESCENT; ADULT; ARTICLE; ATLANTOAXIAL JOINT; BONE SCREW; CERVICAL SPINE; CLINICAL ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; FEMALE; HUMAN; MALE; MEDICAL LITERATURE; PRACTICE GUIDELINE; PRIORITY JOURNAL; SURGICAL APPROACH; VERTEBRAL ARTERY; VERTEBRAL CANAL; VIRTUAL REALITY;

EID: 33645212265     PISSN: 03445607     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10143-005-0003-7     Document Type: Article
Times cited : (13)

References (24)
  • 1
    • 0034866583 scopus 로고    scopus 로고
    • Effect of frameless stereotaxy on the accuracy of C1-2 transarticular screw placement
    • Bloch O, Holly LT, Park J, Obasi C, Kim K, Johnsom JP (2001) Effect of frameless stereotaxy on the accuracy of C1-2 transarticular screw placement. J Neurosurg 95:74-79
    • (2001) J Neurosurg , vol.95 , pp. 74-79
    • Bloch, O.1    Holly, L.T.2    Park, J.3    Obasi, C.4    Kim, K.5    Johnsom, J.P.6
  • 2
    • 0033015069 scopus 로고    scopus 로고
    • Posterior transarticular screw fixation in the treatment of displaced type II odontoid fractures in the geriatric population: Review of seven cases
    • Campanelli M, Kattner KA, Stroink A, Gupta K, West S (1999) Posterior transarticular screw fixation in the treatment of displaced type II odontoid fractures in the geriatric population: review of seven cases. Surg Neurol 5:596-600
    • (1999) Surg Neurol , vol.5 , pp. 596-600
    • Campanelli, M.1    Kattner, K.A.2    Stroink, A.3    Gupta, K.4    West, S.5
  • 4
    • 0029589499 scopus 로고
    • Cannulated screws for odontoid screw fixation and atlantoaxial transarticular screw fixation. Technical note
    • Dickmann CA, Foley KT, Sonntag VK, Smith MM (1995) Cannulated screws for odontoid screw fixation and atlantoaxial transarticular screw fixation. Technical note. J Neurosurg 83:1095-1100
    • (1995) J Neurosurg , vol.83 , pp. 1095-1100
    • Dickmann, C.A.1    Foley, K.T.2    Sonntag, V.K.3    Smith, M.M.4
  • 5
    • 0031927701 scopus 로고    scopus 로고
    • Posterior C1-C2 transarticular screw fixation for atlantoaxial arthrodesis
    • Dickmann CA, Sonntag VK (1998) Posterior C1-C2 transarticular screw fixation for atlantoaxial arthrodesis. Neurosurgery 43:275-280
    • (1998) Neurosurgery , vol.43 , pp. 275-280
    • Dickmann, C.A.1    Sonntag, V.K.2
  • 6
    • 0034128001 scopus 로고    scopus 로고
    • The optimal transarticular C1-2 screw length and the location of the hypoglossal nerve
    • Ebraheim NA, Misson JR, Xu R, Yeasting RA (2000) The optimal transarticular C1-2 screw length and the location of the hypoglossal nerve. Surg Neurol 53:208-210
    • (2000) Surg Neurol , vol.53 , pp. 208-210
    • Ebraheim, N.A.1    Misson, J.R.2    Xu, R.3    Yeasting, R.A.4
  • 7
    • 0032985799 scopus 로고    scopus 로고
    • Modified Gallie technique versus transarticular screw fixation in C1-C2 fusion
    • Farey ID, Nadkarni S, Smith N (1999) Modified Gallie technique versus transarticular screw fixation in C1-C2 fusion. Clin Orthop 35:126-135
    • (1999) Clin Orthop , vol.35 , pp. 126-135
    • Farey, I.D.1    Nadkarni, S.2    Smith, N.3
  • 8
    • 0026694623 scopus 로고
    • Biomechanical evaluation of four different posterior atlantoaxial fixation techniques
    • Grob D, Crisco JJ III, Panjabi MM, Wang P, Dvorak J (1992) Biomechanical evaluation of four different posterior atlantoaxial fixation techniques. Spine 17:480-490
    • (1992) Spine , vol.17 , pp. 480-490
    • Grob, D.1    Crisco III, J.J.2    Panjabi, M.M.3    Wang, P.4    Dvorak, J.5
  • 11
    • 0034669440 scopus 로고    scopus 로고
    • Biomechanical comparison of five different atlantoaxial posterior fixation techniques
    • Henriques T, Cunningham BW, Olerud C, Shimamoto N, Lee GA, Larsson S (2000) Biomechanical comparison of five different atlantoaxial posterior fixation techniques. Spine 25:2877-2883
    • (2000) Spine , vol.25 , pp. 2877-2883
    • Henriques, T.1    Cunningham, B.W.2    Olerud, C.3    Shimamoto, N.4    Lee, G.A.5    Larsson, S.6
  • 13
    • 0030973318 scopus 로고    scopus 로고
    • Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique
    • Madawi AA, Casey TH, Solanki GA, Tuite G, Veres R, Crockard HA (1997) Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique. J Neurosurg 86:961-968
    • (1997) J Neurosurg , vol.86 , pp. 961-968
    • Madawi, A.A.1    Casey, T.H.2    Solanki, G.A.3    Tuite, G.4    Veres, R.5    Crockard, H.A.6
  • 14
    • 0002257576 scopus 로고
    • Stable posterior fusion of the atlas and axis by transarticular screw fixation
    • Kehr P, Weidner A (eds) Springer, Berlin Heidelberg New York
