메뉴 건너뛰기




Volumn 50, Issue 11, 2005, Pages 355-360

Retransfusion of unwashed drainage blood after total hip and knee arthroplasty;Retransfusion ungewaschenen drainageblutes nach hüft- und knieendoprothesenimplantationen

Author keywords

Drainage blood; Hip arthroplasty; Knee arthroplasty; Retransfusion

Indexed keywords

BIOMEDICAL ENGINEERING; COSTS; HIP PROSTHESES; PATIENT TREATMENT;

EID: 33644808455     PISSN: 00135585     EISSN: None     Source Type: Journal    
DOI: 10.1515/BMT.2005.050     Document Type: Article
Times cited : (2)

References (20)
  • 1
    • 0031784218 scopus 로고    scopus 로고
    • Red blood cell retransfusion practices in patients undergoing orthopedic surgery: A multiinstitutional analysis
    • Audet AM, Andrzejewski C, Popovsky MA. Red blood cell retransfusion practices in patients undergoing orthopedic surgery: a multiinstitutional analysis. Orthopedics 1998; 21: 851-858.
    • (1998) Orthopedics , vol.21 , pp. 851-858
    • Audet, A.M.1    Andrzejewski, C.2    Popovsky, M.A.3
  • 5
    • 0034896780 scopus 로고    scopus 로고
    • Tourniquet use during total knee arthroplasty did not reduce total blood loss
    • Iorio R, Healy WL. Tourniquet use during total knee arthroplasty did not reduce total blood loss. J. bone Joint Surg. Am. 2001; 83: 1282.
    • (2001) J. Bone Joint Surg. Am. , vol.83 , pp. 1282
    • Iorio, R.1    Healy, W.L.2
  • 6
    • 0034791791 scopus 로고    scopus 로고
    • Does temporary clambing of drains following knee arthroplasty reduce blood loss? A randomised controlled trial
    • Kiely N, Hockings M, Gambhir A. Does temporary clambing of drains following knee arthroplasty reduce blood loss? A randomised controlled trial. Knee 2001; 8: 325-327.
    • (2001) Knee , vol.8 , pp. 325-327
    • Kiely, N.1    Hockings, M.2    Gambhir, A.3
  • 7
    • 0031894483 scopus 로고    scopus 로고
    • Blood transfusion strategies for total knee arthroplasty: Minimizing autologous blood wastage, risk of homologous blood transfusion, and transfusion cost
    • Knight JL, Sherer D, Guo J. Blood transfusion strategies for total knee arthroplasty: minimizing autologous blood wastage, risk of homologous blood transfusion, and transfusion cost. J. Arthroplasty 1998; 13: 70-76.
    • (1998) J. Arthroplasty , vol.13 , pp. 70-76
    • Knight, J.L.1    Sherer, D.2    Guo, J.3
  • 8
    • 0032702621 scopus 로고    scopus 로고
    • The use of fibrin tissue adhesive to reduce blood loss and the need for blood transfusion after total knee artrhoplasty. A prospektive, randomized, multicenter study
    • Levy O, Martinowitz U, Oran A, Tauber C, Horoszowski H. The use of fibrin tissue adhesive to reduce blood loss and the need for blood transfusion after total knee artrhoplasty. A prospektive, randomized, multicenter study. J. Bone Joint Surg. Am. 1999; 81: 1580-1588.
    • (1999) J. Bone Joint Surg. Am. , vol.81 , pp. 1580-1588
    • Levy, O.1    Martinowitz, U.2    Oran, A.3    Tauber, C.4    Horoszowski, H.5
  • 10
    • 0030727274 scopus 로고    scopus 로고
    • Strategies to reduce the need for peri-operative blood transfusion
    • Mertes N, Booke M, Van Aken H. Strategies to reduce the need for peri-operative blood transfusion. Eur. J. Anaesthesiol. Suppl. 1997; 14: 24-34.
    • (1997) Eur. J. Anaesthesiol. Suppl. , vol.14 , pp. 24-34
    • Mertes, N.1    Booke, M.2    Van Aken, H.3
  • 12
