-
2
-
-
0017150067
-
The capability of fluoroscopic systems for the production of computerized axial tomograms
-
N.A. Baily, R.A. Keller, C.W. Jacowatz The capability of fluoroscopic systems for the production of computerized axial tomograms Invest. Radiol. 11 1976 434 439
-
(1976)
Invest. Radiol.
, vol.11
, pp. 434-439
-
-
Baily, N.A.1
Keller, R.A.2
Jacowatz, C.W.3
-
3
-
-
0017002830
-
Possible application of a radiotherapy simulator for imaging of body cross-sections
-
R.M. Harrison, F.T. Farmer Possible application of a radiotherapy simulator for imaging of body cross-sections Br. J. Radiol. 49 1976 813
-
(1976)
Br. J. Radiol.
, vol.49
, pp. 813
-
-
Harrison, R.M.1
Farmer, F.T.2
-
4
-
-
0017625866
-
Computerized tomography using video recorded fluoroscopic images
-
A.C. Kak, C.V. Jakowatz Jr, N.A. Baily Computerized tomography using video recorded fluoroscopic images IEEE Trans. Biomed. Eng 24 1977 157 169
-
(1977)
IEEE Trans. Biomed. Eng
, vol.24
, pp. 157-169
-
-
Kak, A.C.1
Jakowatz C.V. Jr2
Baily, N.A.3
-
5
-
-
0017899102
-
The determination of anatomical cross sections using a radiotherapy simulator
-
R.M. Harrison, F.T. Farmer The determination of anatomical cross sections using a radiotherapy simulator Br. J. Radiol. 51 1978 448 453
-
(1978)
Br. J. Radiol.
, vol.51
, pp. 448-453
-
-
Harrison, R.M.1
Farmer, F.T.2
-
6
-
-
0021264428
-
Investigations using an X-ray image intensifier and a TV camera for imaging transverse sections in humans
-
R.N. Arnot, R.J. Willetts, J.R. Batten Investigations using an X-ray image intensifier and a TV camera for imaging transverse sections in humans Br. J. Radiol. 57 1984 47 55
-
(1984)
Br. J. Radiol.
, vol.57
, pp. 47-55
-
-
Arnot, R.N.1
Willetts, R.J.2
Batten, J.R.3
-
9
-
-
33644940610
-
Single-scan volume CT with a radiotherapy simulator
-
P.S. Cho, T.W. Griffin Single-scan volume CT with a radiotherapy simulator Med. Phys. 20 1993 1292
-
(1993)
Med. Phys.
, vol.20
, pp. 1292
-
-
Cho, P.S.1
Griffin, T.W.2
-
12
-
-
0031790660
-
A cone-beam megavoltage CT scanner for treatment verification in conformal radiotherapy
-
M.A. Mosleh-Shirazi, P.M. Evans, W. Swindell A cone-beam megavoltage CT scanner for treatment verification in conformal radiotherapy Radiother. Oncol. 48 1998 319 328
-
(1998)
Radiother. Oncol.
, vol.48
, pp. 319-328
-
-
Mosleh-Shirazi, M.A.1
Evans, P.M.2
Swindell, W.3
-
13
-
-
0031735489
-
Tomotherapeutic portal imaging for radiation treatment verification
-
B.M. Hesse, L. Spies, B.A. Groh Tomotherapeutic portal imaging for radiation treatment verification Phys. Med. Biol. 43 1998 3607 3616
-
(1998)
Phys. Med. Biol.
, vol.43
, pp. 3607-3616
-
-
Hesse, B.M.1
Spies, L.2
Groh, B.A.3
-
14
-
-
0031935731
-
A feasibility study for megavoltage cone beam CT using commercial EPID
-
S. Midgley, R.M. Millar, J.A. Dudson A feasibility study for megavoltage cone beam CT using commercial EPID Phys. Med. Biol. 43 1998 155 169
-
(1998)
Phys. Med. Biol.
