메뉴 건너뛰기




Volumn 17, Issue 12, 2005, Pages

Snare retrieval of the distal tip of a fractured rotational atherectomy guidewire: Roping the steer by its horns

Author keywords

[No Author keywords available]

Indexed keywords

HIRULOG;

EID: 33644875069     PISSN: 10423931     EISSN: 15572501     Source Type: Journal    
DOI: None     Document Type: Short Survey
Times cited : (16)

References (26)
  • 1
    • 0023624609 scopus 로고
    • Retained percutaneous transluminal coronary angioplasty equipment components and their management
    • Hartzler GO, Rutherford BD, McConahay DR. Retained percutaneous transluminal coronary angioplasty equipment components and their management. Am J Cardiol 1987;60:1260-1264.
    • (1987) Am J Cardiol , vol.60 , pp. 1260-1264
    • Hartzler, G.O.1    Rutherford, B.D.2    McConahay, D.R.3
  • 2
    • 0022902951 scopus 로고
    • Sucsessful percutaneous removal of retained broken coronary angioplasty guidewire
    • Krone RJ. Sucsessful percutaneous removal of retained broken coronary angioplasty guidewire. Cathet Cardiovasc Diagn 1986;12:409-410.
    • (1986) Cathet Cardiovasc Diagn , vol.12 , pp. 409-410
    • Krone, R.J.1
  • 3
    • 0026022617 scopus 로고
    • Percutaneous extraction of fractured guidewire from distal right coronary artery
    • Savas V, Schreiber T, O'Neill W. Percutaneous extraction of fractured guidewire from distal right coronary artery. Cathet Cardiovasc Diagn 1991;22:124-126.
    • (1991) Cathet Cardiovasc Diagn , vol.22 , pp. 124-126
    • Savas, V.1    Schreiber, T.2    O'Neill, W.3
  • 4
    • 0028458291 scopus 로고
    • The fracture, dislodgement and retrieval of a probe III balloon-on-a-wire catheter
    • Hwang MH, Hsieh AA, Silverman P, Loeb HS. The fracture, dislodgement and retrieval of a probe III balloon-on-a-wire catheter. J Invasive Cardiol 1994;6:154-156.
    • (1994) J Invasive Cardiol , vol.6 , pp. 154-156
    • Hwang, M.H.1    Hsieh, A.A.2    Silverman, P.3    Loeb, H.S.4
  • 5
    • 0023758492 scopus 로고
    • Transcatheter retrieval of intracoronary detached angioplasty guidewire segment
    • Mikolich JR, Hanson MW. Transcatheter retrieval of intracoronary detached angioplasty guidewire segment. Cathet Cardiovasc Diagn 1988;15:44-46.
    • (1988) Cathet Cardiovasc Diagn , vol.15 , pp. 44-46
    • Mikolich, J.R.1    Hanson, M.W.2
  • 6
    • 0024402512 scopus 로고
    • Improved method for transcatheter retrieval of intracoronary detached angioplasty guidewire segments
    • Serota H, Deligonul U, Lew B, et al. Improved method for transcatheter retrieval of intracoronary detached angioplasty guidewire segments. Cathet Cardiovasc Diagn 1989;17:248-251.
    • (1989) Cathet Cardiovasc Diagn , vol.17 , pp. 248-251
    • Serota, H.1    Deligonul, U.2    Lew, B.3
  • 7
    • 0032128537 scopus 로고    scopus 로고
    • Percutaneous retrieval of transsected rotablator coronary guidewire using amplatz "goose-neck snare"
    • Pande AK, Doucet S. Percutaneous retrieval of transsected rotablator coronary guidewire using amplatz "goose-neck snare". Indian Heart J 1998;50:439-442.
    • (1998) Indian Heart J , vol.50 , pp. 439-442
    • Pande, A.K.1    Doucet, S.2
  • 8
    • 0025005180 scopus 로고
    • An alternative method for transcatheter retrieval of intracoronary angioplasty equipment fragments
    • Mintz GS, Bemis CE, Unwala AA, et al. An alternative method for transcatheter retrieval of intracoronary angioplasty equipment fragments. Cathet Cardiovasc Diagn 1990;20:247-250.
    • (1990) Cathet Cardiovasc Diagn , vol.20 , pp. 247-250
    • Mintz, G.S.1    Bemis, C.E.2    Unwala, A.A.3
  • 9
    • 0029016755 scopus 로고
