메뉴 건너뛰기




Volumn 64, Issue 5, 2006, Pages 608-614

Correction factors for the INER-improved free-air ionization chambers calculated with the Monte Carlo method

Author keywords

Electron loss; Free air ionization chamber; Monte Carlo; Scattered photons

Indexed keywords

ELECTRONS; MONTE CARLO METHODS; PHOTONS; SCATTERING; X RAYS;

EID: 33644924873     PISSN: 09698043     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.apradiso.2005.12.009     Document Type: Article
Times cited : (22)

References (17)
  • 3
    • 33646865650 scopus 로고
    • Comparison of exposure standards in the 10-50 kV X-ray region
    • M. Boutillon, W.H. Henry, and P.J. Lamperti Comparison of exposure standards in the 10-50 kV X-ray region Metrologia 5 1969 1 11
    • (1969) Metrologia , vol.5 , pp. 1-11
    • Boutillon, M.1    Henry, W.H.2    Lamperti, P.J.3
  • 7
    • 0032625868 scopus 로고    scopus 로고
    • Improved free-air ionization chamber for the measurement of X-rays
    • W.L. Chen, S.H. Su, L.L. Su, and W.S. Hwang Improved free-air ionization chamber for the measurement of X-rays Metrologia 36 1999 19 24
    • (1999) Metrologia , vol.36 , pp. 19-24
    • Chen, W.L.1    Su, S.H.2    Su, L.L.3    Hwang, W.S.4
  • 9
    • 0031795046 scopus 로고    scopus 로고
    • Correction factors for the NMI free-air ionization chamber for medium-energy X-rays calculated with the Monte Carlo method
    • T.W.M. Grimbergen, E.V. Dijk, and W.D. Vries Correction factors for the NMI free-air ionization chamber for medium-energy X-rays calculated with the Monte Carlo method Phys. Med. Biol. 43 1998 3207 3224
    • (1998) Phys. Med. Biol. , vol.43 , pp. 3207-3224
    • Grimbergen, T.W.M.1    Dijk, E.V.2    Vries, W.D.3
  • 12
    • 9544222624 scopus 로고    scopus 로고
    • The performance of the INER improved free-air ionization chamber in the comparison of air kerma calibration coefficients for medium-energy X-rays
    • J.H. Lee, L.H. Kotler, L. Büermann, W.S. Hwang, J.H. Chiu, and C.F. Wang The performance of the INER improved free-air ionization chamber in the comparison of air kerma calibration coefficients for medium-energy X-rays Radiat. Meas. 39 2005 1 10
    • (2005) Radiat. Meas. , vol.39 , pp. 1-10
    • Lee, J.H.1    Kotler, L.H.2    Büermann, L.3    Hwang, W.S.4    Chiu, J.H.5    Wang, C.F.6
  • 14
    • 0032171260 scopus 로고    scopus 로고
    • Improvements of low-energy photon transport in EGS4
    • Y. Namito, H. Hirayama, and S. Ban Improvements of low-energy photon transport in EGS4 Radiat. Phys. Chem. 53 1998 283 294
    • (1998) Radiat. Phys. Chem. , vol.53 , pp. 283-294
    • Namito, Y.1    Hirayama, H.2    Ban, S.3
  • 17
    • 48349135154 scopus 로고
    • National Bureau Standards Handbook, No. 64. US Government Printing Office Washington, DC
    • H.O. Wyckoff, and F.H. Attix Design of Free-Air Ionization Chambers 1969 National Bureau Standards Handbook, No. 64. US Government Printing Office Washington, DC pp. 1-16
    • (1969) Design of Free-Air Ionization Chambers
    • Wyckoff, H.O.1    Attix, F.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.