-
2
-
-
0032520169
-
Treatment of refractory familial hypercholesterolemia by low-density lipoprotein apheresis using an automated dextran sulfate cellulose adsorption system
-
Gordon BR Kelsey SF Dau PC et al. Treatment of refractory familial hypercholesterolemia by low-density lipoprotein apheresis using an automated dextran sulfate cellulose adsorption system Am J Cardiol 1998 81 407 11
-
(1998)
Am J Cardiol
, vol.81
, pp. 407-11
-
-
Gordon, B.R.1
Kelsey, S.F.2
Dau, P.C.3
-
3
-
-
0032535310
-
Long-term efficacy of low-density lipoprotein apheresis on coronary heart disease in familial hypercholesterolemia
-
on behalf of Hokuriku-FH-LDL-Apheresis Study Group.
-
Mabuchi H Koizumi J Shimizu M et al. on behalf of Hokuriku-FH-LDL- Apheresis Study Group. Long-term efficacy of low-density lipoprotein apheresis on coronary heart disease in familial hypercholesterolemia Am J Cardiol 1998 82 1489 95
-
(1998)
Am J Cardiol
, vol.82
, pp. 1489-95
-
-
Mabuchi, H.1
Koizumi, J.2
Shimizu, M.3
-
4
-
-
0033013792
-
Effects of intensive lowering by low-density lipoprotein apheresis on regression of coronary atherosclerosis in patients with familial hypercholesterolemia: Japan Low-density Lipoprotein Apheresis Coronary Atherosclerosis Prospective Study (L-CAPS)
-
Nishimura S Sekiguchi M Kano T et al. Effects of intensive lowering by low-density lipoprotein apheresis on regression of coronary atherosclerosis in patients with familial hypercholesterolemia: Japan Low-density Lipoprotein Apheresis Coronary Atherosclerosis Prospective Study (L-CAPS) Atherosclerosis 1999 144 409 17
-
(1999)
Atherosclerosis
, vol.144
, pp. 409-17
-
-
Nishimura, S.1
Sekiguchi, M.2
Kano, T.3
-
5
-
-
0029882936
-
Effect of aggressive versus conventional lipid lowering treatment on coronary atherosclerosis
-
on behalf of the LDL-apheresis atherosclerosis regression study (LAARS).
-
Kroon AA Aengevaeren WR van der Werf T et al. on behalf of the LDL-apheresis atherosclerosis regression study (LAARS). Effect of aggressive versus conventional lipid lowering treatment on coronary atherosclerosis Circulation 1996 93 1826 35
-
(1996)
Circulation
, vol.93
, pp. 1826-35
-
-
Kroon, A.A.1
Aengevaeren, W.R.2
Van Der Werf, T.3
-
6
-
-
0041815982
-
Low-density lipoprotein apheresis in the prevention of recurrent coronary heart disease: A review
-
Tasaki H Low-density lipoprotein apheresis in the prevention of recurrent coronary heart disease: a review Ther Apher Dial 2003 7 408 12
-
(2003)
Ther Apher Dial
, vol.7
, pp. 408-12
-
-
Tasaki, H.1
-
7
-
-
0032457845
-
DALI-the first human whole-blood low-density lipoprotein and lipoprotein (a) apheresis system in clinical use: Procedure and clinical results
-
Drager LJ Julius U Kraenzle K et al. DALI-the first human whole-blood low-density lipoprotein and lipoprotein (a) apheresis system in clinical use: procedure and clinical results Eur J Clin Invest 1998 28 944 1002
-
(1998)
Eur J Clin Invest
, vol.28
, pp. 944-1002
-
-
Drager, L.J.1
Julius, U.2
Kraenzle, K.3
-
8
-
-
0032782555
-
Low density lipoprotein hemoperfusion by direct adsorption of lipoproteins from whole blood (DALI apheresis): Clinical experience from a single center
-
Bosch T Lennertz A Kordes B Samtleben W Low density lipoprotein hemoperfusion by direct adsorption of lipoproteins from whole blood (DALI apheresis): clinical experience from a single center Ther Apher 1999 3 209 13
