메뉴 건너뛰기




Volumn 21, Issue 1, 2006, Pages 51-53

Central venous catheterization: Better and worse

Author keywords

[No Author keywords available]

Indexed keywords

ARTERY PUNCTURE; CANNULATION; CATHETER COMPLICATION; CAVA VEIN DISEASE; CENTRAL VENOUS CATHETERIZATION; COMPETENCE; COST EFFECTIVENESS ANALYSIS; ECHOGRAPHY; EDITORIAL; EXPERIENCE; FEMORAL VEIN; HEALTH CARE COST; HEALTH CARE QUALITY; HEART INJURY; HEART RIGHT ATRIUM; HUMAN; INTERNAL JUGULAR VEIN; INVASIVE PROCEDURE; MEDICAL ERROR; MULTIVARIATE ANALYSIS; PATIENT CARE; PATIENT SAFETY; PERFORATION; POSITION; PRIORITY JOURNAL; SUBCLAVIAN VEIN; TEACHING HOSPITAL; VASCULAR ACCESS; VEIN INJURY; VEIN PUNCTURE;

EID: 33644969030     PISSN: 08850666     EISSN: 15251489     Source Type: Journal    
DOI: 10.1177/0885066605281705     Document Type: Editorial
Times cited : (11)

References (24)
  • 2
    • 0024244014 scopus 로고
    • Complications associated with central venous catheters
    • Scott WL. Complications associated with central venous catheters. Chest. 1988;94:1221-1224.
    • (1988) Chest , vol.94 , pp. 1221-1224
    • Scott, W.L.1
  • 3
    • 0019936941 scopus 로고
    • Prospective evaluation of central venous pressure (CVP) catheters in a large city-county hospital
    • Eisenhauer ED, Derveloy RJ, Hasting PR. Prospective evaluation of central venous pressure (CVP) catheters in a large city-county hospital. Ann Surg. 1982;196:560-564.
    • (1982) Ann Surg , vol.196 , pp. 560-564
    • Eisenhauer, E.D.1    Derveloy, R.J.2    Hasting, P.R.3
  • 4
    • 84941817891 scopus 로고
    • Central vein catheterization failure and complication rates by three percutaneous approaches
    • Sznajder JI, Zvebil FR, Bitterman H, et al. Central vein catheterization failure and complication rates by three percutaneous approaches. Arch Intern Med. 1986;146:259-261.
    • (1986) Arch Intern Med , vol.146 , pp. 259-261
    • Sznajder, J.I.1    Zvebil, F.R.2    Bitterman, H.3
  • 5
    • 0027293750 scopus 로고
    • Accurate placement of central venous catheters
    • McGee WT, Ackerman B, Mallory DL. Accurate placement of central venous catheters. Crit Care Med. 1993;21:1118-1123.
    • (1993) Crit Care Med , vol.21 , pp. 1118-1123
    • McGee, W.T.1    Ackerman, B.2    Mallory, D.L.3
  • 6
    • 0028927047 scopus 로고
    • Subclavian venous catheterization: Greater success rate for less experienced operators using ultrasound guidance
    • Gualtieri E, Deppe SA, Sipperly ME, Thompson DR. Subclavian venous catheterization: greater success rate for less experienced operators using ultrasound guidance. Crit Care Med. 1995;23:692-697.
    • (1995) Crit Care Med , vol.23 , pp. 692-697
    • Gualtieri, E.1    Deppe, S.A.2    Sipperly, M.E.3    Thompson, D.R.4
  • 7
    • 0025301215 scopus 로고
    • Ultrasound guidance improves the success rate of internal jugular vein cannulation. A prospective, randomized trial
    • Mallory DL, McGee WT, Shawker TH, et al. Ultrasound guidance improves the success rate of internal jugular vein cannulation. A prospective, randomized trial. Chest. 1990;98:157-160.
    • (1990) Chest , vol.98 , pp. 157-160
    • Mallory, D.L.1    McGee, W.T.2    Shawker, T.H.3
  • 8
    • 0029906824 scopus 로고    scopus 로고
    • Ultrasound guidance for placement of central venous catheters: A meta-analysis of the literature
    • Randolph AG, Cook DJ, Gonzales CA, Pribble CG. Ultrasound guidance for placement of central venous catheters: a meta-analysis of the literature. Crit Care Med. 1996;24:2053-2058.
    • (1996) Crit Care Med , vol.24 , pp. 2053-2058
    • Randolph, A.G.1    Cook, D.J.2    Gonzales, C.A.3    Pribble, C.G.4
  • 9
    • 0028833852 scopus 로고
    • Facilitation of internal jugular venous cannulation using an audio-guided Doppler ultrasound vascular access device: Results from a prospective dual-center, randomized, crossover clinical study
    • Gilbert TB, Seneff MG, Becker RB. Facilitation of internal jugular venous cannulation using an audio-guided Doppler ultrasound vascular access device: results from a prospective dual-center, randomized, crossover clinical study. Crit Care Med. 1995;23:60-65.
    • (1995) Crit Care Med , vol.23 , pp. 60-65
