메뉴 건너뛰기




Volumn 77, Issue 6, 2005, Pages 351-356

Composite prostheses for the repair of abdominal wall defects: Comparative study of physical and/or chemical barriers;Prótesis compuestas en las reparaciones de defectos de pared abdominal. Estudio comparativo del empleo de barreras físicas y/o químicas

Author keywords

Abdominal wall; Adhesions; Biomaterials; Composite prostheses

Indexed keywords

ABDOMINAL WALL HERNIA; ANIMAL; ARTICLE; COMPARATIVE STUDY; MALE; RABBIT; SURGICAL EQUIPMENT;

EID: 33644866864     PISSN: 0009739X     EISSN: 1578147X     Source Type: Journal    
DOI: 10.1016/S0009-739X(05)70869-1     Document Type: Article
Times cited : (8)

References (21)
  • 1
    • 0141595034 scopus 로고    scopus 로고
    • Cost analysis of incisional hernia repair by suture or mesh
    • Israelsson LA, Jönsson L, Wimo A. Cost analysis of incisional hernia repair by suture or mesh. Hernia. 2003;7:114-7.
    • (2003) Hernia , vol.7 , pp. 114-117
    • Israelsson, L.A.1    Jönsson, L.2    Wimo, A.3
  • 2
    • 0030175524 scopus 로고    scopus 로고
    • Interface formed between visceral peritoneum and experimental polypropylene or polytetraflurotethylene abdominal wall implants
    • Bellón JM, Buján J, Contreras L, Hernando A. Interface formed between visceral peritoneum and experimental polypropylene or polytetraflurotethylene abdominal wall implants. J Mat Sci Mat Med. 1996;7:331-6.
    • (1996) J Mat Sci Mat Med , vol.7 , pp. 331-336
    • Bellón, J.M.1    Buján, J.2    Contreras, L.3    Hernando, A.4
  • 3
    • 0030038758 scopus 로고    scopus 로고
    • Comparison of a new type of polytetrafluoroethylene patch (Mycro-Mesh) and polypropylene prosthesis (Marlex) for repair of abdominal wall defects
    • Bellón JM, Buján J, Contreras L, Carrera-San Martin A, Jurado F. Comparison of a new type of polytetrafluoroethylene patch (Mycro-Mesh) and polypropylene prosthesis (Marlex) for repair of abdominal wall defects. J Am Coll Surg. 1996;183:11-8.
    • (1996) J Am Coll Surg , vol.183 , pp. 11-18
    • Bellón, J.M.1    Buján, J.2    Contreras, L.3    Carrera-San Martin, A.4    Jurado, F.5
  • 4
    • 0033997191 scopus 로고    scopus 로고
    • Small bowel obstruction resulting from mesh plug migration after open inguinal hernia repair
    • Chuback JA, Sigh RS, Sill C, Dick LS. Small bowel obstruction resulting from mesh plug migration after open inguinal hernia repair. Surgery. 2000;127:475-6.
    • (2000) Surgery , vol.127 , pp. 475-476
    • Chuback, J.A.1    Sigh, R.S.2    Sill, C.3    Dick, L.S.4
  • 5
    • 0036343075 scopus 로고    scopus 로고
    • The structure of a biomaterial rather than its chemical composition modulates the repair process at the peritoneal level
    • Bellón JM, Jurado F, García-Honduvilla N, López R, Carrera-San Martín A, Buján J. The structure of a biomaterial rather than its chemical composition modulates the repair process at the peritoneal level. Am J Surg. 2002;184:154-9.
    • (2002) Am J Surg , vol.184 , pp. 154-159
    • Bellón, J.M.1    Jurado, F.2    García-Honduvilla, N.3    López, R.4    Carrera-San Martín, A.5    Buján, J.6
  • 6
    • 0030199858 scopus 로고    scopus 로고
    • Effect of phosphatidylchlilne on the process of peritoneal adhesion following implantation of a polypropylene mesh prosthesis
    • Bellón JM, Contreras L, Buján J, Jurado F. Effect of phosphatidylchlilne on the process of peritoneal adhesion following implantation of a polypropylene mesh prosthesis. Biomaterials. 1996;17:1369-72.
    • (1996) Biomaterials , vol.17 , pp. 1369-1372
    • Bellón, J.M.1    Contreras, L.2    Buján, J.3    Jurado, F.4
  • 7
    • 0029986108 scopus 로고    scopus 로고
    • Effect of rat mesenchymal stem cell on development of abdominal adhesions after surgery
    • Lucas PA, Warejka DJ, Zhang LM, Newuman WH, Young HE. Effect of rat mesenchymal stem cell on development of abdominal adhesions after surgery. J Surg Res. 1996;62:229-32.
    • (1996) J Surg Res , vol.62 , pp. 229-232
    • Lucas, P.A.1    Warejka, D.J.2    Zhang, L.M.3    Newuman, W.H.4    Young, H.E.5
  • 8
    • 0029067330 scopus 로고
    • The abdominal compartment syndrome: The physiological and clinical consequences of elevated intra-abdominal pressure
    • Schein M, Wittmann DH, Aprahamian CC, Condon RE. The abdominal compartment syndrome: The physiological and clinical consequences of elevated intra-abdominal pressure. J Am Coll Surg. 1995;180:745-53.
    • (1995) J Am Coll Surg , vol.180 , pp. 745-753
    • Schein, M.1    Wittmann, D.H.2    Aprahamian, C.C.3    Condon, R.E.4
  • 9
    • 0020545865 scopus 로고
    • A comparison of prosthetic materials used to repair abdominal wall defects
