-
1
-
-
0026742012
-
Ytterbium-169: Calculated physical properties of a new radiation source for brachytherapy
-
D. L. D. Mason, J. J. Battista, R. B. Barnett, and A. T. Porter, " Ytterbium-169: Calculated physical properties of a new radiation source for brachytherapy, " Med. Phys. 19, 695-703 (1992).
-
(1992)
Med. Phys.
, vol.19
, pp. 695-703
-
-
Mason, D.L.D.1
-
2
-
-
0028891525
-
Dose distributions and dose rate constants for new ytterbium-169 brachytherapy seeds
-
M. S. MacPherson and J. J. Battista, " Dose distributions and dose rate constants for new ytterbium-169 brachytherapy seeds, " Med. Phys. 22, 89-96 (1995).
-
(1995)
Med. Phys.
, vol.22
, pp. 89-96
-
-
MacPherson, M.S.1
-
3
-
-
0028990721
-
169Yb seed model X1267
-
169Yb seed model X1267, " Phys. Med. Biol. 40, 1317-1330 (1995).
-
(1995)
Phys. Med. Biol.
, vol.40
, pp. 1317-1330
-
-
Piermattei., A.1
-
4
-
-
0028274912
-
Dosimetric characteristics, air-kerma strength calibration and verification of Monte Carlo simulation for a new ytterbium-169 brachytherapy source
-
H. Perera, J. F. Williamson, Z. Li, V. Mishra, and A. S. Meigooni, " Dosimetric characteristics, air-kerma strength calibration and verification of Monte Carlo simulation for a new ytterbium-169 brachytherapy source, " Int. J. Radiat. Oncol., Biol., Phys. 28, 953-970 (1994).
-
(1994)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.28
, pp. 953-970
-
-
Perera, H.1
-
5
-
-
0029021433
-
A secondary air kerma strength standard for Yb-169 interstitial brachytherapy sources
-
P. K. Das, V. Mishra, H. Perera, A. S. Meigooni, and J. F. Williamson, " A secondary air kerma strength standard for Yb-169 interstitial brachytherapy sources, " Phys. Med. Biol. 40, 741-756 (1995).
-
(1995)
Phys. Med. Biol.
, vol.40
, pp. 741-756
-
-
Das, P.K.1
-
6
-
-
0008034975
-
First clinical application of a new brachytherapy source - Ytterbium-169
-
B. Fisher, A. Porter, R. Barnett, D. Mason, E. Papiez, and J. Battista, " First clinical application of a new brachytherapy source - Ytterbium-169, " Endocur. Hypertherm. Oncol. 9, 195-199 (1993).
-
(1993)
Endocur. Hypertherm. Oncol.
, vol.9
, pp. 195-199
-
-
Fisher, B.1
-
7
-
-
0026517467
-
The potential of ytterbium 169 in brachytherapy: A brief physical and radiobiological assessment
-
S. M. Loft, I. P. Coles, and R. G. Dale, " The potential of ytterbium 169 in brachytherapy: a brief physical and radiobiological assessment, " Br. J. Radiol. 65, 252-257 (1992).
-
(1992)
Br. J. Radiol.
, vol.65
, pp. 252-257
-
-
Loft, S.M.1
-
9
-
-
20444431149
-
169Yb and comparison with its reactor-based generation
-
169Yb and comparison with its reactor-based generation, " Int. J. Appl. Radiat. Isot. 63, 235-239 (2005).
-
(2005)
Int. J. Appl. Radiat. Isot.
, vol.63
, pp. 235-239
-
-
Spahn, I.1
-
10
-
-
0035700759
-
Ytterbium-169: A promising new radionuclide for intravascular brachytherapy
-
N. S. Patel, P. Fan, S. T. Chiu-Tsao, K. Ravi, W. Sherman, H. Quon, J. Pisch, H. S. Tsao, and L. B. Harrison, " Ytterbium-169: A promising new radionuclide for intravascular brachytherapy, " Cardiovasc. Radiat. Med. 2, 173-180 (2001).
-
(2001)
Cardiovasc. Radiat. Med.
, vol.2
, pp. 173-180
-
-
Patel, N.S.1
-
11
-
-
14744282491
-
GEC/ESTRO-EAU recommendations on temporary brachytherapy using stepping sources for localised prostate cancer
-
G. Kovács, R. Pötter, T. Loch, J. Hammer, I. K. Kolkman-Deurloo, J. J. M. C. H. de la Rosette, H. Bertermann, " GEC/ESTRO-EAU recommendations on temporary brachytherapy using stepping sources for localised prostate cancer, " Radiother. Oncol. 74, 137-148 (2005).
