메뉴 건너뛰기




Volumn 22, Issue 9, 2005, Pages 707-712

Comparison of proximal isovelocity surface area method and pressure half time method for evaluation of mitral valve area in patients undergoing balloon mitral valvotomy

Author keywords

Mitral stenosis; Mitral valve area; Proximal isovelocity surface area; Valvuloplasty

Indexed keywords

ADULT; ARTICLE; BALLOON MITRAL VALVOTOMY; COMPARATIVE STUDY; DOPPLER ECHOCARDIOGRAPHY; ECHOCARDIOGRAPHY; EVALUATION; FEMALE; HUMAN; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MALE; MITRAL VALVE STENOSIS; PERCUTANEOUS CORONARY INTERVENTION; PRESSURE HALF TIME METHOD; PRIORITY JOURNAL; PROXIMAL ISOVELOCITY SURFACE AREA METHOD; RELIABILITY; STATISTICAL ANALYSIS; ALGORITHM; BALLOON DILATATION; BLOOD FLOW VELOCITY; ECHOGRAPHY; HEART VENTRICLE PRESSURE; MITRAL VALVE; PATHOLOGY; PHYSIOLOGY; REPRODUCIBILITY; TIME;

EID: 33644797790     PISSN: 07422822     EISSN: 15408175     Source Type: Journal    
DOI: 10.1111/j.1540-8175.2005.00082.x     Document Type: Article
Times cited : (10)