-
(1999)
Ther Apher
, vol.3
, pp. 209-13
-
-
Bosch, T.1
Lennertz, A.2
Kordes, B.3
Samtleben, W.4
-
9
-
-
0034723431
-
Direct adsorption of lipoproteins (DALI) from whole blood: First long-term clinical experience with a new LDL-apheresis system for the treatment of familial hypercholesterolemia
-
Jansen M Banyai S Schmaldienst S et al. Direct adsorption of lipoproteins (DALI) from whole blood: first long-term clinical experience with a new LDL-apheresis system for the treatment of familial hypercholesterolemia Wien Klin Wochenschr 2000 112 61 9
-
(2000)
Wien Klin Wochenschr
, vol.112
, pp. 61-9
-
-
Jansen, M.1
Banyai, S.2
Schmaldienst, S.3
-
10
-
-
0042271714
-
Efficacy and safety of a new whole-blood low-density lipoprotein apheresis system (Liposorber D) in severe hypoercholesterolemia
-
Otto C Kern P Bambauer R Kallert S Schwandt P Parhofer KG Efficacy and safety of a new whole-blood low-density lipoprotein apheresis system (Liposorber D) in severe hypoercholesterolemia Artif Organs 2003 27 1116 22
-
(2003)
Artif Organs
, vol.27
, pp. 1116-22
-
-
Otto, C.1
Kern, P.2
Bambauer, R.3
Kallert, S.4
Schwandt, P.5
Parhofer, K.G.6
-
12
-
-
0036799478
-
In vitro evaluation of dextran sulfate cellulose beads for whole blood infusion low-density lipoprotein-hemoperfusion
-
Kobayashi A Nakatani M Furuyoshi S Tani N In vitro evaluation of dextran sulfate cellulose beads for whole blood infusion low-density lipoprotein-hemoperfusion Ther Apher 2002 6 365 71
-
(2002)
Ther Apher
, vol.6
, pp. 365-71
-
-
Kobayashi, A.1
Nakatani, M.2
Furuyoshi, S.3
Tani, N.4
-
13
-
-
0024393820
-
Comparison of serum of lipid values in variant angina pectoris and fixed coronary artery disease with normal subjects
-
Tasaki H Nakashima Y Nandate H Yashiro A Kawashima T Kuroiwa A Comparison of serum of lipid values in variant angina pectoris and fixed coronary artery disease with normal subjects Am J Cardiol 1989 63 1441 5
-
(1989)
Am J Cardiol
, vol.63
, pp. 1441-5
-
-
Tasaki, H.1
Nakashima, Y.2
Nandate, H.3
Yashiro, A.4
Kawashima, T.5
Kuroiwa, A.6
-
15
-
-
0042608343
-
[ion-selective electrode method.]
-
(in Japanese.)
-
Sekiguchi M [Ion-selective electrode method.] Kensa To Gijutsu 1989 17 1167 72 (in Japanese.)
-
(1989)
Kensa to Gijutsu
, vol.17
, pp. 1167-72
-
-
Sekiguchi, M.1
-
16
-
-
0013977212
-
Determination of citrate with citrate lyase
-
Moellering H Gruber W Determination of citrate with citrate lyase Anal Biochem 1966 17 369 76
-
(1966)
Anal Biochem
, vol.17
, pp. 369-76
-
-
Moellering, H.1
Gruber, W.2
-
17
-
-
0023205747
-
A new low density lipoprotein apheresis system using two dextran sulfate cellulose columns in an automated column regenerating unit (LDL continuous apheresis)
-
Mabuchi H Michishita I Takeda M et al. A new low density lipoprotein apheresis system using two dextran sulfate cellulose columns in an automated column regenerating unit (LDL continuous apheresis) Atherosclerosis 1987 68 19 25
-
(1987)
Atherosclerosis
, vol.68
, pp. 19-25
-
-
Mabuchi, H.1
Michishita, I.2
Takeda, M.3
-
18
-
-
0033868129
-
Prospective randomized cross-over comparison of three LDL-apheresis systems in statin pretreated patients with familial hypercholesterolemia
-
Schmaldienst S Banyai S Stulnig TM et al. Prospective randomized cross-over comparison of three LDL-apheresis systems in statin pretreated patients with familial hypercholesterolemia Atherosclerosis 2000 151 493 9
