메뉴 건너뛰기




Volumn 26, Issue 8-9, 2005, Pages 295-301

Ultrasonic dissector for total thyroidectomy: Results of prospective randomized study;Tiroidectomia totale con impiego del dissettore ad ultrasuoni: Risultati di uno studio prospettico randomizzato

Author keywords

Goiter; Thyroidectomy; Ultrasonic dissector

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; FEMALE; HUMAN; MALE; METHODOLOGY; MIDDLE AGED; PROSPECTIVE STUDY; RANDOMIZED CONTROLLED TRIAL; THYROIDECTOMY; ULTRASOUND THERAPY;

EID: 33644875417     PISSN: 03919005     EISSN: 1971145X     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (8)

References (19)
  • 1
    • 0034097614 scopus 로고    scopus 로고
    • Ultrasonically activated shears in thyroidectomies: A randomized trial
    • Voutilainen PE, Haglund, CH. Ultrasonically activated shears in thyroidectomies: a randomized trial. Ann Surg 2000; 231(3):322-328.
    • (2000) Ann Surg , vol.231 , Issue.3 , pp. 322-328
    • Voutilainen, P.E.1    Haglund, C.H.2
  • 2
    • 85013019332 scopus 로고
    • UltraCision® Inc. harmonic scalpel operating manual
    • Smithfield RI. UltraCision® Inc. harmonic scalpel operating manual, 1995.
    • (1995)
    • Smithfield, R.I.1
  • 4
    • 0023240248 scopus 로고
    • Surgical hypothyroidism
    • Di Gesù G. Surgical hypothyroidism. Min Med 1987; 78(8):519-27.
    • (1987) Min Med , vol.78 , Issue.8 , pp. 519-527
    • Di Gesù, G.1
  • 6
    • 0023226818 scopus 로고
    • Hypocalcemia after thyroidectomy. Pathogenic and clinical aspects
    • Di Gesù G. Hypocalcemia after thyroidectomy. Pathogenic and clinical aspects. Min Med 1987; 78(6):393-8.
    • (1987) Min Med , vol.78 , Issue.6 , pp. 393-398
    • Di Gesù, G.1
  • 7
    • 0036518719 scopus 로고    scopus 로고
    • Role of color flow doppler sonography in pre operative diagnostics of the thyroid pathology
    • Giammanco M, Di Gesù G, Massenti MF, Di Trapani B, Vetri G. Role of color flow doppler sonography in pre operative diagnostics of the thyroid pathology. Min Endocrinol 2002; (1):10.
    • (2002) Min Endocrinol , vol.1 , pp. 10
    • Giammanco, M.1    Di Gesù, G.2    Massenti, M.F.3    Di Trapani, B.4    Vetri, G.5
  • 8
    • 0038618930 scopus 로고    scopus 로고
    • Ultrasonic scalpel in thyroid surgery
    • Marchesi M et al. Ultrasonic scalpel in thyroid surgery. Chir Ital 2003; 55(2): 299-308.
    • (2003) Chir Ital , vol.55 , Issue.2 , pp. 299-308
    • Marchesi, M.1
  • 9
    • 0029781889 scopus 로고    scopus 로고
    • Physiologic mechanism of the ultrasonically activated scalpel
    • McCarus SD. Physiologic mechanism of the ultrasonically activated scalpel. J Am Gynecol Laparosc 1996; 3:601-608.
    • (1996) J am Gynecol Laparosc , vol.3 , pp. 601-608
    • McCarus, S.D.1
  • 10
    • 0036160006 scopus 로고    scopus 로고
    • The use of the Harmonic Scalpel vs conventional knot tying for vessel ligation in thyroid sugery
    • Siperstein AE, Berber E, Morkoyun E. The use of the Harmonic Scalpel vs conventional knot tying for vessel ligation in thyroid sugery. Arch Surg 2002; 137:137-141.
    • (2002) Arch Surg , vol.137 , pp. 137-141
    • Siperstein, A.E.1    Berber, E.2    Morkoyun, E.3
  • 11
    • 0029076225 scopus 로고
    • Laparoscopic cholecistectomy in 200 consecutive patients using an ultrasonically activated scalpel