, vol.43
, pp. 155-169
-
-
Midgley, S.1
Millar, R.M.2
Dudson, J.A.3
-
15
-
-
0031719485
-
Feasibility of megavoltage portal CT using an electronic portal imaging device (EPID) and a multi-level scheme algebraic reconstruction technique (MLS-ART)
-
H. Guan, Y. Zhu Feasibility of megavoltage portal CT using an electronic portal imaging device (EPID) and a multi-level scheme algebraic reconstruction technique (MLS-ART) Phys. Med. Biol. 43 1998 2925 2937
-
(1998)
Phys. Med. Biol.
, vol.43
, pp. 2925-2937
-
-
Guan, H.1
Zhu, Y.2
-
16
-
-
0037360947
-
Megavoltage cone-beam computed tomography using a high-efficiency image receptor
-
E.J. Seppi, P. Munro, S.W. Johnsen Megavoltage cone-beam computed tomography using a high-efficiency image receptor Int. J. Radiat. Oncol. Biol. Phys. 55 2003 793 803
-
(2003)
Int. J. Radiat. Oncol. Biol. Phys.
, vol.55
, pp. 793-803
-
-
Seppi, E.J.1
Munro, P.2
Johnsen, S.W.3
-
18
-
-
0032866087
-
A radiographic and tomographic imaging system integrated into a medical linear accelerator for localization of bone and soft-tissue targets
-
D.A. Jaffray, D.G. Drake, M. Moreau A radiographic and tomographic imaging system integrated into a medical linear accelerator for localization of bone and soft-tissue targets Int. J. Radiat. Oncol. Biol. Phys. 45 1999 773 789
-
(1999)
Int. J. Radiat. Oncol. Biol. Phys.
, vol.45
, pp. 773-789
-
-
Jaffray, D.A.1
Drake, D.G.2
Moreau, M.3
-
19
-
-
0034086714
-
Cone-beam tomography with a flat panel imager: Initial performance characterization
-
D.A. Jaffray, J.H. Siewerdsen Cone-beam tomography with a flat panel imager Initial performance characterization Med. Phys. 27 2000 1311 1323
-
(2000)
Med. Phys.
, vol.27
, pp. 1311-1323
-
-
Jaffray, D.A.1
Siewerdsen, J.H.2
-
20
-
-
0035110308
-
Cone-beam tomography with a flat panel imager: Magnitude and effects of x-ray scatter
-
J.H. Siewerdsen, D.A. Jaffray Cone-beam tomography with a flat panel imager Magnitude and effects of x-ray scatter Med. Phys 28 2001 220 231
-
(2001)
Med. Phys
, vol.28
, pp. 220-231
-
-
Siewerdsen, J.H.1
Jaffray, D.A.2
-
22
-
-
0942277196
-
Integrated radiotherapy imaging system (IRIS): Design considerations of tumour tracking with linac gantry-mounted diagnostic x-ray systems with flat-panel detectors
-
R.I. Berbeco, S.B. Jiang, G.C. Sharp Integrated radiotherapy imaging system (IRIS) Design considerations of tumour tracking with linac gantry-mounted diagnostic x-ray systems with flat-panel detectors Phys. Med. Biol. 49 2004 243 255
-
(2004)
Phys. Med. Biol.
, vol.49
, pp. 243-255
-
-
Berbeco, R.I.1
Jiang, S.B.2
Sharp, G.C.3
-
23
-
-
0032240404
-
A new volumetric CT machine for dental imaging based on the cone-beam technique: preliminary results
-
P. Mozzo, C. Procacci, A. Tacconi A new volumetric CT machine for dental imaging based on the cone-beam technique preliminary results Eur. Radiol. 8 1998 1558 1564
-
(1998)
Eur. Radiol.
