메뉴 건너뛰기




Volumn 10, Issue 3, 2006, Pages 256-258

The bleach microscopy method and case detection for tuberculosis control

Author keywords

Bleach; Diagnosis; Hypochlorite; Microscopy; Sputum; Tuberculosis

Indexed keywords

BLEACHING AGENT; HYPOCHLORITE SODIUM;

EID: 33645210314     PISSN: 10273719     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (18)

References (13)
  • 1
    • 3142678624 scopus 로고    scopus 로고
    • Should the 'bleach microscopy method' be recommended for improved case detection of tuberculosis? Literature review and key person analysis
    • Ängeby K A, Hoffner S E, Diwan V K. Should the 'bleach microscopy method' be recommended for improved case detection of tuberculosis? Literature review and key person analysis. Int J Tuberc Lung Dis 2004; 8: 806-815.
    • (2004) Int J Tuberc Lung Dis , vol.8 , pp. 806-815
    • Ängeby, K.A.1    Hoffner, S.E.2    Diwan, V.K.3
  • 2
    • 33645231033 scopus 로고
    • Untersuchungen uber antiformin
    • fasc. 1
    • Uhlenhut et Xylander. Untersuchungen uber antiformin. Arb K Gesund 1909; 32, fasc. 1: 158.
    • (1909) Arb K Gesund , vol.32 , pp. 158
    • Uhlenhut1    Xylander2
  • 3
    • 33645228457 scopus 로고
    • The bacteriological examination of sputum and urine
    • Anonymous. The bacteriological examination of sputum and urine. Lancet 1908; 2: 601.
    • (1908) Lancet , vol.2 , pp. 601
  • 4
    • 0343920261 scopus 로고
    • Concentration of tubercule bacilli from sputum by chemical flocculation methods
    • Hanks J H, Clark H F, Feldman A B. Concentration of tubercule bacilli from sputum by chemical flocculation methods. J Lab Clin Med 1938; 23: 736-746.
    • (1938) J Lab Clin Med , vol.23 , pp. 736-746
    • Hanks, J.H.1    Clark, H.F.2    Feldman, A.B.3
  • 5
    • 33645222204 scopus 로고
    • Ein anreicherungsverfahren für den nachweis von tuberkelbaxillen im sputum
    • Ditthorn F, Schultz W. Ein Anreicherungsverfahren für den Nachweis von Tuberkelbaxillen im Sputum. Centralbl F Bakt 1916-1917; 79: 166.
    • (1916) Centralbl F Bakt , vol.79 , pp. 166
    • Ditthorn, F.1    Schultz, W.2
  • 6
    • 33645225715 scopus 로고
    • An improved technique for the staining of sputum for tubercle bacilli
    • Distaso A. An improved technique for the staining of sputum for tubercle bacilli. Lancet 1920; 81: 19.
    • (1920) Lancet , vol.81 , pp. 19
    • Distaso, A.1
  • 7
    • 33645227206 scopus 로고
    • Ein neues tuberkelbazillenanreicherungsverfahren mit mastixemultion
    • Pfeiffer R, Robitscheck W. Ein neues Tuberkelbazillenanreicherungsverfahren mit Mastixemultion, Cetralbl. F Bakt 1921; 27: 87.
    • (1921) Cetralbl F Bakt , vol.27 , pp. 87
    • Pfeiffer, R.1    Robitscheck, W.2
  • 8
    • 33645231035 scopus 로고
    • Note on a method for the sedimentation of tubercle bacilli
    • Greenfield J G, Anderson J. Note on a method for the sedimentation of tubercle bacilli. Lancet 1919; 2: 423.
    • (1919) Lancet , vol.2 , pp. 423
    • Greenfield, J.G.1    Anderson, J.2
  • 10
    • 0028275722 scopus 로고
    • Evaluation of a safe sputum processing method for detecting tuberculosis
    • Rattan A, Kishore K, Singh S, Jaber M, Xess I, Kumar R. Evaluation of a safe sputum processing method for detecting tuberculosis. J Clin Pathol 1994; 47: 411-413.
    • (1994) J Clin Pathol , vol.47 , pp. 411-413
    • Rattan, A.1    Kishore, K.2    Singh, S.3    Jaber, M.4    Xess, I.5    Kumar, R.6
  • 11
    • 0028905869 scopus 로고
    • Improved microscopical diagnosis of pulmonary tuberculosis in developing countries
    • Gehre N, Karlsson U, Jonsson G, et al. Improved microscopical diagnosis of pulmonary tuberculosis in developing countries. Trans R Soc Trop Med Hyg 1995; 89: 191-193.
    • (1995) Trans R Soc Trop Med Hyg , vol.89 , pp. 191-193
    • Gehre, N.1    Karlsson, U.2    Jonsson, G.3
  • 12
    • 0342264523 scopus 로고    scopus 로고
    • Bleach sedimentation method for increased sensitivity of sputum smear microscopy: Does it work?
    • Van Denn A, Maug A K, Cooreman E, et al. Bleach sedimentation method for increased sensitivity of sputum smear microscopy: does it work? Int J Tuberc Lung Dis 2000; 4: 371-376.
    • (2000) Int J Tuberc Lung Dis , vol.4 , pp. 371-376
    • Van Denn, A.1    Maug, A.K.2    Cooreman, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.