메뉴 건너뛰기




Volumn 442, Issue , 2006, Pages 35-38

Three-dimensional planning and virtual radiographs in revision total hip arthroplasty for instability

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; ACETABULOPLASTY; AGED; BONE SCREW; CASE REPORT; COMPUTER ASSISTED DIAGNOSIS; CONFERENCE PAPER; FEMALE; FRACTURE FIXATION; HIP RADIOGRAPHY; HUMAN; JOINT STABILITY; PREOPERATIVE PERIOD; PRIORITY JOURNAL; REOPERATION; SURGICAL TECHNIQUE; THREE DIMENSIONAL IMAGING; TOTAL HIP PROSTHESIS; VIRTUAL REALITY; ARTICLE; COMPUTER ASSISTED SURGERY; COMPUTER ASSISTED TOMOGRAPHY; COMPUTER INTERFACE; HIP ARTHROPLASTY; JOINT INSTABILITY; PATIENT CARE PLANNING; RADIOGRAPHY;

EID: 33645076543     PISSN: 0009921X     EISSN: 15281132     Source Type: Journal    
DOI: None     Document Type: Conference Paper
Times cited : (27)

References (15)
  • 1
    • 0031719836 scopus 로고    scopus 로고
    • Primary and revision total hip replacement using the Robodoc system
    • Bargar WL, Bauer A, Borner M. Primary and revision total hip replacement using the Robodoc system. Clin Orthop Relat Res. 1998;354:82-91.
    • (1998) Clin Orthop Relat Res , vol.354 , pp. 82-91
    • Bargar, W.L.1    Bauer, A.2    Borner, M.3
  • 2
    • 0035216823 scopus 로고    scopus 로고
    • Stem design and dislocation after revision total hip arthroplasty: Clinical results and computer modeling
    • Barrack RL, Butler RA, Laster DR, Andrews P. Stem design and dislocation after revision total hip arthroplasty: clinical results and computer modeling. J Arthroplasty. 2001;16(Suppl 1):8-12.
    • (2001) J Arthroplasty , vol.16 , Issue.1 SUPPL. , pp. 8-12
    • Barrack, R.L.1    Butler, R.A.2    Laster, D.R.3    Andrews, P.4
  • 3
    • 27244451801 scopus 로고    scopus 로고
    • Measurements of acetabular cup position and pelvic spatial orientation after total hip arthroplasty using computed tomography/radiography matching
    • Blendea S, Eckman K, Jaramaz B, Levison TJ, DiGioia AM III. Measurements of acetabular cup position and pelvic spatial orientation after total hip arthroplasty using computed tomography/radiography matching. Comput Aided Surg. 2005;10:37-43.
    • (2005) Comput Aided Surg , vol.10 , pp. 37-43
    • Blendea, S.1    Eckman, K.2    Jaramaz, B.3    Levison, T.J.4    DiGioia III, A.M.5
  • 4
    • 0027048727 scopus 로고
    • Operative correction of an unstable total hip arthroplasty
    • Daly PJ, Morrey BF. Operative correction of an unstable total hip arthroplasty. J Bone Joint Surg. 1992;74A:1334-1343.
    • (1992) J Bone Joint Surg , vol.74 A , pp. 1334-1343
    • Daly, P.J.1    Morrey, B.F.2
  • 8
    • 0035215946 scopus 로고    scopus 로고
    • Treatment of the unstable total hip arthroplasty using modularity, soft tissue and allograft reconstruction
    • McGann WA, Welch RB. Treatment of the unstable total hip arthroplasty using modularity, soft tissue and allograft reconstruction. J Arthroplasty. 2001;16(Suppl 1):19-23.
    • (2001) J Arthroplasty , vol.16 , Issue.1 SUPPL. , pp. 19-23
    • McGann, W.A.1    Welch, R.B.2
  • 9
    • 0026766148 scopus 로고
    • Instability after total hip arthroplasty
    • Morrey BF. Instability after total hip arthroplasty. Orthop Clin North Am. 1992;23:237-248.
    • (1992) Orthop Clin North Am , vol.23 , pp. 237-248
    • Morrey, B.F.1
  • 10
    • 0242320921 scopus 로고    scopus 로고
    • Intraoperative 3D reconstruction of the PMMA plug for computer-assisted revision of total hip arthroplasty based on 2D X-ray images Z
    • Ohnsorge JA, de la Fuente M, Jetzki S, Wirtz DC, Radermacher K. Intraoperative 3D reconstruction of the PMMA plug for computer-assisted revision of total hip arthroplasty based on 2D X-ray images Z. Orthop Ihre Grenzgeb. 2003;141:531-539.
    • (2003) Orthop Ihre Grenzgeb , vol.141 , pp. 531-539
    • Ohnsorge, J.A.1    De La Fuente, M.2    Jetzki, S.3    Wirtz, D.C.4    Radermacher, K.5
  • 11
    • 0036083621 scopus 로고    scopus 로고
    • Computer assisted screw insertion into real 3D rapid prototyping pelvis models
    • Peters P, Langlotz F, Nolte LP. Computer assisted screw insertion into real 3D rapid prototyping pelvis models. Clin Biomech (Bristol, Avon). 2002;17:376-382.
    • (2002) Clin Biomech (Bristol, Avon) , vol.17 , pp. 376-382
    • Peters, P.1    Langlotz, F.2    Nolte, L.P.3
  • 13
    • 0035209702 scopus 로고    scopus 로고
    • Epidemiology of instability after total hip replacement
    • Sanchez-Sotelo J, Berry DJ. Epidemiology of instability after total hip replacement. Orthop Clin North Am. 2001;32:543-552.
    • (2001) Orthop Clin North Am , vol.32 , pp. 543-552
    • Sanchez-Sotelo, J.1    Berry, D.J.2
  • 14
    • 0032701727 scopus 로고    scopus 로고
    • Finite element analysis of a novel design approach to resisting total hip dislocation
    • Scifert CF, Brown TD, Lipman JD. Finite element analysis of a novel design approach to resisting total hip dislocation. Clin Biomech. 1999;14:697-703.
    • (1999) Clin Biomech , vol.14 , pp. 697-703
    • Scifert, C.F.1    Brown, T.D.2    Lipman, J.D.3
  • 15
    • 0033182557 scopus 로고    scopus 로고
    • Computer-integrated revision total hip replacement surgery: Concept and preliminary results
    • Taylor RH, Joskowicz L, Williamson B. Computer-integrated revision total hip replacement surgery: Concept and preliminary results. Med Image Anal. 1999;3:301-319.
    • (1999) Med Image Anal , vol.3 , pp. 301-319
    • Taylor, R.H.1    Joskowicz, L.2    Williamson, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.