메뉴 건너뛰기




Volumn 26, Issue 6, 2005, Pages 24-32

Motion analysis system: The techniques and principles, the protocols, the sources of errors and solutions;Les systèmes d'analyse du mouvement: Techniques et principes, protocoles, sources d'erreurs et solutions

Author keywords

[No Author keywords available]

Indexed keywords

BIOMEDICAL TECHNOLOGY ASSESSMENT; EVALUATION; EXPERIMENTATION; FRANCE; HEALTH CARE ORGANIZATION; HEALTH CARE PLANNING; HEALTH CARE POLICY; INSTRUMENTATION; METHODOLOGY; MOTION ANALYSIS SYSTEM; PRACTICE GUIDELINE; REVIEW; TECHNIQUE; TECHNOLOGY;

EID: 33644868463     PISSN: 12979570     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1297-9570(05)80046-9     Document Type: Article
Times cited : (6)

References (32)
  • 1
    • 0002308563 scopus 로고
    • Direct linear transformation from comparator coordinates into object space coordinates in close-range photogrammetry
    • Falls Church, Va.
    • Abdel-Aziz YI, Karara HM. Direct linear transformation from comparator coordinates into object space coordinates in close-range photogrammetry. ASP Symposium on close-range photogrammetry 1971, Falls Church, Va.
    • (1971) ASP Symposium on Close-range Photogrammetry
    • Abdel-Aziz, Y.I.1    Karara, H.M.2
  • 2
    • 0002748083 scopus 로고
    • Bases of three dimensional reconstruction
    • Allard P. Stokes I.A.F. Blanchi J.P.
    • Allard P, Blanchi JP, and Aissaoui R Bases of three dimensional reconstruction Allard P Stokes IAF Blanchi JP 3D Analysis of Human Movement 1995 19 40
    • (1995) 3D Analysis of Human Movement , pp. 19-40
    • Allard, P.1    Blanchi, J.P.2    Aissaoui, R.3
  • 3
    • 0020078249 scopus 로고
    • Three-dimensional cinematography with control object of unknown shape
    • Dapena Three-dimensional cinematography with control object of unknown shape J. Biomechanics 15 1982 11 19
    • (1982) J. Biomechanics , vol.15 , pp. 11-19
    • Dapena1
  • 4
    • 0032192530 scopus 로고    scopus 로고
    • Complete calibration of a stereophotogrammetric system through control points of unknown coordinates
    • Cerveri P, Borghese NA, and Pedotti A Complete calibration of a stereophotogrammetric system through control points of unknown coordinates J Biomech 31 10 1998 935 940
    • (1998) J Biomech , vol.31 , Issue.10 , pp. 935-940
    • Cerveri, P.1    Borghese, N.A.2    Pedotti, A.3
  • 5
    • 0035147559 scopus 로고    scopus 로고
    • A fast method for calibrating video-based motion analysers using only a rigid bar
    • Borghese NA, Cerveri P, and Rigiroli R A fast method for calibrating video-based motion analysers using only a rigid bar Med Biol Eng Comput 39 1 2001 935 940
    • (2001) Med Biol Eng Comput , vol.39 , Issue.1 , pp. 935-940
    • Borghese, N.A.1    Cerveri, P.2    Rigiroli, R.3
  • 6
    • 0029311073 scopus 로고
    • A position and orientation of bones during the movement: Anatomical frame definition and determination?
    • Cappozzo A A position and orientation of bones during the movement: anatomical frame definition and determination? Clin Biomech 10 4 1995 171 178
    • (1995) Clin Biomech , vol.10 , Issue.4 , pp. 171-178
    • Cappozzo, A.1
  • 7
    • 0030111274 scopus 로고    scopus 로고
    • Position and orientation of bones during movement: Experimental artefacts
    • Cappozzo A Position and orientation of bones during movement: experimental artefacts Clin Biomech 11 2 1996 90 100
    • (1996) Clin Biomech , vol.11 , Issue.2 , pp. 90-100
    • Cappozzo, A.1
  • 8
    • 0033980146 scopus 로고    scopus 로고
    • Comparison of surface mounted markers and attachment methods in estimating tibial rotations during walking: An in vivo study
    • Manal K Comparison of surface mounted markers and attachment methods in estimating tibial rotations during walking: an in vivo study Gait Posture 11 2000 38 45
    • (2000) Gait Posture , vol.11 , pp. 38-45
    • Manal, K.1
  • 9
    • 19644389189 scopus 로고    scopus 로고
    • Human movement analysis using stereophotogrammetry. Part 2: Instrumental errors
    • Chiari L, Della Croce U, Leardini A, and Cappozzo A Human movement analysis using stereophotogrammetry. Part 2: Instrumental errors Gait Posture 21 2005 197 211
