-
3
-
-
0032099044
-
Carrier based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors
-
P. Buhlmann, E. Pretsch, and E. Bakker Carrier based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors Chem. Rev. 98 1998 1593
-
(1998)
Chem. Rev.
, vol.98
, pp. 1593
-
-
Buhlmann, P.1
Pretsch, E.2
Bakker, E.3
-
4
-
-
0002394176
-
The development of polymer matrix membranes for ion-selective electrodes
-
G.J. Moody, B.B. Saad, and J.D.R. Thomas The development of polymer matrix membranes for ion-selective electrodes Sel. Electrode Rev. 10 1988 71
-
(1988)
Sel. Electrode Rev.
, vol.10
, pp. 71
-
-
Moody, G.J.1
Saad, B.B.2
Thomas, J.D.R.3
-
5
-
-
4544366331
-
Carrier based ion-selective electrodes and bulk optodes. 1. General characteristics
-
E. Bakker, P. Buhlmann, and E. Pretsch Carrier based ion-selective electrodes and bulk optodes. 1. General characteristics Chem. Rev. 97 1997 3083
-
(1997)
Chem. Rev.
, vol.97
, pp. 3083
-
-
Bakker, E.1
Buhlmann, P.2
Pretsch, E.3
-
6
-
-
0013401711
-
New coated-wire cobalt(II)-selective electrode based on the benzalthonium tetrathiocyanato cobaltate(II) ion pair
-
K. Burger, and G. Petho New coated-wire cobalt(II)-selective electrode based on the benzalthonium tetrathiocyanato cobaltate(II) ion pair Anal. Chim. Acta 107 1979 113
-
(1979)
Anal. Chim. Acta
, vol.107
, pp. 113
-
-
Burger, K.1
Petho, G.2
-
7
-
-
0004525765
-
Preparation and analytical application of simple coated wire Co (II) and Cr(II) ion-selective electrode
-
Y. Masuda, E. Ishida, K. Hirage, and F. Sekido Preparation and analytical application of simple coated wire Co (II) and Cr(II) ion-selective electrode Nipp. Kag. Kaishi 10 1980 1463
-
(1980)
Nipp. Kag. Kaishi
, vol.10
, pp. 1463
-
-
Masuda, Y.1
Ishida, E.2
Hirage, K.3
Sekido, F.4
-
8
-
-
0019527737
-
A heterogeneous Co(II)-selective electrode and its applications
-
U.S. Lal, M.C. Chattopadhyaya, and A.K. Dey A heterogeneous Co(II)-selective electrode and its applications Electrochim. Acta 26 1981 283
-
(1981)
Electrochim. Acta
, vol.26
, pp. 283
-
-
Lal, U.S.1
Chattopadhyaya, M.C.2
Dey, A.K.3
-
9
-
-
33645158522
-
Cobalt ion-selective electrode with bis(2-ethylhexyl)hydrogen phosphate and chelex-100 resin as sensor
-
S.P. Awasthi, T.C. Thambi, V.T. Kulkarni, and M. Sundaresan Cobalt ion-selective electrode with bis(2-ethylhexyl)hydrogen phosphate and chelex-100 resin as sensor J. Electrochem. Soc. India 40 1991 23
-
(1991)
J. Electrochem. Soc. India
, vol.40
, pp. 23
-
-
Awasthi, S.P.1
Thambi, T.C.2
Kulkarni, V.T.3
Sundaresan, M.4
-
10
-
-
0000544130
-
PVC matrix membrane electrode based on cobalt and nickel phenanthroline complexes for selective determination of Co(II) and Ni(II) ions
-
S.S.M. Hassan, and W.H. Mahmood PVC matrix membrane electrode based on cobalt and nickel phenanthroline complexes for selective determination of Co(II) and Ni(II) ions Mikrochim. Acta 117 1995 121
-
(1995)
Mikrochim. Acta
, vol.117
, pp. 121
-
-
Hassan, S.S.M.1
Mahmood, W.H.2
-
11
-
-
0030980259
-
Macrocycle based membrane sensors for the determination of cobalt(II) ions
-
A.K. Jain, V.K. Gupta, L.P. Singh, and U. Khurana Macrocycle based membrane sensors for the determination of cobalt(II) ions Analyst 122 1997 583
-
(1997)
Analyst
, vol.122
, pp. 583
-
-
Jain, A.K.1
Gupta, V.K.2
Singh, L.P.3
Khurana, U.4
-
12
-
-
0034799737
-
Cobalt(II)-selective membrane electrode based on a recently synthesized benzo-substituted macrocyclic diamide
-
M. Shamsipur, T. Poursaberi, S. Rouhani, K. Niknam, H. Sharghi, and M.R. Ganjali Cobalt(II)-selective membrane electrode based on a recently synthesized benzo-substituted macrocyclic diamide Anal. Sci. 17 2001 1049
-
(2001)
Anal. Sci.