    • Magerl F, Seemann PS (1987) Stable posterior fusion of the atlas and axis by transarticular screw fixation. In: Kehr P, Weidner A (eds) Cervical spine I. Springer, Berlin Heidelberg New York, pp 322-327
    • (1987) Cervical Spine I , pp. 322-327
    • Magerl, F.1    Seemann, P.S.2
  • 15
    • 0033193322 scopus 로고    scopus 로고
    • Biomechanical study of atlantoaxial arthrodesis: Transarticular screw fixation versus modified Brooks posterior wiring
    • Mitchell TC, Sadasivan AL, Ogden AL, Mayeux RH, Mukherjee DP, Albright JA (1999) Biomechanical study of atlantoaxial arthrodesis: transarticular screw fixation versus modified Brooks posterior wiring. J Orthop Trauma 13:483-489
    • (1999) J Orthop Trauma , vol.13 , pp. 483-489
    • Mitchell, T.C.1    Sadasivan, A.L.2    Ogden, A.L.3    Mayeux, R.H.4    Mukherjee, D.P.5    Albright, J.A.6
  • 16
    • 0032530291 scopus 로고    scopus 로고
    • Biomechanical comparison of C1-C2 posterior fixations. Cable, graft, and screw combinations
    • Naderi S, Crawford NR, Song GS, Sonntag VK, Dickmann CA (1998) Biomechanical comparison of C1-C2 posterior fixations. Cable, graft, and screw combinations. Spine 23:1946-1955
    • (1998) Spine , vol.23 , pp. 1946-1955
    • Naderi, S.1    Crawford, N.R.2    Song, G.S.3    Sonntag, V.K.4    Dickmann, C.A.5
  • 17
    • 0032750036 scopus 로고    scopus 로고
    • Biomechanical evaluation of five different occipito-atlanto-axial fixation techniques
    • Oda I, Abumi K, Sell LC, Haggerty CJ, Cunningham BW, McAfee PC (1999) Biomechanical evaluation of five different occipito-atlanto-axial fixation techniques. Spine 24:2377-2382
    • (1999) Spine , vol.24 , pp. 2377-2382
    • Oda, I.1    Abumi, K.2    Sell, L.C.3    Haggerty, C.J.4    Cunningham, B.W.5    McAfee, P.C.6
  • 18
    • 0029773340 scopus 로고    scopus 로고
    • The anatomical suitability of the C1-2 complex for transarticular screw fixation
    • Paramore CG, Dickmann CA, Sonntag VKH (1996)The anatomical suitability of the C1-2 complex for transarticular screw fixation. J Neurosurg 85:221-224
    • (1996) J Neurosurg , vol.85 , pp. 221-224
    • Paramore, C.G.1    Dickmann, C.A.2    Sonntag, V.K.H.3
  • 19
    • 0037102598 scopus 로고    scopus 로고
    • Posterior atlantoaxial fixation: Biomechanical in vitro comparison of six different techniques
    • Richter M, Schmidt R, Claes L, Puhl W, Wilke HJ (2002) Posterior atlantoaxial fixation: biomechanical in vitro comparison of six different techniques. Spine 27:1724-1732
    • (2002) Spine , vol.27 , pp. 1724-1732
    • Richter, M.1    Schmidt, R.2    Claes, L.3    Puhl, W.4    Wilke, H.J.5
  • 20
    • 2942517572 scopus 로고    scopus 로고
    • Case-control study comparing the efficacy of surgical techniques for C1-C2 arthrodesis
    • Taggard DA, Kraut MA, Clark CR, Traynelis VC (2004) Case-control study comparing the efficacy of surgical techniques for C1-C2 arthrodesis. J Spinal Disord Tech 17:189-194
    • (2004) J Spinal Disord Tech , vol.17 , pp. 189-194
    • Taggard, D.A.1    Kraut, M.A.2    Clark, C.R.3    Traynelis, V.C.4
  • 22
    • 0034667351 scopus 로고    scopus 로고
    • Modification of C1-C2 transarticular screw fixation by image-guided surgery
    • Weidner A, Wähler M, Chiu ST, Ulrich C (2000) Modification of C1-C2 transarticular screw fixation by image-guided surgery. Spine 25:2667-2674
    • (2000) Spine , vol.25 , pp. 2667-2674
    • Weidner, A.1    Wähler, M.2    Chiu, S.T.3    Ulrich, C.4
  • 23
    • 0026440731 scopus 로고
    • In vitro investigations of internal fixation systems of the upper cervical spine: Stability of posterior atlanto-axial fixation techniques
    • Wilke H-J, Fischer K, Kugler A, Magerl F, Claes I, Worsdorfer O (1992) In vitro investigations of internal fixation systems of the upper cervical spine: stability of posterior atlanto-axial fixation techniques. Eur Spine J 1:191-199
    • (1992) Eur Spine J , vol.1 , pp. 191-199
    • Wilke, H.-J.1    Fischer, K.2    Kugler, A.3    Magerl, F.4    Claes, I.5    Worsdorfer, O.6
  • 24
    • 0031896021 scopus 로고    scopus 로고
    • Vertebral artery injury in C1-2 transarticular screw fixation: Results of a survey of the AANS/ CNS Section on Disorders of the Spine and peripheral nerves
    • Wright NM, Lauryssen C (1998) Vertebral artery injury in C1-2 transarticular screw fixation: results of a survey of the AANS/ CNS Section on Disorders of the Spine and peripheral nerves. J Neurosurg 88:634-664
    • (1998) J Neurosurg , vol.88 , pp. 634-664
    • Wright, N.M.1    Lauryssen, C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.