메뉴 건너뛰기




Volumn 30, Issue 1, 2006, Pages 16-23

Estimation of mechanical heart valve cavitation in an electro-hydraulic total artificial heart

Author keywords

Cavitation intensity; Electro hydraulic total artificial heart; Filling condition; Mechanical heart valve

Indexed keywords

ARTIFICIAL HEART; CAVITATION; FILLING; PUMPS; VALVES (MECHANICAL);

EID: 33645005240     PISSN: 0160564X     EISSN: 15251594     Source Type: Journal    
DOI: 10.1111/j.1525-1594.2006.00175.x     Document Type: Article
Times cited : (11)

References (20)
  • 2
    • 0028298260 scopus 로고
    • Occluder closing behavior: A key factor in mechanical heart valve cavitation
    • Wu ZJ Wang Y Hwang NHC Occluder closing behavior: a key factor in mechanical heart valve cavitation J Heart Valve Dis 1994 3 Suppl. 1 25 34
    • (1994) J Heart Valve Dis , vol.3 , Issue.1 SUPPL. , pp. 25-34
    • Wu, Z.J.1    Wang, Y.2    Hwang, N.H.C.3
  • 3
    • 0028303198 scopus 로고
    • An experimental-computational analysis of MHV cavitation: Effects of leaflet squeezing and rebound
    • Makhijani VB Yang HQ Singhal AK Hwang NHC An experimental-computational analysis of MHV cavitation: effects of leaflet squeezing and rebound J Heart Valve Dis 1994 3 Suppl. 1 35 48
    • (1994) J Heart Valve Dis , vol.3 , Issue.1 SUPPL. , pp. 35-48
    • Makhijani, V.B.1    Yang, H.Q.2    Singhal, A.K.3    Hwang, N.H.C.4
  • 4
    • 0028216521 scopus 로고
    • Causes and formation of cavitation in mechanical heart valve
    • Graf T Reul H Detlefs C Wilmes R Rau G Causes and formation of cavitation in mechanical heart valve J Heart Valve Dis 1994 3 Suppl. 1 49 64
    • (1994) J Heart Valve Dis , vol.3 , Issue.1 SUPPL. , pp. 49-64
    • Graf, T.1    Reul, H.2    Detlefs, C.3    Wilmes, R.4    Rau, G.5
  • 5
    • 0034793868 scopus 로고    scopus 로고
    • Mechanisms of mechanical heart valve cavitation: Investigation using a tilting disk valve model
    • He Z Xi B Zhu K Hwang NHC Mechanisms of mechanical heart valve cavitation: investigation using a tilting disk valve model J Heart Valve Dis 2001 10 666 74
    • (2001) J Heart Valve Dis , vol.10 , pp. 666-674
    • He, Z.1    Xi, B.2    Zhu, K.3    Hwang, N.H.C.4
  • 6
    • 0042125061 scopus 로고    scopus 로고
    • Cavitation phenomena in mechanical heart valve: The role of squeeze flow velocity and contact area on cavitation initiation between two impinging rods
    • Lim WL Chew YT Low HT Foo WL Cavitation phenomena in mechanical heart valve: the role of squeeze flow velocity and contact area on cavitation initiation between two impinging rods J Biomech 2003 36 1269 80
    • (2003) J Biomech , vol.36 , pp. 1269-1280
    • Lim, W.L.1    Chew, Y.T.2    Low, H.T.3    Foo, W.L.4
  • 8
    • 0030250463 scopus 로고    scopus 로고
    • Transient pressure signals in mechanical heart valve cavitation
    • Wu ZJ Slonin JH Hwang NHC Transient pressure signals in mechanical heart valve cavitation ASAIO J 1996 42 M555 61
    • (1996) ASAIO J , vol.42 , pp. 555-561
    • Wu, Z.J.1    Slonin, J.H.2    Hwang, N.H.C.3
  • 9
    • 0033892734 scopus 로고    scopus 로고
    • Origin and appearance of HITS induced by prosthetic heart valves: An in vitro study
    • Potthast K Erdönmez G Schnelke C et al. Origin and appearance of HITS induced by prosthetic heart valves: an in vitro study Int J Artif Organs 2000 23 441 5
    • (2000) Int J Artif Organs , vol.23 , pp. 441-445
    • Potthast, K.1    Erdönmez, G.2    Schnelke, C.3
  • 11
  • 12
    • 0033200905 scopus 로고    scopus 로고
    • In vivo demonstration of cavitation potential of a mechanical heart valve
    • Dexter EU Aluri S Radcliffe RR et al. In vivo demonstration of cavitation potential of a mechanical heart valve ASAIO J 1999 45 436 41
    • (1999) ASAIO J , vol.45 , pp. 436-441
    • Dexter, E.U.1    Aluri, S.2    Et Al., R.R.R.3
  • 13
    • 0027943765 scopus 로고
    • Cavitation dynamics of mechanical heart valve prostheses
    • Lee CS Chandran KB Chen LD Cavitation dynamics of mechanical heart valve prostheses Artif Organs 1994 18 758 67
    • (1994) Artif Organs , vol.18 , pp. 758-767
    • Lee, C.S.1    Chandran, K.B.2    Chen, L.D.3
  • 15
    • 0029099224 scopus 로고
    • An interlaboratory comparison of the FDA protocol for the evaluation of cavitation potential of mechanical heart valves
    • Carey RF Porter JM Richard G et al. An interlaboratory comparison of the FDA protocol for the evaluation of cavitation potential of mechanical heart valves J Heart Valve Dis 1995 4 532 41
    • (1995) J Heart Valve Dis , vol.4 , pp. 532-541
    • Carey, R.F.1    Porter, J.M.2    Et Al., R.G.3
  • 16
    • 18744388099 scopus 로고    scopus 로고
    • Mechanism for cavitation in the mechanical heart valve with an artificial heart: Nuclei and viscosity dependence
    • Lee HS Taenaka Y Kitamura S Mechanism for cavitation in the mechanical heart valve with an artificial heart: nuclei and viscosity dependence Artif Organs 2005 29 41 6
    • (2005) Artif Organs , vol.29 , pp. 41-46
    • Lee, H.S.1    Taenaka, Y.2    Kitamura, S.3
  • 17
    • 0033491106 scopus 로고    scopus 로고
    • Wear patterns from fatigue life testing of a prosthetic heart valve
    • Grigioni M Daniele C D'Avenio G Calcagnini G Barbaro V Wear patterns from fatigue life testing of a prosthetic heart valve Wear 1999 225-229 749 57
    • (1999) Wear , vol.225-229 , pp. 749-757
    • Grigioni, M.1    Daniele, C.2    D'Avenio, G.3    Calcagnini, G.4    Barbaro, V.5
  • 18
    • 0026484064 scopus 로고
    • Review of the global experience with the Medtronic Hall valve
    • Akins CW Review of the global experience with the Medtronic Hall valve Eur J Cardiothorac Surg 1992 6 Suppl. 1 68 74
    • (1992) Eur J Cardiothorac Surg , vol.6 , Issue.1 SUPPL. , pp. 68-74
    • Akins, C.W.1
  • 20
    • 0038556975 scopus 로고    scopus 로고
    • The national cardiovascular center electrohydraulic total artificial heart and ventricular assist device systems: Current status of development
    • Tatsumi E Taenaka Y Homma A et al. The national cardiovascular center electrohydraulic total artificial heart and ventricular assist device systems: current status of development ASAIO J 2003 49 243 9
    • (2003) ASAIO J , vol.49 , pp. 243-249
    • Tatsumi, E.1    Taenaka, Y.2    Homma, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.