-
1
-
-
4544384312
-
Theoretical estimates of the solid angle subtended by a dual diaphragm-detector assembly for alpha sources
-
J.C. Aguiar, and E. Galiano Theoretical estimates of the solid angle subtended by a dual diaphragm-detector assembly for alpha sources Appl. Radiat. Isot. 61 2004 1349 1351
-
(2004)
Appl. Radiat. Isot.
, vol.61
, pp. 1349-1351
-
-
Aguiar, J.C.1
Galiano, E.2
-
2
-
-
20444409080
-
238Pu solution by the defined solid angle method utilizing a novel dual diaphragm-detector assembly
-
238Pu solution by the defined solid angle method utilizing a novel dual diaphragm-detector assembly Appl. Radiat. Isot. 63 2005 229 233
-
(2005)
Appl. Radiat. Isot.
, vol.63
, pp. 229-233
-
-
Aguiar, J.C.1
Galiano, E.2
Arenillas, P.3
-
3
-
-
0014618989
-
A radioactive tracer technique for measuring coolant mixing in nuclear reactor fuel sub-assemblies
-
M. Carelli, G. Curzio, and A. Renieri A radioactive tracer technique for measuring coolant mixing in nuclear reactor fuel sub-assemblies Nucl. Eng. Des. 11 1 1970 93 102
-
(1970)
Nucl. Eng. Des.
, vol.11
, Issue.1
, pp. 93-102
-
-
Carelli, M.1
Curzio, G.2
Renieri, A.3
-
4
-
-
0031194384
-
TM film
-
TM film Appl. Radiat. Isot. 48 7 1997 985 990
-
(1997)
Appl. Radiat. Isot.
, vol.48
, Issue.7
, pp. 985-990
-
-
Cheung, Y.C.1
Yu, P.K.N.2
Young, E.C.M.3
Chan, C.L.4
Ng, M.F.5
Tang, F.N.F.6
Wong, T.P.Y.7
-
5
-
-
38249015566
-
The needs for brachytherapy source calibrations in the United States
-
B.M. Coursey, L.J. Goodman, D.D. Hoppes, R. Loevinger, W.L. McLaughlin, C.G. Soares, and J.T. Weaver The needs for brachytherapy source calibrations in the United States Nucl. Method Instrum. A 312 1-2 1992 246 250
-
(1992)
Nucl. Method Instrum. a
, vol.312
, Issue.1-2
, pp. 246-250
-
-
Coursey, B.M.1
Goodman, L.J.2
Hoppes, D.D.3
Loevinger, R.4
McLaughlin, W.L.5
Soares, C.G.6
Weaver, J.T.7
-
6
-
-
0026648245
-
Radiation safety considerations for post-iodine-131 thyroid cancer therapy
-
C.M. Culver, and H.J. Dworkin Radiation safety considerations for post-iodine-131 thyroid cancer therapy J. Nucl. Med. 33 7 1992 1402 1405
-
(1992)
J. Nucl. Med.
, vol.33
, Issue.7
, pp. 1402-1405
-
-
Culver, C.M.1
Dworkin, H.J.2
-
7
-
-
32044439998
-
A thin parallel plate ionization chamber for calibration of microselectron sources
-
K.R. Das, and M.B. Kenny A thin parallel plate ionization chamber for calibration of microselectron sources Radiother. Oncol. 37 1995 S10
-
(1995)
Radiother. Oncol.
, vol.37
, pp. 10
-
-
Das, K.R.1
Kenny, M.B.2
-
8
-
-
0030760034
-
Monte Carlo calculated dose distribution for endovascular HDR brachytherapy with Ir-192
-
W.J.F. Dries Monte Carlo calculated dose distribution for endovascular HDR brachytherapy with Ir-192 Radiother. Oncol. 45 1 1997 77 82
-
(1997)
Radiother. Oncol.
, vol.45
, Issue.1
, pp. 77-82
-
-
Dries, W.J.F.1
-
9
-
-
10644243680
-
Validation of the nuclear design code system for the HTTR using the criticality assembly VHTRC
-
N. Fujimoto, N. Nojiri, and K. Yamashita Validation of the nuclear design code system for the HTTR using the criticality assembly VHTRC Nucl. Eng. Des. 233 1-3 2004 255 262
-
(2004)
Nucl. Eng. Des.
, vol.233
, Issue.1-3
, pp. 255-262
-
-
Fujimoto, N.1
Nojiri, N.2
Yamashita, K.3
-
10
-
-
32044464682
-
High level radioactive solid waste burial operations for the EBR-II fuel cycle facility
-
W.F. Holcomb, D.M. Paige, C.E. Stevenson, and D.E. Graham High level radioactive solid waste burial operations for the EBR-II fuel cycle facility Nucl. Eng. Des. 5 2 1967 221 227
-
(1967)
Nucl. Eng. Des.
, vol.5
, Issue.2
, pp. 221-227
-
-
Holcomb, W.F.1
Paige, D.M.2
Stevenson, C.E.3
Graham, D.E.4
-
12
-
-
11244266134
-
Potential third-party radiation exposure from outpatients treated with I-131 for hyperthyroidism
-
R. Matheoud, E. Reschini, C. Canzi, F. Voltini, and P. Gerundini Potential third-party radiation exposure from outpatients treated with I-131 for hyperthyroidism Med. Phys. 31 12 2004 3194 3200
-
(2004)
Med. Phys.
, vol.31
, Issue.12
, pp. 3194-3200
-
-
Matheoud, R.1
Reschini, E.2
Canzi, C.3
Voltini, F.4
Gerundini, P.5
-
13
-
-
14544292822
-
Thermoluminescence dosimetry of model line sources containing vanadium-48
-
E. Rorat, B. Petelenz, B. Marczewska, and E. Ochab Thermoluminescence dosimetry of model line sources containing vanadium-48 Radiat. Meas. 39 5 2005 495 501
-
(2005)
Radiat. Meas.
, vol.39
, Issue.5
, pp. 495-501
-
-
Rorat, E.1
Petelenz, B.2
Marczewska, B.3
Ochab, E.4
-
14
-
-
33644931781
-
EPR-based dose measurements with alanine in clinical dosimetry
-
B. Schaeken, and A.Z. Middelheim EPR-based dose measurements with alanine in clinical dosimetry Radioth. Oncol. 37 1995 S30
-
(1995)
Radioth. Oncol.
, vol.37
, pp. 30
-
-
Schaeken, B.1
Middelheim, A.Z.2
-
15
-
-
33644881794
-
Monte Carlo calculations for brachytherapy dosimetry
-
S.M. Seltzer, and C.G. Soares Monte Carlo calculations for brachytherapy dosimetry Radiat. Phys. Chem. 53 3 1998 345
-
(1998)
Radiat. Phys. Chem.
, vol.53
, Issue.3
, pp. 345
-
-
Seltzer, S.M.1
Soares, C.G.2
-
16
-
-
0036733627
-
Calculating the absorbed dose from radioactive patients: The line-source versus point-source model
-
J.A. Siegel, C.S. Marcus, and R.B. Sparks Calculating the absorbed dose from radioactive patients: the line-source versus point-source model J. Nucl. Med. 43 9 2002 1241 1244
-
(2002)
J. Nucl. Med.
, vol.43
, Issue.9
, pp. 1241-1244
-
-
Siegel, J.A.1
Marcus, C.S.2
Sparks, R.B.3
|