    • Gilbert, T.B.1    Seneff, M.G.2    Becker, R.B.3
  • 10
    • 33644974623 scopus 로고    scopus 로고
    • Safe placement of central venous catheters
    • McGee WT, Martin RT. Safe placement of central venous catheters. Crit Care Med. 1999;27:A47.
    • (1999) Crit Care Med , vol.27
    • McGee, W.T.1    Martin, R.T.2
  • 11
    • 0030057557 scopus 로고    scopus 로고
    • Accurate placement of central venous catheters: A follow-up using 16cm catheters
    • McGee WT, Moriarty KP. Accurate placement of central venous catheters: a follow-up using 16cm catheters. J Intensive Care Med. 1996:11:19-22.
    • (1996) J Intensive Care Med , vol.11 , pp. 19-22
    • McGee, W.T.1    Moriarty, K.P.2
  • 12
    • 0024996909 scopus 로고
    • Positioning central venous catheters: A prospective study
    • Peres PW. Positioning central venous catheters: a prospective study. Anaesth Intensive Care. 1990;18:536-539.
    • (1990) Anaesth Intensive Care , vol.18 , pp. 536-539
    • Peres, P.W.1
  • 13
    • 0021749284 scopus 로고
    • Cardiac tamponade from central venous catheters - Report of a case and review of the English literature
    • Collier PE, Ryan JJ, Diamond DL. Cardiac tamponade from central venous catheters - report of a case and review of the English literature. Angiology. 1984;35:595-600.
    • (1984) Angiology , vol.35 , pp. 595-600
    • Collier, P.E.1    Ryan, J.J.2    Diamond, D.L.3
  • 15
    • 0003198973 scopus 로고
    • Precautions necessary with central venous catheters
    • FDA Task Force. July
    • Food and Drug Administration. Precautions necessary with central venous catheters. FDA Task Force. FDA Drug Bulletin. July 1989;15-16.
    • (1989) FDA Drug Bulletin , pp. 15-16
  • 18
    • 0022642678 scopus 로고
    • Impending catheter perforation of superior vena cava: Radiographic recognition
    • Tocino IM, Watanabe A: Impending catheter perforation of superior vena cava: radiographic recognition. Am J Roentgenol. 1986;146:487-490.
    • (1986) Am J Roentgenol , vol.146 , pp. 487-490
    • Tocino, I.M.1    Watanabe, A.2
  • 19
    • 0013080658 scopus 로고    scopus 로고
    • Making health care safer - A critical analysis of patient safety practices: Summary
    • Rothschild JM, ed. (Agency for Healthcare Research and Quality. Evidence Report/Technology Assessment). Rockville, Md: AHRQ Publications
    • Making health care safer - a critical analysis of patient safety practices: summary. In: Rothschild JM, ed. Ultrasound Guidance of Central Vein Catheterization (Agency for Healthcare Research and Quality. Evidence Report/Technology Assessment). Rockville, Md: AHRQ Publications; 2001:43.
    • (2001) Ultrasound Guidance of Central Vein Catheterization , pp. 43
  • 20
    • 85045797317 scopus 로고    scopus 로고
    • The effectiveness and cost-effectiveness of ultrasound locating devices for central venous access: A systematic review and economic evaluation
    • The effectiveness and cost-effectiveness of ultrasound locating devices for central venous access: a systematic review and economic evaluation. Health Technology Assessment. 2003;7(12):19-27.
    • (2003) Health Technology Assessment , vol.7 , Issue.12 , pp. 19-27
  • 21
    • 33644971760 scopus 로고    scopus 로고
    • Bard Access Systems Salt Lake City, UT
    • Site-Rite Ultrasound Systems. Bard Access Systems Salt Lake City, UT. Available at: www.dymax-usa.com/products.html. Accessed October 14, 2005.
  • 22
    • 0034183202 scopus 로고    scopus 로고
    • A systemic approach to teaching insertion of a central venous line
    • Nip IL, Haruno MM.A systemic approach to teaching insertion of a central venous line. Acad Med. 2000;75:552.
    • (2000) Acad Med , vol.75 , pp. 552
    • Nip, I.L.1    Haruno, M.M.2
  • 23
    • 0038348613 scopus 로고    scopus 로고
    • Training fourth-year medical students in critical invasive skills improves subsequent patient safety
    • Martin M, Scalabrini B, Rioux A, Xhignesse M-A. Training fourth-year medical students in critical invasive skills improves subsequent patient safety. Am Surg. 2003;69:437-440.
    • (2003) Am Surg , vol.69 , pp. 437-440
    • Martin, M.1    Scalabrini, B.2    Rioux, A.3    Xhignesse, M.-A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.