-
(2000)
Atherosclerosis
, vol.151
, pp. 493-9
-
-
Schmaldienst, S.1
Banyai, S.2
Stulnig, T.M.3
-
20
-
-
0029002364
-
Blood antioxidants (vitamin e and beta-carotene) in long-term low-density lipoprotein apheresis
-
Assogba U Lepage S Bruckert E et al. Blood antioxidants (vitamin E and beta-carotene) in long-term low-density lipoprotein apheresis Clin Chim Acta 1995 235 147 57
-
(1995)
Clin Chim Acta
, vol.235
, pp. 147-57
-
-
Assogba, U.1
Lepage, S.2
Bruckert, E.3
-
21
-
-
0026549150
-
Treatment of children with homozygous familial hypercholesterolemia: Safety and efficacy of low-density lipoprotein apheresis
-
Uauy R Zwiener RJ Phillips MJ Petruska ML Bilheimer DW Treatment of children with homozygous familial hypercholesterolemia: safety and efficacy of low-density lipoprotein apheresis J Pediatr 1992 120 892 8
-
(1992)
J Pediatr
, vol.120
, pp. 892-8
-
-
Uauy, R.1
Zwiener, R.J.2
Phillips, M.J.3
Petruska, M.L.4
Bilheimer, D.W.5
-
23
-
-
0025066184
-
Experience with low-density lipoprotein apheresis by polyclonal and monoclonal anti-apoliprotein B antibodies and by dextran sulfate cellulose
-
Riesen WF Experience with low-density lipoprotein apheresis by polyclonal and monoclonal anti-apoliprotein B antibodies and by dextran sulfate cellulose Curr Stud Hematol Blood Transf 1990 57 208 19
-
(1990)
Curr Stud Hematol Blood Transf
, vol.57
, pp. 208-19
-
-
Riesen, W.F.1
-
24
-
-
0033922444
-
Low density lipoprotein apheresis in treatment of hyperlipidemia: Experience with four different technologies
-
Bambauer R Schiel R Latza R Low density lipoprotein apheresis in treatment of hyperlipidemia: experience with four different technologies Ther Apher 2000 4 213 17
-
(2000)
Ther Apher
, vol.4
, pp. 213-17
-
-
Bambauer, R.1
Schiel, R.2
Latza, R.3
-
25
-
-
0035155170
-
Direct adsorption of lipoproteins from whole blood by DALI apheresis: Technique and effects
-
Bosch T Direct adsorption of lipoproteins from whole blood by DALI apheresis: technique and effects Ther Apher 2001 5 239 43
-
(2001)
Ther Apher
, vol.5
, pp. 239-43
-
-
Bosch, T.1
-
26
-
-
0036246333
-
Effects of direct adsorption of lipoproteins apheresis on lipoproteins, low-density lipoprotein subtypes, and hemorheology in hypercholesterolemic patients with coronary artery disease
-
Otto C Geiss HC Laubach E Schwandt P Effects of direct adsorption of lipoproteins apheresis on lipoproteins, low-density lipoprotein subtypes, and hemorheology in hypercholesterolemic patients with coronary artery disease Ther Apher 2002 6 130 5
-
(2002)
Ther Apher
, vol.6
, pp. 130-5
-
-
Otto, C.1
Geiss, H.C.2
Laubach, E.3
Schwandt, P.4
-
28
-
-
0036917285
-
Direct adsorption of low-density lipoprotein and lipoprotein (a) from whole blood: Results of the first clinical long-term multicenter study using DALI apheresis
-
Direct adsorption of lipoproteins (DALI) study group
-
Bosch T Lennertz A Schenzle D Drager J Direct adsorption of lipoproteins (DALI) study group Direct adsorption of low-density lipoprotein and lipoprotein (a) from whole blood: results of the first clinical long-term multicenter study using DALI apheresis J Clin Apheresis 2002 17 161 9
-
(2002)
J Clin Apheresis
, vol.17
, pp. 161-9
-
-
Bosch, T.1
Lennertz, A.2
Schenzle, D.3
Drager, J.4
|