References (18)
  • 1
    • 0345491402 scopus 로고    scopus 로고
    • Long term clinical and echocardiographic follow up after percutaneous mitral valvotomy with the Inoue balloon
    • Hernandez R, Banuelos C, Alfonso F, et al: Long term clinical and echocardiographic follow up after percutaneous mitral valvotomy with the Inoue balloon. Circulation 1999;99:1580-1586.
    • (1999) Circulation , vol.99 , pp. 1580-1586
    • Hernandez, R.1    Banuelos, C.2    Alfonso, F.3
  • 2
    • 0023753489 scopus 로고    scopus 로고
    • Inaccuracy of mitral pressure half time immediately after percutaneous mitral valvotomy. Dependence on transmitral gradient and left atrial and ventricular compliance
    • Thomas JD, Wilkins GT, Choong CY, et al: Inaccuracy of mitral pressure half time immediately after percutaneous mitral valvotomy. Dependence on transmitral gradient and left atrial and ventricular compliance. Circulation 1998;78:980-983.
    • (1998) Circulation , vol.78 , pp. 980-983
    • Thomas, J.D.1    Wilkins, G.T.2    Choong, C.Y.3
  • 3
    • 0028724299 scopus 로고
    • What is the gold standard to measure mitral valve area in post mitral balloon valvotomy
    • (editorial)
    • Palacios IF: What is the gold standard to measure mitral valve area in post mitral balloon valvotomy (editorial). J Am Coll Cardiol 1994;33:315-316.
    • (1994) J Am Coll Cardiol , vol.33 , pp. 315-316
    • Palacios, I.F.1
  • 4
    • 0022613315 scopus 로고
    • Comparative accuracy of two-dimensional echocardiography and Doppler pressure-half time method in assessing severity of mitral stenosis in patients with and without prior commissurotomy
    • Smith MD, Handshoe R, Handshoe S, et al: Comparative accuracy of two-dimensional echocardiography and Doppler pressure-half time method in assessing severity of mitral stenosis in patients with and without prior commissurotomy. Circulation 1986;73:100-108.
    • (1986) Circulation , vol.73 , pp. 100-108
    • Smith, M.D.1    Handshoe, R.2    Handshoe, S.3
  • 5
    • 0027254652 scopus 로고
    • Validation of the proximal flow convergence method: Calculation of orifice area in patients with mitral stenosis
    • Rodriguez L, Thomas JD, Monterroso V, et al: Validation of the proximal flow convergence method: Calculation of orifice area in patients with mitral stenosis. Circulation 1993;88:1157-1165.
    • (1993) Circulation , vol.88 , pp. 1157-1165
    • Rodriguez, L.1    Thomas, J.D.2    Monterroso, V.3
  • 6
    • 0017353491 scopus 로고
    • Two-dimensional echocardiographic assessment of mitral stenosis
    • Nichol PM, Gilbert BW, Kisslo JA: Two-dimensional echocardiographic assessment of mitral stenosis. Circulation 1976;55:120-128.
    • (1976) Circulation , vol.55 , pp. 120-128
    • Nichol, P.M.1    Gilbert, B.W.2    Kisslo, J.A.3
  • 7
    • 0018355102 scopus 로고
    • Reliability and reproducibility of two-dimensional echocardiographic measurement of the stenotic mitral valve orifice area
    • Martin RP, Rakoswki H, Kleiman JH, et al: Reliability and reproducibility of two-dimensional echocardiographic measurement of the stenotic mitral valve orifice area. Am J Cardiol 1979;43:560-568.
    • (1979) Am J Cardiol , vol.43 , pp. 560-568
    • Martin, R.P.1    Rakoswki, H.2    Kleiman, J.H.3
  • 8
    • 0018623063 scopus 로고
    • Noninvasive assessment of atrioventricular pressure half time by Doppler ultrasound
    • Hatle L, Angelsen B, Thomsdal A: Noninvasive assessment of atrioventricular pressure half time by Doppler ultrasound. Circulation 1979;60:1096-1104.
    • (1979) Circulation , vol.60 , pp. 1096-1104
    • Hatle, L.1    Angelsen, B.2    Thomsdal, A.3
  • 9
    • 0030028355 scopus 로고    scopus 로고
    • Current status of flow convergence for clinical applications. Is it a leaning tower of "Pisa"?
    • Simpson I, Shioto T, Gharib M, et al: Current status of flow convergence for clinical applications. Is it a leaning tower of "Pisa"? J Am Coll Cardiol 1996;27:504-509.
    • (1996) J Am Coll Cardiol , vol.27 , pp. 504-509
    • Simpson, I.1    Shioto, T.2    Gharib, M.3
  • 10
    • 0029097505 scopus 로고
    • Comparison of proximal isovelocity surface area method with pressure half time and planimetry in evaluation of mitral stenosis
    • Rifkin RD, Harpes K, Tighe D: Comparison of proximal isovelocity surface area method with pressure half time and planimetry in evaluation of mitral stenosis. J Am Coll Cardiol 1995;26:458-465.
    • (1995) J Am Coll Cardiol , vol.26 , pp. 458-465
    • Rifkin, R.D.1    Harpes, K.2    Tighe, D.3
  • 11
    • 84908219488 scopus 로고
    • Statistical method for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG: Statistical method for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 12
    • 0030226242 scopus 로고    scopus 로고
    • Variability between methods of calculating mitral valve area: Simultaneous Doppler echocardiographic and cardiac catheterization studies conducted before and after percutaneous mitral valvuloplasty
    • Klarich KW, Rihal CS, Nishimura RA: Variability between methods of calculating mitral valve area: Simultaneous Doppler echocardiographic and cardiac catheterization studies conducted before and after percutaneous mitral valvuloplasty. J Am Soc Echocardiogr 1996;9:684-690.
    • (1996) J Am Soc Echocardiogr , vol.9 , pp. 684-690
    • Klarich, K.W.1    Rihal, C.S.2    Nishimura, R.A.3
  • 13
    • 0024595313 scopus 로고
    • Reliability of the Doppler pressure half time method for assessing effects of percutaneous mitral balloon valvuloplasty
    • Chen C, Wang Y, Guo B, et al: Reliability of the Doppler pressure half time method for assessing effects of percutaneous mitral balloon valvuloplasty. J Am Coll Cardiol 1989;13:1309-1313.
    • (1989) J Am Coll Cardiol , vol.13 , pp. 1309-1313
    • Chen, C.1    Wang, Y.2    Guo, B.3
  • 14
    • 0031057281 scopus 로고    scopus 로고
    • Assessment of accuracy of the Doppler pressure half time method in the estimation of the mitral valve area immediately after balloon mitral valvuloplasty
    • Pitsavos CE, Stefandis CI, Stratos CG, et al: Assessment of accuracy of the Doppler pressure half time method in the estimation of the mitral valve area immediately after balloon mitral valvuloplasty. Eur Heart J 1997;18:455-463.
    • (1997) Eur Heart J , vol.18 , pp. 455-463
    • Pitsavos, C.E.1    Stefandis, C.I.2    Stratos, C.G.3
  • 15
    • 0031440352 scopus 로고    scopus 로고
    • Calculation of mitral valve area in mitral stenosis using the proximal isovelocity surface area method. Comparison with two-dimensional planimetry and Doppler pressure halftime method
    • Oku K, Utsanomiya T, Mori H, et al: Calculation of mitral valve area in mitral stenosis using the proximal isovelocity surface area method. Comparison with two-dimensional planimetry and Doppler pressure halftime method. Jpn Heart J 1997;38:811-819.
    • (1997) Jpn Heart J , vol.38 , pp. 811-819
    • Oku, K.1    Utsanomiya, T.2    Mori, H.3
  • 16
    • 0026937150 scopus 로고
    • Validity of the proximal isovelocity surface area color Doppler method for calculating the valve area in patients with mitral stenosis. Comparison with 2D echocardiographic method
    • Centamore G, Campione S, Leto G, et al: Validity of the proximal isovelocity surface area color Doppler method for calculating the valve area in patients with mitral stenosis. Comparison with 2D echocardiographic method. G Ital Cardiol 1992;22:1201-1210.
    • (1992) G Ital Cardiol , vol.22 , pp. 1201-1210
    • Centamore, G.1    Campione, S.2    Leto, G.3
  • 17
    • 0028435830 scopus 로고
    • The accuracy and applicability of different methods in the Doppler technique for the quantification of mitral stenosis
    • Gonsales T, Torrecilla E, Garcia F, et al: The accuracy and applicability of different methods in the Doppler technique for the quantification of mitral stenosis. Rev Esp Cardiol 1994;37:316-326.
    • (1994) Rev Esp Cardiol , vol.37 , pp. 316-326
    • Gonsales, T.1    Torrecilla, E.2    Garcia, F.3
  • 18
    • 0031063525 scopus 로고
    • The "Proximal isovelocity surface area" method in assessing mitral valve area in patients with mitral stenosis and associated regurgitation
    • Centamore G, Galassi AR, Evola R, et al: The "Proximal isovelocity surface area" method in assessing mitral valve area in patients with mitral stenosis and associated regurgitation. G Ital Cardiol 1977;27:133-140.
    • (1977) G Ital Cardiol , vol.27 , pp. 133-140
    • Centamore, G.1    Galassi, A.R.2    Evola, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.