메뉴 건너뛰기




Volumn 52, Issue 2, 2006, Pages 132-136

Can we cure atrial flutter with radiofrequency ablation in an hour?;Je možné vyléčit typický flutter síní radiofrekvenční ablací do jedné hodiny?

Author keywords

Common atrial flutter; Irrigated tip catheter; Radiofrequency ablation

Indexed keywords

ADULT; AGED; ARTICLE; FEMALE; HEART ATRIUM FIBRILLATION; HEART ATRIUM FLUTTER; HEART DISEASE; HUMAN; MAJOR CLINICAL STUDY; MALE; RADIOFREQUENCY ABLATION; THORAX PAIN; TREATMENT OUTCOME; CATHETER ABLATION; CLINICAL TRIAL; ELECTROCARDIOGRAPHY; INSTRUMENTATION; METHODOLOGY; MIDDLE AGED; MULTICENTER STUDY; TIME;

EID: 33644902374     PISSN: 0042773X     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (2)

References (15)
  • 2
    • 9444295300 scopus 로고    scopus 로고
    • Role of the tricuspid annulus and the Eustachian valve/ridge on atrial flutter
    • Nakagawa H, Lazzara R, Khastgir T et al. Role of the tricuspid annulus and the Eustachian valve/ridge on atrial flutter. Circulation 1996; 94: 407-424.
    • (1996) Circulation , vol.94 , pp. 407-424
    • Nakagawa, H.1    Lazzara, R.2    Khastgir, T.3
  • 3
    • 0025603101 scopus 로고
    • Demonstration of an area of slow conduction in human atrial flutter
    • Olshansky B, Okumura K, Hess PG et al. Demonstration of an area of slow conduction in human atrial flutter. J Am Coll Cardiol 1990; 16: 1639-1648.
    • (1990) J Am Coll Cardiol , vol.16 , pp. 1639-1648
    • Olshansky, B.1    Okumura, K.2    Hess, P.G.3
  • 4
    • 33644918260 scopus 로고    scopus 로고
    • Zahájení antiarytmické léčby - Bezpečnost a možnosti. Hospitalizační versus ambulantní zahájení
    • Heine P, Lukl J, Fiala M et al. Zahájení antiarytmické léčby - bezpečnost a možnosti. Hospitalizační versus ambulantní zahájení. Kardiol Rev 2001; 3: 150-154.
    • (2001) Kardiol Rev , vol.3 , pp. 150-154
    • Heine, P.1    Lukl, J.2    Fiala, M.3
  • 5
    • 33644927207 scopus 로고    scopus 로고
    • Supraventrikulární tachyarytmie
    • Špinar J, Vítovec J. Praha: Grada Publishing
    • Novák M, Mullerová J. Supraventrikulární tachyarytmie. In: Špinar J, Vítovec J. Ischemická choroba srdeční. Praha: Grada Publishing 2003: 203-212.
    • (2003) Ischemická Choroba Srdeční , pp. 203-212
    • Novák, M.1    Mullerová, J.2
  • 6
    • 0027534580 scopus 로고
    • Radiofrequency ablation of the inferior vena cava-tricuspid valve isthmus in common atrial flutter
    • Cosio FG, Lopez-Gil M, Giocolea A et al. Radiofrequency ablation of the inferior vena cava-tricuspid valve isthmus in common atrial flutter. Am J Cardiol 1993; 71: 705-709.
    • (1993) Am J Cardiol , vol.71 , pp. 705-709
    • Cosio, F.G.1    Lopez-Gil, M.2    Giocolea, A.3
  • 7
    • 8044248430 scopus 로고    scopus 로고
    • Radiofrequency catheter ablation of common atrial flutter in 200 patients
    • Fischer B, Jad's P, Shah DC et al. Radiofrequency catheter ablation of common atrial flutter in 200 patients. J Cardiovasc Electrophysiol 1996; 7: 1225-1233.
    • (1996) J Cardiovasc Electrophysiol , vol.7 , pp. 1225-1233
    • Fischer, B.1    Jad's, P.2    Shah, D.C.3
  • 8
    • 15644363824 scopus 로고    scopus 로고
    • Long term outcome of radiofrequency catheter ablation for typical atrial flutter: Risk prediction of reccurent arrhytmias
    • Tai CT, Chen SA, Chiang CE et al. Long term outcome of radiofrequency catheter ablation for typical atrial flutter: Risk prediction of reccurent arrhytmias. J Cardiovasc Electrophysiol 1998; 9: 115-129.
