Volumn 32, Issue 12, 2005, Pages 3628-3635

Calculation and validation of the use of effective attenuation coefficient for attenuation correction in In-111 SPECT

Author keywords

111In; Attenuation correction; Collimator blurring; Dual modality imaging; Scatter correction; SPECT; SPECT CT

Indexed keywords

ITERATIVE METHODS; MAXIMUM LIKELIHOOD; NUCLEAR MEDICINE; PARTICLE BEAMS; PHOTONS; RADIOISOTOPES;

EID: 33644994924     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.2128084     Document Type: Article
Times cited : (33)

References (11)
  • 1
    • 0026137030 scopus 로고
    • Quantitative SPECT imaging with indium-111
    • D. R. Gilland, R. J. Jaszczak, T. G. Turkington, K. L. Greer, and R. E. Coleman, " Quantitative SPECT imaging with indium-111, " IEEE Trans. Nucl. Sci. 38, 761-766 (1991).
    • (1991) IEEE Trans. Nucl. Sci. , vol.38 , pp. 761-766
    • Gilland, D.R.1
  • 2
    • 0029902075 scopus 로고    scopus 로고
    • Scatter and attenuation correction for 111In based on energy spectrum fitting
    • M. S. Kaplan et al., " Scatter and attenuation correction for 111In based on energy spectrum fitting, " Med. Phys. 23, 1277-1285 (1996).
    • (1996) Med. Phys. , vol.23 , pp. 1277-1285
    • Kaplan, M.S.1
  • 3
    • 33645452666 scopus 로고    scopus 로고
    • Practical multi-peak attenuation correction with CT data
    • M. Wilk, I. Yuzefovich, R. Carmi, and Y. Shrem, " Practical multi-peak attenuation correction with CT data, " J. Nucl. Med. 43 (suppl 5), 221 (2002).
    • (2002) J. Nucl. Med. , vol.43 , pp. 221
    • Wilk, M.1
  • 6
    • 0037811001 scopus 로고    scopus 로고
    • X-ray-based attenuation correction for positron emission tomography/computed tomography scanners
    • P. E. Kinahan, B. H. Hasegawa, and T. Beyer, " X-ray-based attenuation correction for positron emission tomography/computed tomography scanners, " Semin Nucl. Med. 33, 166-179 (2003).
    • (2003) Semin Nucl. Med. , vol.33 , pp. 166-179
    • Kinahan, P.E.1
  • 8
    • 20644469053 scopus 로고    scopus 로고
    • Correction of photon attenuation and collimator response for a body-contouring SPECT/CT imaging system
    • Y. Seo et al., " Correction of photon attenuation and collimator response for a body-contouring SPECT/CT imaging system, " J. Nucl. Med. 46, 868-877 (2005).
    • (2005) J. Nucl. Med. , vol.46 , pp. 868-877
    • Seo, Y.1
  • 11
    • 0034043247 scopus 로고    scopus 로고
    • Gamma camera-mounted anatomical x-ray tomography: Technology, system characteristics and first images
    • M. Bocher et al., " Gamma camera-mounted anatomical x-ray tomography: Technology, system characteristics and first images, " Eur. J. Nucl. Med. 27, 619-627 (2000).
    • (2000) Eur. J. Nucl. Med. , vol.27 , pp. 619-627
    • Bocher, M.1