메뉴 건너뛰기




Volumn , Issue , 2005, Pages 341-349

Development of an integrated electronic nose to reliably measure odors

Author keywords

Ammonia; Concentration; Electronic nose; Hydrogen sulfide; Measurement; Odor

Indexed keywords

AMMONIA; HYDROGEN SULFIDE; MEASUREMENTS; NEURAL NETWORKS; ODORS;

EID: 33645022841     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (3)

References (12)
  • 3
    • 0035545690 scopus 로고    scopus 로고
    • The dangers of creating false classifications due to noise in electronic nose and similar multivariate analyses
    • Goodner, K. L., J. G. Dreher, and R. L. Rouseff, 2001. The dangers of creating false classifications due to noise in electronic nose and similar multivariate analyses. Sensors and Actuators B: Chemical, 80(3), 261-266.
    • (2001) Sensors and Actuators B: Chemical , vol.80 , Issue.3 , pp. 261-266
    • Goodner, K.L.1    Dreher, J.G.2    Rouseff, R.L.3
  • 5
    • 0002439555 scopus 로고    scopus 로고
    • Use of an electronic nose to measure odor concentration following application of cattle slurry to Grassland
    • Misselbrook, T. H., P. J. Hobbs, and K. C. Persaud, 1997. Use of an Electronic Nose to Measure Odor Concentration Following Application of Cattle Slurry to Grassland. Journal of Agricultural Engineering Research, 66(3), 213-220.
    • (1997) Journal of Agricultural Engineering Research , vol.66 , Issue.3 , pp. 213-220
    • Misselbrook, T.H.1    Hobbs, P.J.2    Persaud, K.C.3
  • 7
    • 0035683783 scopus 로고    scopus 로고
    • Development of an eight-panellist single port, forced-choice, dynamic dilution olfactometer
    • Feddes, J. J. R., G. Qu, C. A. Ouellette, and J. J. Leonard, 2001. Development of an eight-panellist single port, forced-choice, dynamic dilution olfactometer. Canadian Biosystems Engineering, 43, 6.1 - 6.5.
    • (2001) Canadian Biosystems Engineering , vol.43
    • Feddes, J.J.R.1    Qu, G.2    Ouellette, C.A.3    Leonard, J.J.4
  • 11
    • 0033080625 scopus 로고    scopus 로고
    • Assessment of odors from sewage treatment works by an electronic nose, H2S analysis and olfactometry
    • Stuetz, R. M., R. A. Fenner, and G. Engin, 1999. Assessment of odors from sewage treatment works by an electronic nose, H2S analysis and olfactometry. Water Research, 33(2), 453-461
    • (1999) Water Research , vol.33 , Issue.2 , pp. 453-461
    • Stuetz, R.M.1    Fenner, R.A.2    Engin, G.3
  • 12
    • 0001743356 scopus 로고    scopus 로고
    • Aggregation of sensory input for robust performance in chemical sensing microsystems
    • Wilson, D. M., T. Roppel, and R. Kalim. (2000). "Aggregation of sensory input for robust performance in chemical sensing microsystems." Sensors and Actuators B: Chemical, 64(13), 107-117.
    • (2000) Sensors and Actuators B: Chemical , vol.64 , Issue.13 , pp. 107-117
    • Wilson, D.M.1    Roppel, T.2    Kalim, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.