    • (1998) J Cardiovasc Electrophysiol , vol.9 , pp. 115-129
    • Tai, C.T.1    Chen, S.A.2    Chiang, C.E.3
  • 9
    • 0031795163 scopus 로고    scopus 로고
    • The architecture of the atrial musculature between the orifice of the inferior caval vein and the tricuspid valve: The anatomy of the isthmus
    • Cabrera JA, Sanchez-Quintana D, Ho SY et al. The architecture of the atrial musculature between the orifice of the inferior caval vein and the tricuspid valve: The anatomy of the isthmus. J Cardiovasc Electrophysiol 1998; 9: 1186-1195.
    • (1998) J Cardiovasc Electrophysiol , vol.9 , pp. 1186-1195
    • Cabrera, J.A.1    Sanchez-Quintana, D.2    Ho, S.Y.3
  • 10
    • 0344447087 scopus 로고    scopus 로고
    • Successful irrigated tip catheter ablation of atrial flutter resistant to conventional radiofrequency ablation
    • Jad's P, Had'ssaguerre M, Shah DC et al. Successful irrigated tip catheter ablation of atrial flutter resistant to conventional radiofrequency ablation. Circulation 1998; 98: 835-838.
    • (1998) Circulation , vol.98 , pp. 835-838
    • Jad's, P.1    Had'ssaguerre, M.2    Shah, D.C.3
  • 11
    • 0034700269 scopus 로고    scopus 로고
    • Efficacy and safety of an irrigated-tip catheter for the ablation of accessory pathways resistant to conventional radiofrequency ablation
    • Yamane T, Jais P, Shah DC Efficacy and Safety of an Irrigated-Tip Catheter for the Ablation of Accessory Pathways Resistant to Conventional Radiofrequency Ablation. Circulation 2000; 102: 2565-2568.
    • (2000) Circulation , vol.102 , pp. 2565-2568
    • Yamane, T.1    Jais, P.2    Shah, D.C.3
  • 12
    • 0342470431 scopus 로고    scopus 로고
    • Prospective randomized comparison of irrigated-tip versus conventional-tip catheters for ablation of common flutter
    • Jad's P, Shah DC, Had'ssaguerre M et al. Prospective randomized comparison of irrigated-tip versus conventional-tip catheters for ablation of common flutter. Circulation 2000; 101: 772-777.
    • (2000) Circulation , vol.101 , pp. 772-777
    • Jad's, P.1    Shah, D.C.2    Had'ssaguerre, M.3
  • 13
    • 33644902891 scopus 로고    scopus 로고
    • Ablation of atrial flutter: Use of irrigated tip catheters
    • Oral abstrakt presentation, Nice, France
    • Defaye P, Lagrange P, Mariottini CI et al. Ablation of atrial flutter: Use of irrigated tip catheters. Oral abstrakt presentation, Cardiostim 2002, Nice, France.
    • Cardiostim 2002
    • Defaye, P.1    Lagrange, P.2    Mariottini, C.I.3
  • 14
    • 0034332724 scopus 로고    scopus 로고
    • Comparison of effectiveness of an 8-mm versus 4-mm tip electrode catheter for radiofrequency ablation of typical atrial flutter
    • Kasai A, Anselem F, Teo WS et al. Comparison of effectiveness of an 8-mm versus 4-mm tip electrode catheter for radiofrequency ablation of typical atrial flutter. Am J Cardiol 2000; 86: 1029-1032.
    • (2000) Am J Cardiol , vol.86 , pp. 1029-1032
    • Kasai, A.1    Anselem, F.2    Teo, W.S.3
  • 15
    • 0036692907 scopus 로고    scopus 로고
    • Prospective randomized comparison of cooled radiofrequency versus standard radiofrequency energy for ablation of typical atrial flutter
    • Atiga WL, Worley SJ et al. Prospective randomized comparison of cooled radiofrequency versus standard radiofrequency energy for ablation of typical atrial flutter. PACE 2002; 25: 1172-1178.
    • (2002) PACE , vol.25 , pp. 1172-1178
    • Atiga, W.L.1    Worley, S.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.