    • Guidewire transection during rotational coronary atherectomy due to guide catheter dislodgement and wire kinking
    • Foster-Smith K, Garratt KN, Holmes DR. Guidewire transection during rotational coronary atherectomy due to guide catheter dislodgement and wire kinking. Cathet Cardiovasc Diagn 1995;35:224-227.
    • (1995) Cathet Cardiovasc Diagn , vol.35 , pp. 224-227
    • Foster-Smith, K.1    Garratt, K.N.2    Holmes, D.R.3
  • 10
    • 0025310036 scopus 로고
    • Removal of retained intracoronary percutaneous transluminal coronary angioplasty equipment by a percutaneous twin guidewire method
    • Gurley JC, Booth DC, Hixson C, Smith MD. Removal of retained intracoronary percutaneous transluminal coronary angioplasty equipment by a percutaneous twin guidewire method. Cathet Cardiovasc Diagn 1990;19:251-256.
    • (1990) Cathet Cardiovasc Diagn , vol.19 , pp. 251-256
    • Gurley, J.C.1    Booth, D.C.2    Hixson, C.3    Smith, M.D.4
  • 11
    • 0025232450 scopus 로고
    • Successful percutaneous removal of retained probe balloon wire during coronary angioplasty
    • Yeon EB, Cemaletin NS, Moses JW, McCrossan J. Successful percutaneous removal of retained probe balloon wire during coronary angioplasty. Am Heart J 1990;119:1201-1205.
    • (1990) Am Heart J , vol.119 , pp. 1201-1205
    • Yeon, E.B.1    Cemaletin, N.S.2    Moses, J.W.3    McCrossan, J.4
  • 12
    • 0033672581 scopus 로고    scopus 로고
    • Broken guidewire fragment: A simplified retrieval technique
    • Patel T, Shah S, Pandya R, et al. Broken guidewire fragment: A simplified retrieval technique. Catheter Cardiovasc Interv 2000;51:483-486.
    • (2000) Catheter Cardiovasc Interv , vol.51 , pp. 483-486
    • Patel, T.1    Shah, S.2    Pandya, R.3
  • 13
    • 0025323753 scopus 로고
    • Retrieval of a fractured USCI Probe tip from a diseased coronary artery using another fixed-wire balloon catheter, the Cordis Orion
    • Feldman RL, Trice WA, Hennemann WW, Furst A. Retrieval of a fractured USCI Probe tip from a diseased coronary artery using another fixed-wire balloon catheter, the Cordis Orion. Cathet Cardiovasc Diagn 1990;19:257-263.
    • (1990) Cathet Cardiovasc Diagn , vol.19 , pp. 257-263
    • Feldman, R.L.1    Trice, W.A.2    Hennemann, W.W.3    Furst, A.4
  • 14
    • 0022895245 scopus 로고
    • Fracture and dislodgement of floppy guidewire during percutaneous transluminal coronary angioplasty
    • Khonsari S, Livermore J, Mahrer P, Magnusson P. Fracture and dislodgement of floppy guidewire during percutaneous transluminal coronary angioplasty. Am J Cardiol 1986;58:855-856.
    • (1986) Am J Cardiol , vol.58 , pp. 855-856
    • Khonsari, S.1    Livermore, J.2    Mahrer, P.3    Magnusson, P.4
  • 16
    • 0024551482 scopus 로고
    • Rupture of guide during percutaneous transluminal coronary angioplasty
    • Ghosh PK, Alber G, Schistek R, Unger F. Rupture of guide during percutaneous transluminal coronary angioplasty. J Thorac Cardiovasc Surg 1989;97:467-469.
    • (1989) J Thorac Cardiovasc Surg , vol.97 , pp. 467-469
    • Ghosh, P.K.1    Alber, G.2    Schistek, R.3    Unger, F.4
  • 17
    • 0024721413 scopus 로고
    • Fratura e retencao intracoronariana de catheter guia de angioplastia transluminal percutanea. Relato de caso
    • Dias AR, Garcia DP, Arie S, et al. Fratura e retencao intracoronariana de catheter guia de angioplastia transluminal percutanea. Relato de caso. Arq Bras Cardiol 1989;53:165-166.
    • (1989) Arq Bras Cardiol , vol.53 , pp. 165-166
    • Dias, A.R.1    Garcia, D.P.2    Arie, S.3
  • 18
    • 0023949112 scopus 로고
    • Surgical removal of the intracoronary portion of a fractured angioplasty guidewire