, vol.8
, pp. 1558-1564
-
-
Mozzo, P.1
Procacci, C.2
Tacconi, A.3
-
24
-
-
0034843526
-
Introduction of a new mobile C-arm/CT combination equipment (ISO-C-3D). Initial results of 3-D sectional imaging
-
C. Rock, U. Linsenmaier, R. Brandl Introduction of a new mobile C-arm/CT combination equipment (ISO-C-3D). Initial results of 3-D sectional imaging Unfallchirurg 104 2001 827 833
-
(2001)
Unfallchirurg
, vol.104
, pp. 827-833
-
-
Rock, C.1
Linsenmaier, U.2
Brandl, R.3
-
25
-
-
0036082380
-
Three-dimensional CT with a modified C-arm image intensifier: Feasibility
-
U. Linsenmaier, C. Rock, E. Euler Three-dimensional CT with a modified C-arm image intensifier Feasibility Radiology 224 2002 286 292
-
(2002)
Radiology
, vol.224
, pp. 286-292
-
-
Linsenmaier, U.1
Rock, C.2
Euler, E.3
-
26
-
-
1242331911
-
C-arm-based three-dimensional navigation: A preliminary feasibility study
-
E. Euler, S. Heining, C. Riquarts C-arm-based three-dimensional navigation A preliminary feasibility study Comput. Aided Surg. 8 2003 35 41
-
(2003)
Comput. Aided Surg.
, vol.8
, pp. 35-41
-
-
Euler, E.1
Heining, S.2
Riquarts, C.3
-
27
-
-
17644373095
-
Intraoperative three-dimensional imaging with a motorized mobile C-arm (SIREMOBIL ISO-C-3D) in foot and ankle trauma care: A preliminary report
-
M. Richter, J. Geerling, S. Zech Intraoperative three-dimensional imaging with a motorized mobile C-arm (SIREMOBIL ISO-C-3D) in foot and ankle trauma care A preliminary report J. Orthop. Trauma 19 2005 259 266
-
(2005)
J. Orthop. Trauma
, vol.19
, pp. 259-266
-
-
Richter, M.1
Geerling, J.2
Zech, S.3
-
28
-
-
5044242309
-
Intraoperative 3D imaging of the facial skeleton using the SIREMOBILE Iso-C3D
-
M. Heiland, R. Schmelzle, A. Hebecker Intraoperative 3D imaging of the facial skeleton using the SIREMOBILE Iso-C3D Dentomaxillofacial Rad. 33 2004 130 132
-
(2004)
Dentomaxillofacial Rad.
, vol.33
, pp. 130-132
-
-
Heiland, M.1
Schmelzle, R.2
Hebecker, A.3
-
29
-
-
5044251144
-
Radiation exposure during midfacial imaging using 4- and 16- slice computed tomography, cone beam computed tomography systems and conventional radiography
-
D. Schulze, M. Heiland, H. Thurmann, G. Adam Radiation exposure during midfacial imaging using 4- and 16- slice computed tomography, cone beam computed tomography systems and conventional radiography Dentomaxillofacial Rad. 33 2004 83 86
-
(2004)
Dentomaxillofacial Rad.
, vol.33
, pp. 83-86
-
-
Schulze, D.1
Heiland, M.2
Thurmann, H.3
Adam, G.4
-
30
-
-
2342535057
-
Intraopertative Iso-C C-arm navigation in craniospinal surgery: The first 60 cases
-
J.S. Hott, V.R. Deshmukh, J.D. Klopfenstein Intraopertative Iso-C C-arm navigation in craniospinal surgery The first 60 cases Neurosurgery 54 2004 1131 1136
-
(2004)
Neurosurgery
, vol.54
, pp. 1131-1136
-
-
Hott, J.S.1
Deshmukh, V.R.2
Klopfenstein, J.D.3
-
31
-
-
4544356560
-
3D imaging with an isocentric mobile C-arm: Comparison of image quality with spiral CT
-
D. Kotsianos, S. Wirth, T. Fischer 3D imaging with an isocentric mobile C-arm Comparison of image quality with spiral CT Eur. Radiol. 14 2004 1590 1595
-
(2004)
Eur. Radiol.
