메뉴 건너뛰기




Volumn 441, Issue , 2005, Pages 237-242

Current status of trochanteric reattachment in complex total hip arthroplasty

Author keywords

[No Author keywords available]

Indexed keywords

CHROMIUM; COBALT;

EID: 33644788898     PISSN: 0009921X     EISSN: 15281132     Source Type: Journal    
DOI: 10.1097/01.blo.0000191274.42410.40     Document Type: Conference Paper
Times cited : (42)

References (16)
  • 1
    • 0035100855 scopus 로고    scopus 로고
    • Proximal femoral allograft for reconstruction of bone stock in revision arthroplasty of the hip. A 9 to 15 year follow-up
    • Blackley HR, Davis AM, Hutchison CR, Gross AE: Proximal femoral allograft for reconstruction of bone stock in revision arthroplasty of the hip. A 9 to 15 year follow-up. J Bone Joint Surg 83A:346-351, 2001.
    • (2001) J Bone Joint Surg , vol.83 A , pp. 346-351
    • Blackley, H.R.1    Davis, A.M.2    Hutchison, C.R.3    Gross, A.E.4
  • 2
    • 0014848821 scopus 로고
    • Total hip replacement by low-friction arthroplasty
    • Charnley J: Total hip replacement by low-friction arthroplasty. Clin Orthop Relat Res 72:7-21, 1970.
    • (1970) Clin Orthop Relat Res , vol.72 , pp. 7-21
    • Charnley, J.1
  • 4
    • 0020700562 scopus 로고
    • Re-attachment of the greater trochanter. The use of the trochanter cable-grip system
    • Dall DM, Miles AW: Re-attachment of the greater trochanter. The use of the trochanter cable-grip system. J Bone Joint Surg 65B:55-59, 1983.
    • (1983) J Bone Joint Surg , vol.65 B , pp. 55-59
    • Dall, D.M.1    Miles, A.W.2
  • 7
    • 0014525462 scopus 로고
    • Traumatic arthritis of the hip after dislocation and acetabular fractures: Treatment by mold arthroplasty: An end-result study using a new method of result evaluation
    • Harris WH: Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty: An end-result study using a new method of result evaluation. J Bone Joint Surg 51A:737-755, 1969.
    • (1969) J Bone Joint Surg , vol.51 A , pp. 737-755
    • Harris, W.H.1
  • 9
    • 0031278734 scopus 로고    scopus 로고
    • The Frank Stinchfield Award. Contribution of Cable Debris Generation to Accelerated Polyethylene Wear
    • Hop JD, Callaghan JJ, Olejniczak JP, et al: The Frank Stinchfield Award. Contribution of Cable Debris Generation to Accelerated Polyethylene Wear. Clin Orthop Relat Res 344:20-32, 1997.
    • (1997) Clin Orthop Relat Res , vol.344 , pp. 20-32
    • Hop, J.D.1    Callaghan, J.J.2    Olejniczak, J.P.3
  • 10
    • 0022514044 scopus 로고
    • A system for trochanteric osteotomy and reattachment for total hip arthroplasty with a ninety-nine percent union rate
    • Jensen NF, Harris WH: A system for trochanteric osteotomy and reattachment for total hip arthroplasty with a ninety-nine percent union rate. Clin Orthop Relat Res 208:174-181, 1986.
    • (1986) Clin Orthop Relat Res , vol.208 , pp. 174-181
    • Jensen, N.F.1    Harris, W.H.2
  • 11
    • 0026490462 scopus 로고
    • Debris from cobalt-chrome cable may cause acetabular loosening
    • Kelly SS, Johnston RC: Debris from cobalt-chrome cable may cause acetabular loosening. Clin Orthop Relat Res 285:140-146, 1992.
    • (1992) Clin Orthop Relat Res , vol.285 , pp. 140-146
    • Kelly, S.S.1    Johnston, R.C.2
  • 12
    • 0035114168 scopus 로고    scopus 로고
    • Reattachment of the greater trochanter using the Dall-Miles cable grip system in revision hip arthroplasty
    • Koyama K, Higuchi F, Kubo M, Okawa T, Inoue A: Reattachment of the greater trochanter using the Dall-Miles cable grip system in revision hip arthroplasty. J Orthop Sci 6:22-27, 2001.
    • (2001) J Orthop Sci , vol.6 , pp. 22-27
    • Koyama, K.1    Higuchi, F.2    Kubo, M.3    Okawa, T.4    Inoue, A.5
  • 13
    • 0032880756 scopus 로고    scopus 로고
    • The outcome of trochanteric reattachment in revision total hip arthroplasty with a cable grip system: Mean 6-year followup
    • McCarthy JC, Bono JV, Turner RH, Kremchek T, Lee J: The outcome of trochanteric reattachment in revision total hip arthroplasty with a cable grip system: Mean 6-year followup. J Arthroplasty 14:810-814, 1999.
    • (1999) J Arthroplasty , vol.14 , pp. 810-814
    • McCarthy, J.C.1    Bono, J.V.2    Turner, R.H.3    Kremchek, T.4    Lee, J.5
  • 16
    • 0029011936 scopus 로고
    • Extended proximal femoral osteotomy. A new technique for femoral revision arthroplasty
    • Younger TI, Bradford MS, Magnus RE, Paprosky WG: Extended proximal femoral osteotomy. A new technique for femoral revision arthroplasty. J Arthroplasty 10:329-338, 1995.
    • (1995) J Arthroplasty , vol.10 , pp. 329-338
    • Younger, T.I.1    Bradford, M.S.2    Magnus, R.E.3    Paprosky, W.G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.