-
(2005)
Radiother. Oncol.
, vol.74
, pp. 137-148
-
-
Kovács, G.1
-
12
-
-
16344388273
-
High-Dose-Rate Intensity-Modulated Brachytherapy with external beam radiotherapy for prostate cancer: California endocurietherapy's 10-year results
-
D. J. Demanes, R. R. Rodriguez, L. Schour, D. Brandt, and G. Altieri, " High-Dose-Rate Intensity-Modulated Brachytherapy with external beam radiotherapy for prostate cancer: California endocurietherapy's 10-year results, " Int. J. Radiat. Oncol., Biol., Phys. 61, 1306-1316 (2005).
-
(2005)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.61
, pp. 1306-1316
-
-
Demanes, D.J.1
-
13
-
-
12144291223
-
Long-term outcome by risk factors using conformal high-dose-rate brachytherapy (HDR-BT) boost with or without neoadjuvant androgen suppression for localized prostate cancer
-
R. M. Galalae et al., " Long-term outcome by risk factors using conformal high-dose-rate brachytherapy (HDR-BT) boost with or without neoadjuvant androgen suppression for localized prostate cancer, " Int. J. Radiat. Oncol., Biol., Phys. 58, 1048-1055 (2004).
-
(2004)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.58
, pp. 1048-1055
-
-
Galalae, R.M.1
-
14
-
-
0242523827
-
No apparent benefit at 5 years from a course of neoadjuvant/concurrent androgen deprivation for patients with prostate cancer treated with a high total radiation dose
-
A. Martinez, R. Galalae, G. J. Razvan, C. Mitchell, G. Gustafson, and G. Kovacs, " No apparent benefit at 5 years from a course of neoadjuvant/concurrent androgen deprivation for patients with prostate cancer treated with a high total radiation dose, " J. Urol. (Paris), 170, 2296-2301 (2003).
-
(2003)
J. Urol. (Paris)
, vol.170
, pp. 2296-2301
-
-
Martinez, A.1
-
15
-
-
0037295445
-
Results of high dose rate afterloading brachytherapy boost to conventional external beam radiation therapy for initial and locally advanced prostate cancer
-
A. C. A. Pellizzon, W. Nadalin, J. V. Salvajoli, R. C. Fogaroli, P. E. Novaes, M. A. C. Maia, and R. Ferrigno, " Results of high dose rate afterloading brachytherapy boost to conventional external beam radiation therapy for initial and locally advanced prostate cancer, " Radiother. Oncol. 66, 167-172 (2003).
-
(2003)
Radiother. Oncol.
, vol.66
, pp. 167-172
-
-
Pellizzon, A.C.A.1
-
16
-
-
11144354809
-
3D conformal HDR brachytherapy and external beam irradiation combined with temporary androgen deprivation in the treatment of localized prostate cancer
-
T. Martin, S. Roeddiger, R. Kureka, T. Dannenberg, O. Eckart, C. Kolotas, R. Heyd, B. Rogge, D. Baltas, U. Tunn, and N. Zamboglou, " 3D conformal HDR brachytherapy and external beam irradiation combined with temporary androgen deprivation in the treatment of localized prostate cancer, " Radiother. Oncol. 71, 35-41 (2004).
-
(2004)
Radiother. Oncol.
, vol.71
, pp. 35-41
-
-
Martin, T.1
-
17
-
-
0032863710
-
New interstitial HDR brachytherapy technique for prostate cancer: CT based 3D planning after transrectal implantation
-
T. Martin, C. Kolotas, T. Dannenberg, G. Strassmann, H. G. Vogt, R. Heyd, B. Rogge, D. Baltas, R. Kurek, U. Tunn, and N. Zamboglou, " New interstitial HDR brachytherapy technique for prostate cancer: CT based 3D planning after transrectal implantation, " Radiother. Oncol. 52, 257-260 (1999).
-
(1999)
Radiother. Oncol.
, vol.52
, pp. 257-260
-
-
Martin, T.1
-
18
-
-
11144355489
-
3-D conformal HDR brachytherapy as monotherapy for localized prostate cancer. a pilot study
-
T. Martin, D. Baltas, R. Kurek, S. Röddiger, M. Kontova, G. Anagnostopoulos, T. Dannenberg, T. Buhleier, and G. Skazikis, " 3-D conformal HDR brachytherapy as monotherapy for localized prostate cancer. A pilot study, " Strahlenther. Onkol. 180, 225-232 (2004).
