메뉴 건너뛰기




Volumn 22, Issue 1, 2006, Pages 47-53

In vivo variability in quantitative coronary ultrasound and tissue characterization measurements with mechanical and phased-array catheters

Author keywords

Atherosclerosis; Imaging; Plaque characterization; Ultrasonography

Indexed keywords

ADULT; AGED; ARTICLE; ATHEROSCLEROTIC PLAQUE; CALCULATION; CLINICAL ARTICLE; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; CORONARY BLOOD VESSEL; ECHOCARDIOGRAPHY; FEMALE; HEART CATHETERIZATION; HUMAN; IN VIVO STUDY; INTRAVASCULAR ULTRASOUND; MALE; MORPHOMETRICS; PROSPECTIVE STUDY; QUANTITATIVE ANALYSIS; TISSUE CHARACTERIZATION; ULTRASOUND TRANSDUCER;

EID: 33644858452     PISSN: 15695794     EISSN: 18758312     Source Type: Journal    
DOI: 10.1007/s10554-005-6423-1     Document Type: Article
Times cited : (18)

References (21)
  • 1
    • 0025352353 scopus 로고
    • Intravascular ultrasound imaging: In vitro validation and pathologic correlation
    • RA Nishimura, WD Edwards and CA Warnes, Intravascular ultrasound imaging: In vitro validation and pathologic correlation. J Am Coll Cardiol 16 (1990) 145-154
    • (1990) J Am Coll Cardiol , vol.16 , pp. 145-154
    • Nishimura, R.A.1    Edwards, W.D.2    Warnes, C.A.3
  • 2
    • 0032147104 scopus 로고    scopus 로고
    • Intravascular ultrasound-guided optimized stent deployment. Immediate and 6 months clinical and angiographic results from the Multicenter Ultrasound Stenting in Coronaries Study (MUSIC Study)
    • P Jaegere de, H Mudra and H Figulla, Intravascular ultrasound-guided optimized stent deployment. Immediate and 6 months clinical and angiographic results from the Multicenter Ultrasound Stenting in Coronaries Study (MUSIC Study). Eur Heart J 19 (1998) 1214-1223
    • (1998) Eur Heart J , vol.19 , pp. 1214-1223
    • de Jaegere, P.1    Mudra, H.2    Figulla, H.3
  • 3
    • 0034255377 scopus 로고    scopus 로고
    • Final results of the Can Routine Ultrasound Influence Stent Expansion (CRUISE) study
    • PJ Fitzgerald, A Oshima and M Hayase, Final results of the Can Routine Ultrasound Influence Stent Expansion (CRUISE) study. Circulation 102 (2000) 523-530
    • (2000) Circulation , vol.102 , pp. 523-530
    • Fitzgerald, P.J.1    Oshima, A.2    Hayase, M.3
  • 4
    • 0028964399 scopus 로고
    • Intracoronary ultrasound-defined plaque composition: Computer-aided plaque characterization and correlation with histologic samples obtained during directional coronary atherectomy
    • Q Rasheed, PJ Dhawale, J Anderson and JM Hodgson, Intracoronary ultrasound-defined plaque composition: Computer-aided plaque characterization and correlation with histologic samples obtained during directional coronary atherectomy. Am Heart J 129 (1995) 631-637
    • (1995) Am Heart J , vol.129 , pp. 631-637
    • Rasheed, Q.1    Dhawale, P.J.2    Anderson, J.3    Hodgson, J.M.4
  • 5
    • 0037159282 scopus 로고    scopus 로고
    • Coronary plaque classification with intravascular ultrasound radiofrequency data analysis
    • A Nair, BD Kuban, EM Tuzcu, P Schoenhagen, SE Nissen and DG Vince, Coronary plaque classification with intravascular ultrasound radiofrequency data analysis. Circulation 106 (2002) 2200-2206
    • (2002) Circulation , vol.106 , pp. 2200-2206
    • Nair, A.1    Kuban, B.D.2    Tuzcu, E.M.3    Schoenhagen, P.4    Nissen, S.E.5    Vince, D.G.6
  • 6
    • 0035943069 scopus 로고    scopus 로고
    • Use of intravascular ultrasound to compare effects of different strategies of lipid-lowering therapy on plaque volume and composition in patients with coronary artery disease
    • M Schartl, W Bocksch and DH Koschyk, Use of intravascular ultrasound to compare effects of different strategies of lipid-lowering therapy on plaque volume and composition in patients with coronary artery disease. Circulation 104 (2001) 387-392