, vol.14
, pp. 1590-1595
-
-
Kotsianos, D.1
Wirth, S.2
Fischer, T.3
-
32
-
-
33644959217
-
Evaluation of a C-arm cone beam device for use in image guided radiotherapy
-
B.Y. Yi Jeong Publishing Seoul *et al.
-
P.E. Chow, S. Tenn, N. Wink Evaluation of a C-arm cone beam device for use in image guided radiotherapy B.Y. Yi The Use of Computers in Radiation Therapy 2004 Jeong Publishing Seoul 637 639
-
(2004)
The Use of Computers in Radiation Therapy
, pp. 637-639
-
-
Chow, P.E.1
Tenn, S.2
Wink, N.3
-
33
-
-
12844254281
-
Volume CT with a flat-panel detector on a mobile, isocentric C-arm: Pre-clinical investigation in guidance of minimally invasive surgery
-
J.H. Siewerdsen, D.J. Moseley, S. Burch Volume CT with a flat-panel detector on a mobile, isocentric C-arm Pre-clinical investigation in guidance of minimally invasive surgery Med. Phys. 32 2005 241 254
-
(2005)
Med. Phys.
, vol.32
, pp. 241-254
-
-
Siewerdsen, J.H.1
Moseley, D.J.2
Burch, S.3
-
34
-
-
0004293868
-
-
4th ed. American Society of Photogrammetry Falls Church
-
C.C. Slama The Manual of Photogrammetry 4th ed. 1980 American Society of Photogrammetry Falls Church
-
(1980)
The Manual of Photogrammetry
-
-
Slama, C.C.1
-
36
-
-
0036857027
-
Motion tracking: No silver bullet, but a respectable arsenal
-
G. Welch, E. Foxlin Motion tracking No silver bullet, but a respectable arsenal IEEE Comp. Graph. Appl. 22 2002 24 38
-
(2002)
IEEE Comp. Graph. Appl.
, vol.22
, pp. 24-38
-
-
Welch, G.1
Foxlin, E.2
-
37
-
-
0026137964
-
Least-squares estimation of transformation parameters between 2 point patterns
-
S. Umeyama Least-squares estimation of transformation parameters between 2 point patterns IEEE Trans. Pattern Analysis Machine Intell. 13 1991 376 380
-
(1991)
IEEE Trans. Pattern Analysis Machine Intell.
, vol.13
, pp. 376-380
-
-
Umeyama, S.1
-
38
-
-
0027991368
-
Photogrammetric accuracy measurements of head holder systems used for fractionated radiotherapy
-
M. Menke, F. Hirschfeld, T. Mack Photogrammetric accuracy measurements of head holder systems used for fractionated radiotherapy Int. J. Radiat. Oncol. Biol. Phys. 29 1994 1147 1155
-
(1994)
Int. J. Radiat. Oncol. Biol. Phys.
, vol.29
, pp. 1147-1155
-
-
Menke, M.1
Hirschfeld, F.2
Mack, T.3
-
39
-
-
0030792574
-
The University of Florida frameless high-precision stereotactic radiotherapy system
-
F.J. Bova, J.M. Buatti, W.A. Friedman The University of Florida frameless high-precision stereotactic radiotherapy system Int. J. Radiat. Oncol. Biol. Phys 38 1997 875 882
-
(1997)
Int. J. Radiat. Oncol. Biol. Phys
, vol.38
, pp. 875-882
-
-
Bova, F.J.1
Buatti, J.M.2
Friedman, W.A.3
-
40
-
-
0027142980
-
Stereotaxically guided fractionated radiotherapy - Technical aspects
-
W. Schlegel, O. Pastyr, T. Bortfeld Stereotaxically guided fractionated radiotherapy - Technical aspects Radiother. Oncol 29 1993 197 204
-
(1993)
Radiother. Oncol
, vol.29
, pp. 197-204
-
-
Schlegel, W.1
Pastyr, O.2
Bortfeld, T.3
-
41
-
-
20644446492
-
Optically guided patient positioning techniques. Semin
-
S.L. Meeks, W.A. Tome, T.R. Willoughby Optically guided patient positioning techniques. Semin Radiat. Oncol 15 2005 192 201
-
(2005)
Radiat. Oncol
, vol.15
, pp. 192-201
-
-
Meeks, S.L.1
Tome, W.A.2
Willoughby, T.R.3
-
43
-
-
0036852607
-
An evaluation of gating window size, delivery method, and composite field dosimetry of respiratory-gated IMRT
-
G.D. Hugo, N. Agazaryan, T.D. Solberg An evaluation of gating window size, delivery method, and composite field dosimetry of respiratory-gated IMRT Med. Phys. 29 2002 2517 2525
-
(2002)
Med. Phys.