    • (2005) Gait Posture , vol.21 , pp. 197-211
    • Chiari, L.1    Della Croce, U.2    Leardini, A.3    Cappozzo, A.4
  • 10
    • 0029114425 scopus 로고
    • ISB recommendations for standardization in the reporting of cinematic data
    • Wu G, and Cavanagh PR ISB recommendations for standardization in the reporting of cinematic data Journal of Biomechanics 28 1995 1257 1261
    • (1995) Journal of Biomechanics , vol.28 , pp. 1257-1261
    • Wu, G.1    Cavanagh, P.R.2
  • 11
    • 0036207866 scopus 로고    scopus 로고
    • ISB recommendation on definitions of joint coordinate system of various joint for the reporting of human joint motion - Ankle, hip, and spine
    • Wu G, Siegler S, Allard P, and Kirtley C ISB recommendation on definitions of joint coordinate system of various joint for the reporting of human joint motion - ankle, hip, and spine Journal of Biomechanics 35 2002 543 548
    • (2002) Journal of Biomechanics , vol.35 , pp. 543-548
    • Wu, G.1    Siegler, S.2    Allard, P.3    Kirtley, C.4
  • 13
    • 0034120591 scopus 로고    scopus 로고
    • A spot-chek for estimating stereophotogrammetric errors
    • Della Croce U, and Cappozzo A A spot-chek for estimating stereophotogrammetric errors Med Biol Eng Comput 38 2000 260 266
    • (2000) Med Biol Eng Comput , vol.38 , pp. 260-266
    • Della Croce, U.1    Cappozzo, A.2
  • 14
    • 0002351047 scopus 로고
    • Opteolectronic-based systems
    • Allard P. Stokes I.A.F. Blanchi J.P. Human kinetics Champaign, IL
    • Pedotti A, and Ferrigno G Opteolectronic-based systems Allard P Stokes IAF Blanchi JP Three-dimensional analysis of human movement 1995 Human kinetics Champaign, IL 57 77
    • (1995) Three-dimensional Analysis of Human Movement , pp. 57-77
    • Pedotti, A.1    Ferrigno, G.2
  • 15
    • 0024163868 scopus 로고    scopus 로고
    • Precision evaluations of digital imagery for close-range photogrammetric applications
    • Shortis MR Precision evaluations of digital imagery for close-range photogrammetric applications Photogramm Eng Rem S 54 1998 1395 1401
    • (1998) Photogramm Eng Rem S , vol.54 , pp. 1395-1401
    • Shortis, M.R.1
  • 16
    • 0035056894 scopus 로고    scopus 로고
    • A new calibration method for 3D position measurement in biomedical applications
    • Schmid OA A new calibration method for 3D position measurement in biomedical applications Biomed Technik 46 2001 50 54
    • (2001) Biomed Technik , vol.46 , pp. 50-54
    • Schmid, O.A.1
  • 17
    • 33644870676 scopus 로고
    • Stereometric system accuracy tests
    • Measurement and Data processing methodology in clinical movement analysis-preliminary
    • Cappozzo A Stereometric system accuracy tests Measurement and Data processing methodology in clinical movement analysis-preliminary Camarc II internal Report 1993
    • (1993) Camarc II Internal Report
    • Cappozzo, A.1
  • 18
    • 2042459216 scopus 로고
    • An investigation of the sources and characteristics of noise in a video-based kinematic measurement system
    • Models, connections with experimental apparatus and relevant DSP techniques for functional movement analysis
    • Morris JRW, and MacLeod A An investigation of the sources and characteristics of noise in a video-based kinematic measurement system Models, connections with experimental apparatus and relevant DSP techniques for functional movement analysis Camarc II Internal Report 1990
    • (1990) Camarc II Internal Report
    • Morris, J.R.W.1    MacLeod, A.2
  • 19
    • 0000732709 scopus 로고
    • Comparison of the performances of 3D camera systems
    • Ehara Y Comparison of the performances of 3D camera systems Gait Posture 3 1995 166 169
    • (1995) Gait Posture , vol.3 , pp. 166-169
    • Ehara, Y.1
  • 20
    • 0030764482 scopus 로고    scopus 로고
    • Comparison of the performances of 3D camera systems
    • Ehara Y Comparison of the performances of 3D camera systems Gait Posture 5 1997 251 255
    • (1997) Gait Posture , vol.5 , pp. 251-255
    • Ehara, Y.1
  • 21
    • 0038626649 scopus 로고    scopus 로고
    • A proposed test to support the clinical movement analysis laboratory acceditation process
    • Holden JP A proposed test to support the clinical movement analysis laboratory acceditation process Gait Posture 17 2003 205 213