    • (2001) Circulation , vol.104 , pp. 387-392
    • Schartl, M.1    Bocksch, W.2    Koschyk, D.H.3
  • 7
    • 0030485531 scopus 로고    scopus 로고
    • Variability of a three-layered appearance in intravascular ultrasound coronary images: A comparison of morphometric measurements with four intravascular ultrasound systems
    • T Hiro, CY Leung, RJ Russo, H Karimi, AR Farvid and JM Tobis, Variability of a three-layered appearance in intravascular ultrasound coronary images: A comparison of morphometric measurements with four intravascular ultrasound systems. Am J Card Imaging 10 (1996) 219-227
    • (1996) Am J Card Imaging , vol.10 , pp. 219-227
    • Hiro, T.1    Leung, C.Y.2    Russo, R.J.3    Karimi, H.4    Farvid, A.R.5    Tobis, J.M.6
  • 8
    • 0030485690 scopus 로고    scopus 로고
    • Variability in tissue characterization of atherosclerotic plaque by intravascular ultrasound: A comparison of four intravascular ultrasound systems
    • T Hiro, CY Leung and RJ Russo, Variability in tissue characterization of atherosclerotic plaque by intravascular ultrasound: A comparison of four intravascular ultrasound systems. Am J Card Imaging 10 (1996) 209-218
    • (1996) Am J Card Imaging , vol.10 , pp. 209-218
    • Hiro, T.1    Leung, C.Y.2    Russo, R.J.3
  • 9
    • 2942722484 scopus 로고    scopus 로고
    • Variability in quantitative measurement of the same segment with two different intravascular ultrasound systems: In vivo and in vitro studies
    • Y Li, J Honye and S Saito, Variability in quantitative measurement of the same segment with two different intravascular ultrasound systems: In vivo and in vitro studies. Catheter Cardiovasc Interv 62 (2004) 175-180
    • (2004) Catheter Cardiovasc Interv , vol.62 , pp. 175-180
    • Li, Y.1    Honye, J.2    Saito, S.3
  • 10
    • 0035970098 scopus 로고    scopus 로고
    • Intravascular ultrasound: Novel pathophysiological insights and current clinical applications
    • SE Nissen and P Yock, Intravascular ultrasound: Novel pathophysiological insights and current clinical applications. Circulation 103 (2001) 604-616
    • (2001) Circulation , vol.103 , pp. 604-616
    • Nissen, S.E.1    Yock, P.2
  • 11
    • 0034768314 scopus 로고    scopus 로고
    • Correlation between high frequency intravascular ultrasound and histomorphology in human coronary arteries
    • F Prati, E Arbustini and A Labellarte, Correlation between high frequency intravascular ultrasound and histomorphology in human coronary arteries. Heart 85 (2001) 567-570
    • (2001) Heart , vol.85 , pp. 567-570
    • Prati, F.1    Arbustini, E.2    Labellarte, A.3
  • 12
    • 0036238827 scopus 로고    scopus 로고
    • Atherosclerotic plaque characterization by quantitative analysis using intravascular ultrasound: Correlation with histological and immunohistochemical findings
    • T Okimoto, M Imazu, Y Hayashi, H Fujiwara, H Ueda and N Kohno, Atherosclerotic plaque characterization by quantitative analysis using intravascular ultrasound: Correlation with histological and immunohistochemical findings. Circ J 66 (2002) 173-177
    • (2002) Circ J , vol.66 , pp. 173-177
    • Okimoto, T.1    Imazu, M.2    Hayashi, Y.3    Fujiwara, H.4    Ueda, H.5    Kohno, N.6
  • 13
    • 4143098364 scopus 로고    scopus 로고
    • Computer assisted three-dimensional plaque characterization in ultracoronary ultrasound studies
    • SA Winter de, I Heller and R Hamers, Computer assisted three-dimensional plaque characterization in ultracoronary ultrasound studies. Computers in Cardiology 30 (2003) 73-76
    • (2003) Computers in Cardiology , vol.30 , pp. 73-76
    • de Winter, S.A.1    Heller, I.2    Hamers, R.3
  • 14
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • JM Bland and DG Altman, Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1 (1986) 307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 15