, vol.17
, pp. 1049
-
-
Shamsipur, M.1
Poursaberi, T.2
Rouhani, S.3
Niknam, K.4
Sharghi, H.5
Ganjali, M.R.6
-
13
-
-
0036305205
-
Cobalt(II)-selective coated graphite PVC-membrane electrode based on a recently synthesized dibenzopyridino-substituted macrocyclic diamide
-
M. Shamsipur, S. Rouhani, T. Poursaberi, M.R. Ganjali, H. Sharghi, and K. Niknam Cobalt(II)-selective coated graphite PVC-membrane electrode based on a recently synthesized dibenzopyridino-substituted macrocyclic diamide Electroanalysis 14 2002 729
-
(2002)
Electroanalysis
, vol.14
, pp. 729
-
-
Shamsipur, M.1
Rouhani, S.2
Poursaberi, T.3
Ganjali, M.R.4
Sharghi, H.5
Niknam, K.6
-
14
-
-
0036644360
-
Cobalt(II)-selective membrane using a recently synthesized compound
-
M.H. Mashhadizadeh, A. Momeni, and R. Razavi Cobalt(II)-selective membrane using a recently synthesized compound Anal. Chim. Acta 462 2002 245
-
(2002)
Anal. Chim. Acta
, vol.462
, pp. 245
-
-
Mashhadizadeh, M.H.1
Momeni, A.2
Razavi, R.3
-
15
-
-
1842427554
-
Synthesis of a new oxime and its application to the construction of a highly selective and sensitive Co(II) PVC-based membrane sensor
-
M.R. Ganjali, F. Mizani, M. Emami, M. Darjezini, M.R. Darvich, and M. Yousefi Synthesis of a new oxime and its application to the construction of a highly selective and sensitive Co(II) PVC-based membrane sensor Anal. Sci. 20 2004 531
-
(2004)
Anal. Sci.
, vol.20
, pp. 531
-
-
Ganjali, M.R.1
Mizani, F.2
Emami, M.3
Darjezini, M.4
Darvich, M.R.5
Yousefi, M.6
-
16
-
-
0032942333
-
Chromium(III)-selective electrode based on a macrocyclic compound
-
A.K. Singh, Shailendra, A. Panwar, and S. Baniwal Chromium(III)-selective electrode based on a macrocyclic compound Analyst 124 1999 521
-
(1999)
Analyst
, vol.124
, pp. 521
-
-
Singh, A.K.1
Shailendra2
Panwar, A.3
Baniwal, S.4
-
18
-
-
0010965150
-
Nickel(II)-selective membrane electrode based on macrocyclic ligand
-
A.K. Singh, C.L. Sharma, S. Baniwal, and A. Panwar Nickel(II)-selective membrane electrode based on macrocyclic ligand Electroanalysis 13 2001 1209
-
(2001)
Electroanalysis
, vol.13
, pp. 1209
-
-
Singh, A.K.1
Sharma, C.L.2
Baniwal, S.3
Panwar, A.4
-
19
-
-
2342479854
-
Mercury(II)-selective membrane electrode using tetrathiadiazacyclotetradeca-2,9-diene as neutral carrier
-
A.K. Singh, G. Bhattacharjee, and R. Singh Mercury(II)-selective membrane electrode using tetrathiadiazacyclotetradeca-2,9-diene as neutral carrier Sens. Actuators B 99 2004 36
-
(2004)
Sens. Actuators B
, vol.99
, pp. 36
-
-
Singh, A.K.1
Bhattacharjee, G.2
Singh, R.3
-
21
-
-
77949909718
-
Recommended procedure for calibration of ion-selective electrode
-
R.P. Buck, and V. Cosofret Recommended procedure for calibration of ion-selective electrode Pure Appl. Chem. 65 1993 1849
-
(1993)
Pure Appl. Chem.
, vol.65
, pp. 1849
-
-
Buck, R.P.1
Cosofret, V.2
-
22
-
-
0000123045
-
Nitrate ion-selective sensor based on electrochemically prepared conducting polypyrrole films
-
B.T. Sun, and P.G. Fitch Nitrate ion-selective sensor based on electrochemically prepared conducting polypyrrole films Electroanalysis 9 1997 494
-
(1997)
Electroanalysis
, vol.9
, pp. 494
-
-
Sun, B.T.1
Fitch, P.G.2
-
23
-
-
84876596105
-
Selectivity Coefficients for ion-selective electrode: Recommended methods for reporting values
-
Y. Umezawa, K. Umezawa, and H. Sato Selectivity Coefficients for ion-selective electrode: recommended methods for reporting values Pure Appl. Chem. 67 1995 507
-
(1995)
Pure Appl. Chem.
, vol.67
, pp. 507
-
-
Umezawa, Y.1
Umezawa, K.2
Sato, H.3
|