메뉴 건너뛰기




Volumn 75, Issue 10, 2005, Pages 866-868

Use of two-point discrimination as a nerve repair assessment tool: Preliminary report

Author keywords

Nerve regeneration; Neurosurgical procedures; Outcome assessment; Peripheral nerves; Reproducibility

Indexed keywords

ARTICLE; NERVE REGENERATION; NEUROSURGERY; PERIPHERAL NERVE; REPRODUCIBILITY; STATISTICAL ANALYSIS; TACTILE DISCRIMINATION; COMPARATIVE STUDY; EVALUATION; HUMAN; INSTRUMENTATION; MEDICAL EDUCATION; METHODOLOGY; NEUROLOGIC EXAMINATION; NURSE; OBSERVER VARIATION; ORTHOPEDICS; TOUCH; TREATMENT OUTCOME;

EID: 33644822100     PISSN: 14451433     EISSN: 14452197     Source Type: Journal    
DOI: 10.1111/j.1445-2197.2005.03557.x     Document Type: Article
Times cited : (27)

References (12)
  • 3
    • 0042472821 scopus 로고    scopus 로고
    • A new model instrument for outcome after nerve repair
    • Rosen B, Lundborg G. A new model instrument for outcome after nerve repair. Hand Clin. 2003; 19: 463 70.
    • (2003) Hand Clin. , vol.19 , pp. 463-70
    • Rosen, B.1    Lundborg, G.2
  • 4
    • 0000540405 scopus 로고
    • The unsolved problem: How to test the functional value of hand sensibility
    • Moberg E. The unsolved problem: how to test the functional value of hand sensibility. J. Hand Ther. 1991 4: 105 10.
    • (1991) J. Hand Ther. , vol.4 , pp. 105-10
    • Moberg, E.1
  • 5
    • 0034192983 scopus 로고    scopus 로고
    • A model instrument for the documentation of outcome after nerve repair
    • Rosen B, Lundborg G. A model instrument for the documentation of outcome after nerve repair. J. Hand Surg. 2000 3: 535 453.
    • (2000) J. Hand Surg. , vol.3 , pp. 535-453
    • Rosen, B.1    Lundborg, G.2
  • 6
    • 0023405675 scopus 로고
    • Reliability of two-point discrimination measurements
    • Dellon AL, Mackinnon SE, Crosby PM. Reliability of two-point discrimination measurements. J. Hand Surg. 1987 5: 693 6.
    • (1987) J. Hand Surg. , vol.5 , pp. 693-6
    • Dellon, A.L.1    MacKinnon, S.E.2    Crosby, P.M.3
  • 7
    • 0030664529 scopus 로고    scopus 로고
    • The force-time relationship of clinically used sensory testing instruments
    • Bell-Krotoski JA, Buford WL. The force-time relationship of clinically used sensory testing instruments. J. Hand Ther. 1997 10: 297 309.
    • (1997) J. Hand Ther. , vol.10 , pp. 297-309
    • Bell-Krotoski, J.A.1    Buford, W.L.2
  • 8
    • 0031765986 scopus 로고    scopus 로고
    • A new tactile gnosis instrument in sensibility testing
    • Rosen B, Lundborg G. A new tactile gnosis instrument in sensibility testing. J. Hand Ther. 1998 11: 251 7.
    • (1998) J. Hand Ther. , vol.11 , pp. 251-7
    • Rosen, B.1    Lundborg, G.2
  • 9
    • 0029024848 scopus 로고
    • Sollerman hand function test: A standardized method and its use in tetraplegic patients
    • Sollerman C, Ejeskar A. Sollerman hand function test: a standardized method and its use in tetraplegic patients. Scand. J. Plast. Reconstr. Surg. Hand Surg. 1995 29: 167 76.
    • (1995) Scand. J. Plast. Reconstr. Surg. Hand Surg. , vol.29 , pp. 167-76
    • Sollerman, C.1    Ejeskar, A.2
  • 11
    • 0026736059 scopus 로고
    • Human pressure perception values for constant and moving one- and two-point discrimination
    • Dellon ES, Mourey R, Dellon AL. Human pressure perception values for constant and moving one- and two-point discrimination. Plast. Reconstr. Surg. 1992 90: 112 17.
    • (1992) Plast. Reconstr. Surg. , vol.90 , pp. 112-17
    • Dellon, E.S.1    Mourey, R.2    Dellon, A.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.