메뉴 건너뛰기




Volumn 7, Issue 1, 2006, Pages 20-27

Comparison of transaxial source images and 3-plane, thin-slab maximal intensity projection images for the diagnosis of coronary artery stenosis with using ECG-gated cardiac CT

Author keywords

Computed tomography (CT); Coronary vessels; CT coronary vessels; Diagnostic radiology; Maximum intensity projection; Observer performance; Stenosis or obstruction

Indexed keywords

ADULT; AGED; ANGIOCARDIOGRAPHY; ARTICLE; COMPARATIVE STUDY; COMPUTER ASSISTED DIAGNOSIS; COMPUTER ASSISTED TOMOGRAPHY; CORONARY ARTERY OBSTRUCTION; ELECTROCARDIOGRAPHY; FEMALE; HEART RATE; HUMAN; MALE; METHODOLOGY; MIDDLE AGED; RADIOGRAPHY; RETROSPECTIVE STUDY; ROC CURVE;

EID: 33644884514     PISSN: 12296929     EISSN: 12296929     Source Type: Journal    
DOI: 10.3348/kjr.2006.7.1.20     Document Type: Article
Times cited : (8)

References (21)
  • 1
    • 0037109214 scopus 로고    scopus 로고
    • Noninvasive coronary angiography using computed tomography: Ready to kick it up another notch [editorial]
    • Rumberger JA. Noninvasive coronary angiography using computed tomography: ready to kick it up another notch [editorial]. Circulation 2002;106:2036-2038
    • (2002) Circulation , vol.106 , pp. 2036-2038
    • Rumberger, J.A.1
  • 3
  • 4
    • 0036869547 scopus 로고    scopus 로고
    • Non-invasive coronary angiography with high resolution mutidetector-row computed tomography: Results in 102 patients
    • Kopp AF, Schroeder S, Kuettner A, Baumbach A, Georg C, Ohnesorge B, et al. Non-invasive coronary angiography with high resolution mutidetector-row computed tomography: results in 102 patients. Eur Heart J 2002;23:1714-1725
    • (2002) Eur Heart J , vol.23 , pp. 1714-1725
    • Kopp, A.F.1    Schroeder, S.2    Kuettner, A.3    Baumbach, A.4    Georg, C.5    Ohnesorge, B.6
  • 5
    • 0035191747 scopus 로고    scopus 로고
    • Coronary arteries: Retrospectively ECG-gated multi-detector row CT angiography with selective optimization of the image reconstruction window
    • Kopp AF, Schroeder S, Kuettner A, Heuchmid M, Georg C, Ohnesorge B, et al. Coronary arteries: retrospectively ECG-gated multi-detector row CT angiography with selective optimization of the image reconstruction window. Radiology 2001;221:683-688
    • (2001) Radiology , vol.221 , pp. 683-688
    • Kopp, A.F.1    Schroeder, S.2    Kuettner, A.3    Heuchmid, M.4    Georg, C.5    Ohnesorge, B.6
  • 6
    • 0036210278 scopus 로고    scopus 로고
    • Techniques for the detection of coronary atherosclerosis: Multi-detector row CT coronary angiography
    • Vogl TJ, Adolmaali ND, Diebold T, Engelmann K, Ay M, Dogan S, et al. Techniques for the detection of coronary atherosclerosis: multi-detector row CT coronary angiography. Radiology 2002;223:212-220
    • (2002) Radiology , vol.223 , pp. 212-220
    • Vogl, T.J.1    Adolmaali, N.D.2    Diebold, T.3    Engelmann, K.4    Ay, M.5    Dogan, S.6
  • 7
    • 0242670021 scopus 로고    scopus 로고
    • Image quality in a standardized algorithm for minimally invasive coronary angiography with multislice spiral computed tomography
    • Gerber TC, Kuzo RS, Lane GE, O'Brien PC, Karstaedt N, Morin RL, et al. Image quality in a standardized algorithm for minimally invasive coronary angiography with multislice spiral computed tomography. J Comput Assist Tomogr 2003;27:62-69