, vol.29
, pp. 2517-2525
-
-
Hugo, G.D.1
Agazaryan, N.2
Solberg, T.D.3
-
44
-
-
0031803931
-
Improvement of CT-based treatment-planning models of abdominal targets using static exhale imaging
-
J.M. Balter, K.L. Lam, C.J. McGinn Improvement of CT-based treatment-planning models of abdominal targets using static exhale imaging Int. J. Radiat. Oncol. Biol. Phys. 41 1998 939 943
-
(1998)
Int. J. Radiat. Oncol. Biol. Phys.
, vol.41
, pp. 939-943
-
-
Balter, J.M.1
Lam, K.L.2
McGinn, C.J.3
-
45
-
-
0032941481
-
A method for incorporating organ motion due to breathing into 3D dose calculations
-
A.E. Lujan, E.W. Larsen, J.M. Balter A method for incorporating organ motion due to breathing into 3D dose calculations Med. Phys. 26 1999 715 720
-
(1999)
Med. Phys.
, vol.26
, pp. 715-720
-
-
Lujan, A.E.1
Larsen, E.W.2
Balter, J.M.3
-
46
-
-
0142089327
-
A method for incorporating organ motion due to breathing into 3D dose calculations in the liver: Sensitivity to variations in motion
-
A.E. Lujan, J.M. Balter, R.K. Ten Haken A method for incorporating organ motion due to breathing into 3D dose calculations in the liver Sensitivity to variations in motion Med. Phys. 30 2003 2643 2649
-
(2003)
Med. Phys.
, vol.30
, pp. 2643-2649
-
-
Lujan, A.E.1
Balter, J.M.2
Ten Haken, R.K.3
-
47
-
-
0038377254
-
The effects of tumor motion on planning and delivery of respiratory-gated IMRT
-
G.D. Hugo, N. Agazaryan, T.D. Solberg The effects of tumor motion on planning and delivery of respiratory-gated IMRT Med. Phys. 30 2003 1052 1066
-
(2003)
Med. Phys.
, vol.30
, pp. 1052-1066
-
-
Hugo, G.D.1
Agazaryan, N.2
Solberg, T.D.3
-
48
-
-
77049180654
-
Movements of the thoracic cage and diaphragm in respiration
-
O.L. Wade Movements of the thoracic cage and diaphragm in respiration J. Physiol. 124 1954 193 212
-
(1954)
J. Physiol.
, vol.124
, pp. 193-212
-
-
Wade, O.L.1
-
50
-
-
0037086333
-
Investigations of a minimally invasive method for treatment of spinal malignancies with LINAC stereotactic radiation therapy: Accuracy and animal studies
-
P.M. Medin, T.D. Solberg, A.A.F. DeSalles Investigations of a minimally invasive method for treatment of spinal malignancies with LINAC stereotactic radiation therapy Accuracy and animal studies Int. J. Radiat. Oncol. Biol. Phys. 52 2002 1111 1122
-
(2002)
Int. J. Radiat. Oncol. Biol. Phys.