    • 0242577955 scopus 로고    scopus 로고
    • Effect of recombinant ApoA-I Milano on coronary atherosclerosis in patients with acute coronary syndromes: A randomized controlled trial
    • SE Nissen, T Tsunoda and EM Tuzcu, Effect of recombinant ApoA-I Milano on coronary atherosclerosis in patients with acute coronary syndromes: A randomized controlled trial. Jama 290 (2003) 2292-2300
    • (2003) Jama , vol.290 , pp. 2292-2300
    • Nissen, S.E.1    Tsunoda, T.2    Tuzcu, E.M.3
  • 16
    • 10744225301 scopus 로고    scopus 로고
    • Effect of intensive compared with moderate lipid-lowering therapy on progression of coronary atherosclerosis: A randomized controlled trial
    • SE Nissen, EM Tuzcu and P Schoenhagen, Effect of intensive compared with moderate lipid-lowering therapy on progression of coronary atherosclerosis: A randomized controlled trial. Jama 291 (2004) 1071-1080
    • (2004) Jama , vol.291 , pp. 1071-1080
    • Nissen, S.E.1    Tuzcu, E.M.2    Schoenhagen, P.3
  • 17
    • 3242740941 scopus 로고    scopus 로고
    • Regression of coronary atherosclerosis by simvastatin: A serial intravascular ultrasound study
    • LO Jensen, P Thayssen, KE Pedersen, S Stender and T Haghfelt, Regression of coronary atherosclerosis by simvastatin: A serial intravascular ultrasound study. Circulation 110 (2004) 265-270
    • (2004) Circulation , vol.110 , pp. 265-270
    • Jensen, L.O.1    Thayssen, P.2    Pedersen, K.E.3    Stender, S.4    Haghfelt, T.5
  • 18
    • 0347926134 scopus 로고    scopus 로고
    • Variability of area measurements obtained with different intravascular ultrasound catheter systems: Impact on clinical trials and a method for accurate calibration
    • P Schoenhagen, SK Sapp and EM Tuzcu, Variability of area measurements obtained with different intravascular ultrasound catheter systems: Impact on clinical trials and a method for accurate calibration. J Am Soc Echocardiogr 16 (2003) 277-284
    • (2003) J Am Soc Echocardiogr , vol.16 , pp. 277-284
    • Schoenhagen, P.1    Sapp, S.K.2    Tuzcu, E.M.3
  • 19
    • 0034534203 scopus 로고    scopus 로고
    • Reliability of mechanical and phased-array designs for serial intravascular ultrasound examinations - Animal and clinical studies in stented and non-stented coronary arteries
    • JC Tardif, OF Bertrand and R Mongrain, Reliability of mechanical and phased-array designs for serial intravascular ultrasound examinations - animal and clinical studies in stented and non-stented coronary arteries. Int J Card Imaging 16 (2000) 365-375
    • (2000) Int J Card Imaging , vol.16 , pp. 365-375
    • Tardif, J.C.1    Bertrand, O.F.2    Mongrain, R.3
  • 20
    • 0028051850 scopus 로고
    • Intracoronary ultrasound imaging: Intraobserver and interobserver variability of morphometric measurements
    • D Hausmann, AJ Lundkvist, GJ Friedrich, WL Mullen, PJ Fitzgerald and PG Yock, Intracoronary ultrasound imaging: Intraobserver and interobserver variability of morphometric measurements. Am Heart J 128 (1994) 674-680
    • (1994) Am Heart J , vol.128 , pp. 674-680
    • Hausmann, D.1    Lundkvist, A.J.2    Friedrich, G.J.3    Mullen, W.L.4    Fitzgerald, P.J.5    Yock, P.G.6
  • 21
    • 11144354325 scopus 로고    scopus 로고
    • Spectrum of remodeling behavior observed with serial long-term (≥12 months) follow-up intravascular ultrasound studies in left main coronary arteries
    • C Birgelen Von, M Hartmann and GS Mintz, Spectrum of remodeling behavior observed with serial long-term (≥12 months) follow-up intravascular ultrasound studies in left main coronary arteries. Am J Cardiol 93 (2004) 1107-1113
    • (2004) Am J Cardiol , vol.93 , pp. 1107-1113
    • Von Birgelen, C.1    Hartmann, M.2    Mintz, G.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.