    • (2003) J Comput Assist Tomogr , vol.27 , pp. 62-69
    • Gerber, T.C.1    Kuzo, R.S.2    Lane, G.E.3    O'Brien, P.C.4    Karstaedt, N.5    Morin, R.L.6
  • 8
    • 0037950406 scopus 로고    scopus 로고
    • Value of 3D-volume rendering in the assessment of coronary arteries with retrospectively ECG-gated multislice spiral CT
    • Mahnken AH, Wildberger JE, Sinha AM, Dedden K, Stanzel S, Hoffmann R, et al. Value of 3D-volume rendering in the assessment of coronary arteries with retrospectively ECG-gated multislice spiral CT. Acta Radiol 2003;44:302-309
    • (2003) Acta Radiol , vol.44 , pp. 302-309
    • Mahnken, A.H.1    Wildberger, J.E.2    Sinha, A.M.3    Dedden, K.4    Stanzel, S.5    Hoffmann, R.6
  • 10
    • 0035186294 scopus 로고    scopus 로고
    • Maximum stenosis of extracranial internal carotid artery: Effect of luminal morphology on stenosis measurement by using CT angiography and conventional DSA
    • Hirai T, Korogi Y, Ono K, Murata Y, Takahashi M, Suginohara K, et al. Maximum stenosis of extracranial internal carotid artery: effect of luminal morphology on stenosis measurement by using CT angiography and conventional DSA. Radiology 2001;221:802-807
    • (2001) Radiology , vol.221 , pp. 802-807
    • Hirai, T.1    Korogi, Y.2    Ono, K.3    Murata, Y.4    Takahashi, M.5    Suginohara, K.6
  • 11
    • 0028157491 scopus 로고
    • Spiral CT of renal artery stenosis: Comparison of three-dimensional rendering techniques
    • Rubin G, Dake MD, Napel S, Jeffrey RB, McDonnell CH, Sommer FG, et al. Spiral CT of renal artery stenosis: comparison of three-dimensional rendering techniques. Radiology 1994;190:181-189
    • (1994) Radiology , vol.190 , pp. 181-189
    • Rubin, G.1    Dake, M.D.2    Napel, S.3    Jeffrey, R.B.4    McDonnell, C.H.5    Sommer, F.G.6
  • 12
    • 0031714267 scopus 로고    scopus 로고
    • Assessment of renal artery stenosis with CT angiography: Usefulness of multiplanar reformation, quantitative stenosis measurement, and densitometric analysis of renal parenchymal enhancement as adjuncts to MIP film rendering
    • Berg MH, Manninen HI, Vanninen RL, Vainio RA, Soimakallio S. Assessment of renal artery stenosis with CT angiography: usefulness of multiplanar reformation, quantitative stenosis measurement, and densitometric analysis of renal parenchymal enhancement as adjuncts to MIP film rendering. J Comput Assist Tomogr 1998;22:533-540
    • (1998) J Comput Assist Tomogr , vol.22 , pp. 533-540
    • Berg, M.H.1    Manninen, H.I.2    Vanninen, R.L.3    Vainio, R.A.4    Soimakallio, S.5
  • 13
    • 0029334523 scopus 로고
    • Three-dimensional spiral CT during arterial portography: Comparison of three rendering techniques
    • Heath DG, Soyer PA, Kuszyk BS, Bliss DF, Calhoun PS, Bluemke DA, et al. Three-dimensional spiral CT during arterial portography: comparison of three rendering techniques. Radio Graphics 1995;15:1001-1011
    • (1995) Radio Graphics , vol.15 , pp. 1001-1011
    • Heath, D.G.1    Soyer, P.A.2    Kuszyk, B.S.3    Bliss, D.F.4    Calhoun, P.S.5    Bluemke, D.A.6
  • 14
    • 0034883727 scopus 로고    scopus 로고
    • Effects of window and threshold levels on the accuracy of three-dimensional rendering techniques in coronary artery electron-beam CT angiography