-
(2004)
Strahlenther. Onkol.
, vol.180
, pp. 225-232
-
-
Martin, T.1
-
19
-
-
0345269963
-
High-Dose-Rate Brachytherapy as monotherapy for localized prostate cancer: A retrospective analysis with special focus on tolerance and chronic toxicity
-
Y. Yoshioka, T. Nose, K. Yoshida, R.-J. OH, Y. Yamada, E. Tanaka, H. Yamazaki, T. Inoue, and T. Inoue, " High-Dose-Rate Brachytherapy as monotherapy for localized prostate cancer: a retrospective analysis with special focus on tolerance and chronic toxicity, " Int. J. Radiat. Oncol., Biol., Phys. 56, 213-220 (2003).
-
(2003)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.56
, pp. 213-220
-
-
Yoshioka, Y.1
-
20
-
-
21344443791
-
HDR monotherapy for early stage prostate cancer: Toxicity results utilizing the Common Toxicity Criteria
-
G. Gustafson, D. Demanes, R. Rodriguez, C. Mitchell, R. Ravanera, G. Edmundson and A. Martinez, " HDR monotherapy for early stage prostate cancer: Toxicity results utilizing the Common Toxicity Criteria, " Int. J. Radiat. Oncol., Biol., Phys. 57, Suppl, Ab. 176, 230-231 (2003).
-
(2003)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.57
, pp. 230-231
-
-
Gustafson, G.1
-
22
-
-
0035160344
-
Phase II prospective study of the use of conformal high-dose-rate brachytherapy as monotherapy for the treatment of favourable stage prostate cancer: A feasibility report
-
A. A. Martinez, I. Pataki, G. Edmundson, E. Sebastian, D. Brabbins, and G. Gustafson, " Phase II prospective study of the use of conformal high-dose-rate brachytherapy as monotherapy for the treatment of favourable stage prostate cancer: a feasibility report, " Int. J. Radiat. Oncol., Biol., Phys. 49, 61-69 (2001).
-
(2001)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.49
, pp. 61-69
-
-
Martinez, A.A.1
-
23
-
-
0031739032
-
Monte Carlo-aided dosimetry of a new high dose-rate brachytherapy source
-
G. M. Daskalov, E. Loeffler, and J. F. Williamson, " Monte Carlo-aided dosimetry of a new high dose-rate brachytherapy source, " Med. Phys. 25, 2200-2208 (1998).
-
(1998)
Med. Phys.
, vol.25
, pp. 2200-2208
-
-
Daskalov, G.M.1
-
24
-
-
0032518595
-
A conformal Index (COIN) to evaluate implant quality and dose specification in brachytherapy
-
D. Baltas, C. Kolotas, K. Geramani, R. Mould, G. Ioannidis, M. Kekchidi, and N. Zamboglou, " A conformal Index (COIN) to evaluate implant quality and dose specification in brachytherapy, " Int. J. Radiat. Oncol., Biol., Phys., 40, 515-524 (1988).
-
(1988)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.40
, pp. 515-524
-
-
Baltas, D.1
-
25
-
-
0037036521
-
Multiobjective anatomy-based dose optimization for HDR-brachytherapy with constraint free deterministic algorithms
-
N. Milickovic, M. Lahanas, M. Papagiannopoulou, N. Zamboglou and D. Baltas, " Multiobjective anatomy-based dose optimization for HDR-brachytherapy with constraint free deterministic algorithms, " Phys. Med. Biol. 47, 2263-80 (2002).
-
(2002)
Phys. Med. Biol.
, vol.47
, pp. 2263-2280
-
-
Milickovic, N.1
-
26
-
-
85092679691
-
-
Los Alamos, NM: Los Alamos National Laboratory
-
TM - A General Monte Carlo N -Particle Transport Code: Version 4C, " Report LA-13709-M, Los Alamos, NM: Los Alamos National Laboratory, 2000.
-
(2000)
TM* - A General Monte CarloLA-13709-M
-
-
-
28
-
-
0028919251
-
Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group 43
-
R. Nath, L. L. Anderson, G. Luxton, K. A. Weaver, J. F. Williamson, and A. S. Meigooni, " Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group 43, " Med. Phys. 22, 209-234 (1995).
-
(1995)
Med. Phys.
, vol.22
, pp. 209-234
-
-
Nath, R.1
-
29
-
-
1142304255
-
Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations
-
M. J. Rivard, B. M. Coursey, L. A. DeWerd, W. F. Hanson, M. S. Huq, G. S. Ibbott, M. G. Mitch, R. Nath, and J. F. Williamson, " Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations, " Med. Phys. 31, 633-674 (2004).