    • Bachenheimer LC, Green CE, Rosing DR, Wallace RB. Surgical removal of the intracoronary portion of a fractured angioplasty guidewire. Am J Cardiol 1988;61:946-947.
    • (1988) Am J Cardiol , vol.61 , pp. 946-947
    • Bachenheimer, L.C.1    Green, C.E.2    Rosing, D.R.3    Wallace, R.B.4
  • 19
    • 0024566021 scopus 로고
    • Entrapment of broken guidewire in the left main coronary artery during percutaneous transluminal coronary angioplasty
    • Sethi GK, Ferguson TB, Miller G, Scott SM. Entrapment of broken guidewire in the left main coronary artery during percutaneous transluminal coronary angioplasty. Ann Thorac Surg 1989;47:455-457.
    • (1989) Ann Thorac Surg , vol.47 , pp. 455-457
    • Sethi, G.K.1    Ferguson, T.B.2    Miller, G.3    Scott, S.M.4
  • 20
    • 0023412693 scopus 로고
    • Guide wire entrapment during PTCA: A potentially dangerous complication
    • Lotan C, Hasin Y, Stone D, et al. Guide wire entrapment during PTCA: A potentially dangerous complication. Cathet Cardiovasc Diagn 1987;13:309-312.
    • (1987) Cathet Cardiovasc Diagn , vol.13 , pp. 309-312
    • Lotan, C.1    Hasin, Y.2    Stone, D.3
  • 21
    • 0023778257 scopus 로고
    • An unusual case of guide wire fracture during percutaneous transluminal coronary angioplasty
    • Vrolix M, Vanhaecke J, Piessens J, Geest HD. An unusual case of guide wire fracture during percutaneous transluminal coronary angioplasty. Cathet Cardiovasc Diagn 1988;15:99-102.
    • (1988) Cathet Cardiovasc Diagn , vol.15 , pp. 99-102
    • Vrolix, M.1    Vanhaecke, J.2    Piessens, J.3    Geest, H.D.4
  • 22
    • 0027199103 scopus 로고
    • Detailed angiographic analysis of high-speed mechanical rotational atherectomy in human coronary arteries
    • Safian RD, Niazi KA, Strzelecki M, et al. Detailed angiographic analysis of high-speed mechanical rotational atherectomy in human coronary arteries. Circulation 1193;88:3:961-968.
    • (1193) Circulation , vol.88 , Issue.3 , pp. 961-968
    • Safian, R.D.1    Niazi, K.A.2    Strzelecki, M.3
  • 23
    • 0031830803 scopus 로고    scopus 로고
    • Fracture of coronary guidewire during rotational atherectomy with coronary perforation and tamponade
    • Woodfield SL, Lopez A, Heuser RR. Fracture of coronary guidewire during rotational atherectomy with coronary perforation and tamponade. Cathet Cardiovasc Diagn 1998;44:220-223.
    • (1998) Cathet Cardiovasc Diagn , vol.44 , pp. 220-223
    • Woodfield, S.L.1    Lopez, A.2    Heuser, R.R.3
  • 24
    • 0022347184 scopus 로고
    • Intravascular retrieval of broken guide wire from the ascending aorta after percutaneous transluminal coronary angioplasty
    • Steele PM, Holmes DR, Mankin HT, Schaff HV. Intravascular retrieval of broken guide wire from the ascending aorta after percutaneous transluminal coronary angioplasty. Cathet Cardiovasc Diagn 1985;11:623-628.
    • (1985) Cathet Cardiovasc Diagn , vol.11 , pp. 623-628
    • Steele, P.M.1    Holmes, D.R.2    Mankin, H.T.3    Schaff, H.V.4
  • 25
    • 0023112927 scopus 로고
    • Snare loop technique for removal of broken steerable PTCA wire
    • Watson LE. Snare loop technique for removal of broken steerable PTCA wire. Cathet Cardiovasc Diagn 1987;13:44-49.
    • (1987) Cathet Cardiovasc Diagn , vol.13 , pp. 44-49
    • Watson, L.E.1
  • 26
    • 0036155828 scopus 로고    scopus 로고
    • Mobilization and retrieval of an entrapped guidewire in the right coronary artery
    • Reith S, Volk O, Klues HG. Mobilization and retrieval of an entrapped guidewire in the right coronary artery. Z Kardiol 2002;91:58-61.
    • (2002) Z Kardiol , vol.91 , pp. 58-61
    • Reith, S.1    Volk, O.2    Klues, H.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.