    • Jenkins SD, Klamer TW, Parteka JJ, Condon RE. A comparison of prosthetic materials used to repair abdominal wall defects. Surgery. 1983;94:392-7.
    • (1983) Surgery , vol.94 , pp. 392-397
    • Jenkins, S.D.1    Klamer, T.W.2    Parteka, J.J.3    Condon, R.E.4
  • 10
    • 0027299720 scopus 로고
    • Reduction of postoperative adhesions to Marlex mesh using experimental adhesion barriers in rats
    • Naim JO, Pulley D, Scanlan K, Hinshaw JR, Lanzafame RJ. Reduction of postoperative adhesions to Marlex mesh using experimental adhesion barriers in rats. J Laparoendosc Surg. 1993;3:187-90.
    • (1993) J Laparoendosc Surg , vol.3 , pp. 187-190
    • Naim, J.O.1    Pulley, D.2    Scanlan, K.3    Hinshaw, J.R.4    Lanzafame, R.J.5
  • 12
    • 0032918309 scopus 로고    scopus 로고
    • Prevention of adhesions to polypropylne mesh in a rabbit model
    • Dinsmore RC, Calton WC. Prevention of adhesions to polypropylne mesh in a rabbit model. Am Surg. 1999;65:383-7.
    • (1999) Am Surg , vol.65 , pp. 383-387
    • Dinsmore, R.C.1    Calton, W.C.2
  • 13
    • 0342647529 scopus 로고    scopus 로고
    • Seprafilm reduces adhesions to polypropylene mesh
    • Baptista ML, Bonsack ME, Delaney JP. Seprafilm reduces adhesions to polypropylene mesh. Surgery. 2000;128:86-92.
    • (2000) Surgery , vol.128 , pp. 86-92
    • Baptista, M.L.1    Bonsack, M.E.2    Delaney, J.P.3
  • 14
    • 0034021449 scopus 로고    scopus 로고
    • Evaluation of Seprafilm and amniotic membrane as adhesion prohylaxis in mesh repair of abdominal wall hernia in rats
    • Szabo A, Haj M, Waxman I, Eitan A. Evaluation of Seprafilm and amniotic membrane as adhesion prohylaxis in mesh repair of abdominal wall hernia in rats. Eur Surg Res. 2000;32:125-8.
    • (2000) Eur Surg Res , vol.32 , pp. 125-128
    • Szabo, A.1    Haj, M.2    Waxman, I.3    Eitan, A.4
  • 15
    • 0027483834 scopus 로고
    • Double-layer prostheses for repair of abdominal wall defects in a rabbit model
    • Walker AP, Henderson J, Condon RE. Double-layer prostheses for repair of abdominal wall defects in a rabbit model. J Surg Res. 1993;55:27-32.
    • (1993) J Surg Res , vol.55 , pp. 27-32
    • Walker, A.P.1    Henderson, J.2    Condon, R.E.3
  • 16
    • 0028391888 scopus 로고
    • Experimental evaluation of a new composite mesh with the selective property of incorporation to the abdominal wall without adhering to the intestines
    • Amid PK, Shulman AG, Lichtenstein IL, Sostrin S, Young J, Hakakha M. Experimental evaluation of a new composite mesh with the selective property of incorporation to the abdominal wall without adhering to the intestines. J Biomed Mat Res. 1994;28:373-5.
    • (1994) J Biomed Mat Res , vol.28 , pp. 373-375
    • Amid, P.K.1    Shulman, A.G.2    Lichtenstein, I.L.3    Sostrin, S.4    Young, J.5    Hakakha, M.6
  • 19
    • 0034942223 scopus 로고    scopus 로고
    • Prothèse pariétale composite et non résorbable en polyéthylène téréphtalate-polyuréthane (HI-TEX PARP NT): prévention des adhérences intrapéritonéales Etude expérimentale chez le lapin
    • Sodji M, Rogier R, Durand-Fontanier S, Lachachi F, Cheynel N, Lombin L, et al. Prothèse pariétale composite et non résorbable en polyéthylène téréphtalate-polyuréthane (HI-TEX PARP NT): prévention des adhérences intrapéritonéales. Etude expérimentale chez le lapin. Ann Chir. 2001;126:549-53.
    • (2001) Ann Chir , vol.126 , pp. 549-553
    • Sodji, M.1    Rogier, R.2    Durand-Fontanier, S.3    Lachachi, F.4    Cheynel, N.5    Lombin, L.6
  • 20
    • 0036615405 scopus 로고    scopus 로고
    • Evaluation of a new composite prostheses (PL-PU 99) for the repair of abdominal wall defects in terms of behavior at the peritoneal interface
    • Bellón JM, García-Carranza A, Jurado F, García-Honduvilla N, Carrera-San Martín A, et al. Evaluation of a new composite prostheses (PL-PU 99) for the repair of abdominal wall defects in terms of behavior at the peritoneal interface.World J Surg. 2002;26:661-6.
    • (2002) World J Surg , vol.26 , pp. 661-666
    • Bellón, J.M.1    García-Carranza, A.2    Jurado, F.3    García-Honduvilla, N.4    Carrera-San Martín, A.5
  • 21
    • 0027739578 scopus 로고
    • Le traitement des éventrations post-opératoires par prothèse composée (polyester-polyglactine 910) Etude clinique et expérimentale
    • Soler M, Verhaeghe P, Essomba A, Sevestre H, Stoppa R. Le traitement des éventrations post-opératoires par prothèse composée (polyester-polyglactine 910). Etude clinique et expérimentale. Ann Chir. 1993;47:598-608.
    • (1993) Ann Chir , vol.47 , pp. 598-608
    • Soler, M.1    Verhaeghe, P.2    Essomba, A.3    Sevestre, H.4    Stoppa, R.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.