메뉴 건너뛰기




Volumn 32, Issue 4, 2006, Pages 577-584

Volume-controlled intermittent mandatory ventilation in preterm infants with hypoxemic episodes

Author keywords

Artificial respiration; Hypoxemia; Very low birth weight infant

Indexed keywords

ANALYTICAL PARAMETERS; ARTICLE; BRADYCARDIA; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; CROSSOVER PROCEDURE; FRACTION OF INSPIRED OXYGEN; HUMAN; HYPOXEMIA; INFANT; INFANT DISEASE; INTERMITTENT MANDATORY VENTILATION; NEWBORN; NEWBORN INTENSIVE CARE; OXYGEN SATURATION; OXYGEN TENSION; OXYGENATION; PREMATURITY; PRESSURE CONTROLLED INTERMITTENT MANDATORY VENTILATION; RANDOMIZED CONTROLLED TRIAL; TIDAL VOLUME; UNIVERSITY HOSPITAL; VERY LOW BIRTH WEIGHT; VOLUME CONTROLLED INTERMITTENT MANDATORY VENTILATION;

EID: 33645107040     PISSN: 03424642     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00134-006-0079-8     Document Type: Article
Times cited : (23)

References (20)
  • 1
    • 0026899128 scopus 로고
    • Spontaneous desaturations in intubated very low birth weight infants with acute and chronic lung disease
    • Durand M, McEvoy C, MacDonald K (1992) Spontaneous desaturations in intubated very low birth weight infants with acute and chronic lung disease. Pediatr Pulmonol 13:136-142
    • (1992) Pediatr Pulmonol , vol.13 , pp. 136-142
    • Durand, M.1    McEvoy, C.2    MacDonald, K.3
  • 2
    • 0026731625 scopus 로고
    • Potential role of intrapulmonary shunting in the genesis of hypoxemic episodes in infants an young children
    • Poets CF, Samuels MP, Southall DP (1992) Potential role of intrapulmonary shunting in the genesis of hypoxemic episodes in infants an young children. Pediatrics 90:385-391
    • (1992) Pediatrics , vol.90 , pp. 385-391
    • Poets, C.F.1    Samuels, M.P.2    Southall, D.P.3
  • 4
    • 0034072367 scopus 로고    scopus 로고
    • Pulse oximeters' reliability in detecting hypoxemia and bradycardia: Comparison between a conventional and two new generation oximeters
    • Bohnhorst B, Peter CS, Poets CF (2000) Pulse oximeters' reliability in detecting hypoxemia and bradycardia: Comparison between a conventional and two new generation oximeters. Crit Care Med 28:1565-1568
    • (2000) Crit Care Med , vol.28 , pp. 1565-1568
    • Bohnhorst, B.1    Peter, C.S.2    Poets, C.F.3
  • 6
    • 0028619850 scopus 로고
    • Evaluation of experiments with adaptive interim analyses
    • Bauer B, Koehne K (1994) Evaluation of experiments with adaptive interim analyses. Biometrics 50:1029-1041
    • (1994) Biometrics , vol.50 , pp. 1029-1041
    • Bauer, B.1    Koehne, K.2
  • 9
    • 0036735760 scopus 로고    scopus 로고
    • Relation of sleep state to hypoxemic episodes in ventilated extremely-low-birth-weight infants
    • Lehtonen L, Johnson MW, Bakdash T, Martin RJ, Miller MJ, Scher MS (2002) Relation of sleep state to hypoxemic episodes in ventilated extremely-low-birth- weight infants. J Pediatr 141:363-369
    • (2002) J Pediatr , vol.141 , pp. 363-369
    • Lehtonen, L.1    Johnson, M.W.2    Bakdash, T.3    Martin, R.J.4    Miller, M.J.5    Scher, M.S.6
  • 10
    • 0030827643 scopus 로고    scopus 로고
    • Characteristics of hypoxemic episodes in very low birth weight infants on ventilatory support
    • Dimaguila MA, Di Fiore JM, Martin RJ, Miller MJ (1997) Characteristics of hypoxemic episodes in very low birth weight infants on ventilatory support. J Pediatr 130:577-583
    • (1997) J Pediatr , vol.130 , pp. 577-583
    • Dimaguila, M.A.1    Di Fiore, J.M.2    Martin, R.J.3    Miller, M.J.4
  • 12
    • 0033966401 scopus 로고    scopus 로고
    • Supplemental therapeutic oxygen for prethreshold retinopathy of prematurity (STOP-ROP), a randomized, controlled trial. I. Primary outcomes