    • Amaral JF. Laparoscopic cholecistectomy in 200 consecutive patients using an ultrasonically activated scalpel. Surg Laparosc Endosc 1995; 5:255-262.
    • (1995) Surg Laparosc Endosc , vol.5 , pp. 255-262
    • Amaral, J.F.1
  • 12
    • 0028213002 scopus 로고
    • The experimental development of an ultrasonically activated scalpel for laparoscopic use
    • Amaral JF. The experimental development of an ultrasonically activated scalpel for laparoscopic use. Surg Laparosc Endosc 1994; 4:92-99.
    • (1994) Surg Laparosc Endosc , vol.4 , pp. 92-99
    • Amaral, J.F.1
  • 14
    • 3042611944 scopus 로고    scopus 로고
    • Prospective study of postoperative complications after total thyroidectomy for multinodular goiters by surgeons with experience in endocrine surgery
    • Zambudio A R, Rodriguez J, Riquelme J, Soria T, Canteras M, Parrilla P. Prospective study of postoperative complications after total thyroidectomy for multinodular goiters by surgeons with experience in endocrine surgery. Ann Surg 2004; 240(1):18-25.
    • (2004) Ann Surg , vol.240 , Issue.1 , pp. 18-25
    • Zambudio, A.R.1    Rodriguez, J.2    Riquelme, J.3    Soria, T.4    Canteras, M.5    Parrilla, P.6
  • 15
    • 0033407589 scopus 로고    scopus 로고
    • Ultrasonically actived scalpel for subtotal thyroidectomy in Grave's disease
    • Takami H, Ikeda I, Niimi M. Ultrasonically actived scalpel for subtotal thyroidectomy in Grave's disease. Am J Surg 1999; 178:433.
    • (1999) Am J Surg , vol.178 , pp. 433
    • Takami, H.1    Ikeda, I.2    Niimi, M.3
  • 16
    • 0036781220 scopus 로고    scopus 로고
    • Thyroidectomy using the harmonic scalpel: Analysis of 105 consecutives cases. Otolaryngol
    • Shemen L. Thyroidectomy using the harmonic scalpel: analysis of 105 consecutives cases. Otolaryngol. Head Neck Surg 2002; 127:284-288.
    • (2002) Head Neck Surg , vol.127 , pp. 284-288
    • Shemen, L.1
  • 17
    • 0036877665 scopus 로고    scopus 로고
    • The harmonic scalpel and surgery of the thyroid gland
    • Vach B, Fanta J, Velenska Z. The harmonic scalpel and surgery of the thyroid gland. Rozhl Chir 2002; Suppl 1:S3-7.
    • (2002) Rozhl Chir , pp. S3-S7
    • Vach, B.1    Fanta, J.2    Velenska, Z.3
  • 18
    • 1442359035 scopus 로고    scopus 로고
    • Efficacy and cost-effectiveness of the Ultracision® harmonic scalpel in thyroid surgery: An analysis of 200 cases in a randomized trial
    • Ortega MD, Sala MD, Flor MD, Lledo MD: Efficacy and cost-effectiveness of the Ultracision® harmonic scalpel in thyroid surgery: an analysis of 200 cases in a randomized trial. J Laparosc Endosc Advanced Surg Tech 2004; 14:9-12.
    • (2004) J Laparosc Endosc Advanced Surg Tech , vol.14 , pp. 9-12
    • Ortega, M.D.1    Sala, M.D.2    Flor, M.D.3    Lledo, M.D.4
  • 19
    • 0033920503 scopus 로고    scopus 로고
    • Évaluation de l'utilisation du dissecteur ultrasonic UltraCision® en chirurgie thyroidienne
    • Meurisse M, Defechereux T, Maweja S, Degauque C, Vandelaer M, Hamoir E. Évaluation de l'utilisation du dissecteur ultrasonic UltraCision® en chirurgie thyroidienne. Ann Chir 2000; 125:468-472.
    • (2000) Ann Chir , vol.125 , pp. 468-472
    • Meurisse, M.1    Defechereux, T.2    Maweja, S.3    Degauque, C.4    Vandelaer, M.5    Hamoir, E.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.