    • Lu Bin, Dai RP, Jiang SL, Bai H, He S, Zhuang N, et al. Effects of window and threshold levels on the accuracy of three-dimensional rendering techniques in coronary artery electron-beam CT angiography. Acad Radiol 2001;8:754-761
    • (2001) Acad Radiol , vol.8 , pp. 754-761
    • Bin, L.1    Dai, R.P.2    Jiang, S.L.3    Bai, H.4    He, S.5    Zhuang, N.6
  • 16
    • 3142537670 scopus 로고    scopus 로고
    • Coronary artery imaging with multidetector CT: Visualization issues
    • Aug.
    • Peter MA, van Ooijen P, Ho KY, Dorgelo J, Oudkerk M. Coronary artery imaging with multidetector CT: visualization issues. RadioGraphics 2003 Aug. Available from: URL: http://radiographics.rsnajnls.org/cgi/content/full/e16v1
    • (2003) RadioGraphics
    • Peter, M.A.1    Van Ooijen, P.2    Ho, K.Y.3    Dorgelo, J.4    Oudkerk, M.5
  • 17
    • 0348047573 scopus 로고    scopus 로고
    • Current concepts in multi-detector row CT evaluation of the coronary arteries: Principles, techniques, and anatomy
    • Pannu HK, Flohr TG, Corl FM, Fishman EK. Current concepts in multi-detector row CT evaluation of the coronary arteries: principles, techniques, and anatomy. RadioGraphics 2003;23:s111-125
    • (2003) RadioGraphics , vol.23
    • Pannu, H.K.1    Flohr, T.G.2    Corl, F.M.3    Fishman, E.K.4
  • 18
    • 0345004081 scopus 로고    scopus 로고
    • Diagnostic performance of helical CT angiography in trauma to large arteries of the extremities
    • Soto JA, Munera F, Cardoso N, Guarin O, Medina S. Diagnostic performance of helical CT angiography in trauma to large arteries of the extremities. J Comput Assist Tomogr 1999;23:188-196
    • (1999) J Comput Assist Tomogr , vol.23 , pp. 188-196
    • Soto, J.A.1    Munera, F.2    Cardoso, N.3    Guarin, O.4    Medina, S.5
  • 19
    • 0031844317 scopus 로고    scopus 로고
    • CT angiography in vascular intervention for steno-occlusive diseases: Role of multiplanar reconstruction and source images
    • Sugahara T, Korogi Y, Hirai T, Hamatake S, Komohara Y, Okuda T, et al. CT angiography in vascular intervention for steno-occlusive diseases: role of multiplanar reconstruction and source images. Br J Radiol 1998;71:601-611
    • (1998) Br J Radiol , vol.71 , pp. 601-611
    • Sugahara, T.1    Korogi, Y.2    Hirai, T.3    Hamatake, S.4    Komohara, Y.5    Okuda, T.6
  • 20
    • 0037380226 scopus 로고    scopus 로고
    • Diagnostic value of maximum intensity projections versus source images for assessment of contrast-enhanced three-dimensional breath-hold magnetic resonance coronary angiography
    • Regenfus M, Ropers D, Achenback S, Schlundt C, Kessler W, Laub G, et al. Diagnostic value of maximum intensity projections versus source images for assessment of contrast-enhanced three-dimensional breath-hold magnetic resonance coronary angiography. Invest Radiol 2003;38:200-206
    • (2003) Invest Radiol , vol.38 , pp. 200-206
    • Regenfus, M.1    Ropers, D.2    Achenback, S.3    Schlundt, C.4    Kessler, W.5    Laub, G.6
  • 21
    • 0035024416 scopus 로고    scopus 로고
    • CT data storage reduction by means of compressing projection data instead of images: Feasibility study
    • Bae KT, Whiting BR. CT data storage reduction by means of compressing projection data instead of images: feasibility study. Radiology 2003;219:850-855
    • (2003) Radiology , vol.219 , pp. 850-855
    • Bae, K.T.1    Whiting, B.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.