    • The STOP-ROP Multicenter Study Group (2000) Supplemental therapeutic oxygen for prethreshold retinopathy of prematurity (STOP-ROP), a randomized, controlled trial. I. Primary outcomes. Pediatrics 105:295-310
    • (2000) Pediatrics , vol.105 , pp. 295-310
  • 14
    • 0027565974 scopus 로고
    • Episodes of spontaneous desaturations in infants with chronic lung disease at two different levels of oxygenation
    • McEvoy C, Durand M, Hewlett V (1993) Episodes of spontaneous desaturations in infants with chronic lung disease at two different levels of oxygenation. Pediatr Pulmonol 15:140-144
    • (1993) Pediatr Pulmonol , vol.15 , pp. 140-144
    • McEvoy, C.1    Durand, M.2    Hewlett, V.3
  • 15
    • 0346850818 scopus 로고    scopus 로고
    • Resolving our uncertainty about oxygen therapy
    • Cole CH, Wright KW, Tarnow-Mordi W, Phelps DL, Pulse Oximetry Saturation Trial for Prevention of Retinopathy of Prematurity Planning Study Group (2003) Resolving our uncertainty about oxygen therapy. Pediatrics 112:1415-1419
    • (2003) Pediatrics , vol.112 , pp. 1415-1419
    • Ch, C.1    Wright, K.W.2    Tarnow-Mordi, W.3    Phelps, D.L.4
  • 16
    • 0036725587 scopus 로고    scopus 로고
    • Effects of volume-guaranteed synchronized intermittent mandatory ventilation in preterm infants recovering from respiratory failure
    • Herrera CM, Gerhardt T, Claure N, Everett R, Musante G, Thomas C, Bancalari E (2002) Effects of volume-guaranteed synchronized intermittent mandatory ventilation in preterm infants recovering from respiratory failure. Pediatrics 110:529-533
    • (2002) Pediatrics , vol.110 , pp. 529-533
    • Herrera, C.M.1    Gerhardt, T.2    Claure, N.3    Everett, R.4    Musante, G.5    Thomas, C.6    Bancalari, E.7
  • 17
    • 23144436685 scopus 로고    scopus 로고
    • Volume guarantee ventilation, interrupted expiration, and expiratory braking
    • McCallion N, Lau R, Dargaville PA, Morley CJ (2005) Volume guarantee ventilation, interrupted expiration, and expiratory braking. Arch Dis Child 90:865-870
    • (2005) Arch Dis Child , vol.90 , pp. 865-870
    • McCallion, N.1    Lau, R.2    Dargaville, P.A.3    Morley, C.J.4
  • 18
    • 0035003847 scopus 로고    scopus 로고
    • Closed-loop controlled inspired oxygen concentration for mechanically ventilated very low birth weight infants with frequent episodes of hypoxemia
    • Claure N, Gerhardt T, Everett R, Musante G, Herrera C, Bancalari E (2001) Closed-loop controlled inspired oxygen concentration for mechanically ventilated very low birth weight infants with frequent episodes of hypoxemia. Pediatrics 107:1120-1124
    • (2001) Pediatrics , vol.107 , pp. 1120-1124
    • Claure, N.1    Gerhardt, T.2    Everett, R.3    Musante, G.4    Herrera, C.5    Bancalari, E.6
  • 19
    • 0031459390 scopus 로고    scopus 로고
    • Computer-controlled minute ventilation in preterm infants undergoing mechanical ventilation
    • Claure N, Gerhardt T, Hummler H, Everett R, Bancalari E (1997) Computer-controlled minute ventilation in preterm infants undergoing mechanical ventilation. J Pediatr 131:910-913
    • (1997) J Pediatr , vol.131 , pp. 910-913
    • Claure, N.1    Gerhardt, T.2    Hummler, H.3    Everett, R.4    Bancalari, E.5
  • 20
    • 0030665943 scopus 로고    scopus 로고
    • Prone positioning decreases episodes of hypoxemia in extremely low birth weight infants (1000 grams or less) with chronic lung disease
    • McEvoy C, Mendoza ME, Bowling S, Hewlett V, Sardesai S, Durand M (1997) Prone positioning decreases episodes of hypoxemia in extremely low birth weight infants (1000 grams or less) with chronic lung disease. J Pediatr 130:305-309
    • (1997) J Pediatr , vol.130 , pp. 305-309
    • McEvoy, C.1    Mendoza, M.E.2    Bowling, S.3    Hewlett, V.4    Sardesai, S.5    Durand, M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.