    • 0034786884 scopus 로고    scopus 로고
    • Re-transfusion of autologous blood from wound drains: The means for reducing transfusion requirements in total knee arthroplasty
    • Peter VK, Radford M, Metthews MG. Re-Transfusion of autologous blood from wound drains: the means for reducing transfusion requirements in total knee arthroplasty. Knee 2002; 8: 321-323.
    • (2002) Knee , vol.8 , pp. 321-323
    • Peter, V.K.1    Radford, M.2    Metthews, M.G.3
  • 14
    • 0032926208 scopus 로고    scopus 로고
    • Blood managemant experience: Relationship between autologous blood donation and transfusion in orthpedic surgery
    • Sculco TP, Gallina J. Blood managemant experience: relationship between autologous blood donation and transfusion in orthpedic surgery. Orthopedics 1999; 22: 129-134.
    • (1999) Orthopedics , vol.22 , pp. 129-134
    • Sculco, T.P.1    Gallina, J.2
  • 15
    • 0030694037 scopus 로고    scopus 로고
    • Blood loss during primary total hip arthroplasty; use of preoperative measurements to predict the need of transfusion
    • Walker RW, Rosson JR, Bland JM. Blood loss during primary total hip arthroplasty; use of preoperative measurements to predict the need of transfusion. Ann. R. Coll. Surg. Engl. 1997; 79: 438-440.
    • (1997) Ann. R. Coll. Surg. Engl. , vol.79 , pp. 438-440
    • Walker, R.W.1    Rosson, J.R.2    Bland, J.M.3
  • 16
    • 0035522621 scopus 로고    scopus 로고
    • The use of the orthopedic perioperative autotransfusion (OrthoPAT) system in total joint replacement surgery
    • Warner C. The use of the orthopedic perioperative autotransfusion (OrthoPAT) system in total joint replacement surgery. Orthop. Nurse 2001; 20: 29-32.
    • (2001) Orthop. Nurse , vol.20 , pp. 29-32
    • Warner, C.1
  • 18
    • 0034959732 scopus 로고    scopus 로고
    • Increased interleukin-6 in collected drainage blood after total knee athroplasty: An association with febrile reactions during retransfusion
    • Handel M, Winkler J, Hornlein RF, Northoff H, Heeg P, Teschner M, Sell S. Increased interleukin-6 in collected drainage blood after total knee athroplasty: an association with febrile reactions during retransfusion. Acta Orthop. Scand. 2001; 72: 270-272.
    • (2001) Acta Orthop. Scand. , vol.72 , pp. 270-272
    • Handel, M.1    Winkler, J.2    Hornlein, R.F.3    Northoff, H.4    Heeg, P.5    Teschner, M.6    Sell, S.7
  • 19
    • 33646191362 scopus 로고    scopus 로고
    • Maschinelle autotransfusionsverfahren. Anwendung und einfluß auf zytokine und leukocyten im autologen gewaschenen erythrocytenkonzentrat
    • Bentzien F, Brand JM, Rohrs E, Munkel H, Schmucher P. Maschinelle Autotransfusionsverfahren. Anwendung und Einfluß auf Zytokine und Leukocyten im autologen gewaschenen Erythrocytenkonzentrat. Anaesthesist 2000; 4510.
    • (2000) Anaesthesist , pp. 4510
    • Bentzien, F.1    Brand, J.M.2    Rohrs, E.3    Munkel, H.4    Schmucher, P.5
  • 20
    • 0031794010 scopus 로고    scopus 로고
    • Filterability of autotransfusion blood cells and plasma after total knee arthroplasty
    • Dalen T, Engstrom KG. Filterability of autotransfusion blood cells and plasma after total knee arthroplasty. Clin. Hemorheol. Microcirc. 1998; 19: 181-95
    • (1998) Clin. Hemorheol. Microcirc. , vol.19 , pp. 181-195
    • Dalen, T.1    Engstrom, K.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.