-
(2004)
Med. Phys.
, vol.31
, pp. 633-674
-
-
Rivard, M.J.1
-
30
-
-
0033679867
-
Monte Carlo dosimetry of a new 192Ir high dose rate brachytherapy source
-
A. Angelopoulos, P. Baras, L. Sakelliou, P. Karaiskos, and P. Sandilos, " Monte Carlo dosimetry of a new 192Ir high dose rate brachytherapy source, " Med. Phys. 27, 2521-2527 (2000).
-
(2000)
Med. Phys.
, vol.27
, pp. 2521-2527
-
-
Angelopoulos, A.1
-
31
-
-
0037423586
-
A hybrid evolutionary multiobjective algorithm for anatomy based dose optimization algorithm in HDR brachytherapy
-
M. Lahanas, D. Baltas, and N. Zamboglou, " A hybrid evolutionary multiobjective algorithm for anatomy based dose optimization algorithm in HDR brachytherapy, " Phys. Med. Biol. 48, 399-415 (2003).
-
(2003)
Phys. Med. Biol.
, vol.48
, pp. 399-415
-
-
Lahanas, M.1
-
32
-
-
0037423928
-
Global convergence analysis of fast multiobjective gradient based dose optimization algorithms for high dose rate brachytherapy
-
M. Lahanas, D. Baltas, S. Giannouli, and N. Zamboglou, " Global convergence analysis of fast multiobjective gradient based dose optimization algorithms for high dose rate brachytherapy, " Phys. Med. Biol. 48, 599-617 (2003).
-
(2003)
Phys. Med. Biol.
, vol.48
, pp. 599-617
-
-
Lahanas, M.1
-
33
-
-
84931475717
-
Comparison of evolutionary and deterministic multiobjective algorithms for dose optimization in brachytherapy
-
Zurich, Switzerland, Lecture Notes in Computer Science, edited by, E. Zitzler, K. Deb, L. Thiele, C. Coello Coello, and, D. Corne, (Springer-Verlag, Berlin
-
N. Milickovic, M. Lahanas, D. Baltas, and N. Zamboglou, " Comparison of evolutionary and deterministic multiobjective algorithms for dose optimization in brachytherapy, " in Proceedings of the 1st International Conference, EMO 2001, Zurich, Switzerland, Lecture Notes in Computer Science, edited by, E. Zitzler, K. Deb, L. Thiele, C. Coello Coello, and, D. Corne, (Springer-Verlag, Berlin, 2001, Vol. 1993, pp. 167-180.
-
(2001)
Proceedings of the 1st International Conference, EMO 2001
, vol.1993
, pp. 167-180
-
-
Milickovic, N.1
Lahanas, M.2
Baltas, D.3
Zamboglou, N.4
-
34
-
-
0032866106
-
Anatomy-based three dimensional dose optimization in brachytherapy using multiobjective genetic algorithms
-
M. Lahanas, D. Baltas, and N. Zamboglou, " Anatomy-based three dimensional dose optimization in brachytherapy using multiobjective genetic algorithms, " Med. Phys. 26, 1904-1918 (1999).
-
(1999)
Med. Phys.
, vol.26
, pp. 1904-1918
-
-
Lahanas, M.1
-
35
-
-
0032692696
-
192Ir sources
-
192Ir sources, " Med. Phys. 26, 2441-2444 (1999).
-
(1999)
Med. Phys.
, vol.26
, pp. 2441-2444
-
-
Borg, J.1
-
36
-
-
0022969959
-
A "natural" volume-dose histogram for brachytherapy
-
L. L. Anderson, " A "natural" volume-dose histogram for brachytherapy, " Med. Phys. 13 898-903 (1986).
-
(1986)
Med. Phys.
, vol.13
, pp. 898-903
-
-
Anderson1
-
37
-
-
0344382541
-
Dose specification and quantification of implant quality
-
edited by, J. F. Williamson, B. R. Thomadsen, and, R. Nath, (American Medical Physics, Madison, WI)
-
L.L. Anderson, " Dose specification and quantification of implant quality, " in Brachytherapy Physics edited by, J. F. Williamson, B. R. Thomadsen, and, R. Nath, (American Medical Physics, Madison, WI, 1995) pp. 343-360.
-
(1995)
Brachytherapy Physics
, pp. 343-360
-
-
Anderson, L.L.1
|