, vol.52
, pp. 1111-1122
-
-
Medin, P.M.1
Solberg, T.D.2
DeSalles, A.A.F.3
-
51
-
-
27644595337
-
Retrospectively respiratory gated cone beam computed tomography
-
S. Kriminski, M. Mitschke, S. Sorensen Retrospectively respiratory gated cone beam computed tomography Phys. Med. Biol. 50 2005 5263 5280
-
(2005)
Phys. Med. Biol.
, vol.50
, pp. 5263-5280
-
-
Kriminski, S.1
Mitschke, M.2
Sorensen, S.3
-
52
-
-
14844333135
-
Prostate motion and isocenter adjustment from ultrasound-based localization during delivery of radiation therapy
-
A.Y. Fung, C.A. Enke, K.M. Ayyangar Prostate motion and isocenter adjustment from ultrasound-based localization during delivery of radiation therapy Int. J. Radiat. Oncol. Biol. Phys. 61 2005 984 992
-
(2005)
Int. J. Radiat. Oncol. Biol. Phys.
, vol.61
, pp. 984-992
-
-
Fung, A.Y.1
Enke, C.A.2
Ayyangar, K.M.3
-
53
-
-
3042557893
-
Daily ultrasound-based image-guided targeting for radiotherapy of upper abdominal malignancies
-
M. Fuss, B.J. Salter, S.X. Cavanaugh Daily ultrasound-based image-guided targeting for radiotherapy of upper abdominal malignancies Int. J. Radiat. Oncol. Biol. Phys. 59 2004 1245 1256
-
(2004)
Int. J. Radiat. Oncol. Biol. Phys.
, vol.59
, pp. 1245-1256
-
-
Fuss, M.1
Salter, B.J.2
Cavanaugh, S.X.3
-
54
-
-
2942545968
-
Acquiring 4D thoracic CT scans using a multislice helical method
-
P.J. Keall, G. Starkschall, H. Shukla Acquiring 4D thoracic CT scans using a multislice helical method Phys. Med. Biol. 49 2004 2053 2067
-
(2004)
Phys. Med. Biol.
, vol.49
, pp. 2053-2067
-
-
Keall, P.J.1
Starkschall, G.2
Shukla, H.3
-
55
-
-
10744222972
-
A method for the reconstruction of four-dimensional synchronized CT scans acquired during free breathing
-
D.A. Low, M. Nystrom, E. Kalinin A method for the reconstruction of four-dimensional synchronized CT scans acquired during free breathing Med. Phys. 30 2003 1254 1263
-
(2003)
Med. Phys.
, vol.30
, pp. 1254-1263
-
-
Low, D.A.1
Nystrom, M.2
Kalinin, E.3
-
56
-
-
17844379268
-
Quantitation of the reconstruction quality of a four-dimensional computed tomography process for lung cancer patients
-
W. Lu, P.J. Parikh, I.M. El Naqa Quantitation of the reconstruction quality of a four-dimensional computed tomography process for lung cancer patients Med. Phys. 32 2005 890 901
-
(2005)
Med. Phys.
, vol.32
, pp. 890-901
-
-
Lu, W.1
Parikh, P.J.2
El Naqa, I.M.3
-
57
-
-
1242338927
-
4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT
-
T. Pan, T.-Y. Lee, E. Rietzel 4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT Med. Phys. 31 2004 333 340
-
(2004)
Med. Phys.
, vol.31
, pp. 333-340
-
-
Pan, T.1
Lee, T.-Y.2
Rietzel, E.3
-
58
-
-
0037422708
-
Acquiring a four-dimensional computed tomography dataset using an external respiratory signal
-
S.S. Vedam, P.J. Keall, V.R. Kini Acquiring a four-dimensional computed tomography dataset using an external respiratory signal Phys. Med. Biol. 48 2003 45 62
-
(2003)
Phys. Med. Biol.
, vol.48
, pp. 45-62
-
-
Vedam, S.S.1
Keall, P.J.2
Kini, V.R.3
|