    • (2003) Gait Posture , vol.17 , pp. 205-213
    • Holden, J.P.1
  • 22
    • 0032871313 scopus 로고    scopus 로고
    • Measuring small linear displacements with a three dimensional video motion analysis system: Determining its accuracy and precision
    • Everaert DG Measuring small linear displacements with a three dimensional video motion analysis system: determining its accuracy and precision Arch Phys Med Rehabil 80 9 1999 1082 1089
    • (1999) Arch Phys Med Rehabil , vol.80 , Issue.9 , pp. 1082-1089
    • Everaert, D.G.1
  • 23
    • 0001746929 scopus 로고    scopus 로고
    • The measurement of human motion: A comparison of commercially available systems
    • Richards JG The measurement of human motion: a comparison of commercially available systems Hum Mov Sci 18 1999 589 602
    • (1999) Hum Mov Sci , vol.18 , pp. 589-602
    • Richards, J.G.1
  • 24
    • 21644483092 scopus 로고    scopus 로고
    • Assessment of the kinematic variability between twelves Shiners motion analysis laboratories
    • April 25th-28th Sacramento, California.
    • Gorton G, Herbert D, Goode B. Assessment of the kinematic variability between twelves Shiners motion analysis laboratories. VIth Annual Gait and Clinical Movement Analysis meeting, April 25th-28th 2001, Sacramento, California.
    • (2001) VIth Annual Gait and Clinical Movement Analysis Meeting
    • Gorton, G.1    Herbert, D.2    Goode, B.3
  • 25
    • 33644865745 scopus 로고    scopus 로고
    • Présentation des systèmes d'analyse de la marche. la marche humaine, la course et le saut
    • Viel E. Masson
    • Laassel EM Présentation des systèmes d'analyse de la marche. La marche humaine, la course et le saut Viel E Biomécanique, exploration, normes et dysfonctionnements 2000 Masson 113 136
    • (2000) Biomécanique, Exploration, Normes et Dysfonctionnements , pp. 113-136
    • Laassel, E.M.1
  • 26
    • 0020098329 scopus 로고
    • A linear approach to the analysis of rigid body displacement from initial and final position data
    • Laub AJ, and Shiflett GR A linear approach to the analysis of rigid body displacement from initial and final position data J Appl Mech 49 1982 213 216
    • (1982) J Appl Mech , vol.49 , pp. 213-216
    • Laub, A.J.1    Shiflett, G.R.2
  • 27
    • 0018841551 scopus 로고
    • Rigid body motion calculated from spatial coordinates of markers
    • Spoor CW, and Veldpaus FE Rigid body motion calculated from spatial coordinates of markers J Biomech 13 1980 391 393
    • (1980) J Biomech , vol.13 , pp. 391-393
    • Spoor, C.W.1    Veldpaus, F.E.2
  • 28
    • 0023819125 scopus 로고
    • A least square algorithm for the equiform transformation from spaital marker coordinates
    • Veldpaus FE, Woltring HJ, and Dortmans LJMG A least square algorithm for the equiform transformation from spaital marker coordinates J Biomech 21 1988 45 54
    • (1988) J Biomech , vol.21 , pp. 45-54
    • Veldpaus, F.E.1    Woltring, H.J.2    Ljmg, D.3
  • 30
    • 0027897660 scopus 로고
    • Determining the movements of the skeleton using well-configured markers
    • Soderkvist I, and Weedin PA Determining the movements of the skeleton using well-configured markers J Biomech 26 1993 1473 1477
    • (1993) J Biomech , vol.26 , pp. 1473-1477
    • Soderkvist, I.1    Weedin, P.A.2
  • 31
    • 0029329169 scopus 로고
    • A solidification procedure to facilitate cinematic analysis based on video system data
    • Chèze L, Fregly BJ, and Dimnet J A solidification procedure to facilitate cinematic analysis based on video system data Journal of Biomechanics 28 1995 879 884
    • (1995) Journal of Biomechanics , vol.28 , pp. 879-884
    • Chèze, L.1    Fregly, B.J.2    Dimnet, J.3
  • 32
    • 0033081306 scopus 로고    scopus 로고
    • Bone position estimation from skin maker coordinates using global optimisation with joint constraints
    • Lu TW, and O'Connor JJ Bone position estimation from skin maker coordinates using global optimisation with joint constraints Journal of Biomechanics 32 1999 129 134
    • (1999) Journal of Biomechanics , vol.32 , pp. 129-134
    • Lu, T.W.1    O'Connor, J.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.