메뉴 건너뛰기




Volumn 67, Issue 3, 2006, Pages 485-489

Inadvertent stenting of patent ductus arteriosus with amplatzer vascular plug

Author keywords

Amplatzer Vascular Plug; Patent ductus arteriosus; PDA

Indexed keywords

NITINOL;

EID: 33644757643     PISSN: 15221946     EISSN: 1522726X     Source Type: Journal    
DOI: 10.1002/ccd.20618     Document Type: Article
Times cited : (26)

References (11)
  • 1
    • 0014079566 scopus 로고
    • Fer verschluss des ductus arteriosus persistens ohne thorakotomie: 1, mitteilung
    • Porstmann W, Weirny L, Warnke H. Fer verschluss des ductus arteriosus persistens ohne thorakotomie: 1, Mitteilung. Thorazchirurgie 1967;15:199-203.
    • (1967) Thorazchirurgie , vol.15 , pp. 199-203
    • Porstmann, W.1    Weirny, L.2    Warnke, H.3
  • 2
    • 0028807412 scopus 로고
    • Transcatheter occlusion of patent ductus arteriosus
    • Moore JW, Patrick AC. Transcatheter occlusion of patent ductus arteriosus. J Interven Cardiol 1995;8:517-531.
    • (1995) J Interven Cardiol , vol.8 , pp. 517-531
    • Moore, J.W.1    Patrick, A.C.2
  • 3
    • 0010348217 scopus 로고    scopus 로고
    • Summary and comparison of patent ductus arteriosus closure devices
    • Rao PS. Summary and comparison of patent ductus arteriosus closure devices. Curr Intervent Cardiol Rep 2001;3:268-274.
    • (2001) Curr Intervent Cardiol Rep , vol.3 , pp. 268-274
    • Rao, P.S.1
  • 5
    • 33644748709 scopus 로고    scopus 로고
    • The Amplatzer Vascular Plug - An addition to our interventional armamentarium
    • Holzer R, Cao Q, Sandhu S, Hijazi ZM. The Amplatzer Vascular Plug - An addition to our interventional armamentarium. Ped Cardiol Today 2004;2(6):6-8.
    • (2004) Ped Cardiol Today , vol.2 , Issue.6 , pp. 6-8
    • Holzer, R.1    Cao, Q.2    Sandhu, S.3    Hijazi, Z.M.4
  • 6
    • 23044436365 scopus 로고    scopus 로고
    • Novel use of the Amplatzer Plug for closure of a patent ductus arteriosus
    • Hoyer MH. Novel use of the Amplatzer Plug for closure of a patent ductus arteriosus. Catheter Cardiovasc Interv 2005;65:577-580.
    • (2005) Catheter Cardiovasc Interv , vol.65 , pp. 577-580
    • Hoyer, M.H.1
  • 7
    • 23044442408 scopus 로고    scopus 로고
    • Not so fast with that novel use: Does AVP = PDA?
    • Cheatham JP. Not so fast with that novel use: does AVP = PDA? Catheter Cardiovasc Interv 2005;65:581-583.
    • (2005) Catheter Cardiovasc Interv , vol.65 , pp. 581-583
    • Cheatham, J.P.1
  • 9
    • 0030995970 scopus 로고    scopus 로고
    • Transvenous closure of secundum atrial septal defects - Preliminary results with a new self-expanding nitinol prosthesis in a swine model
    • Sharafuddin MJA, Gu X, Titus JL, Urness M, Cervera-Ceballos JJ, Amplatz K. Transvenous closure of secundum atrial septal defects - Preliminary results with a new self-expanding nitinol prosthesis in a swine model. Circulation 1997;95:2162-2168.
    • (1997) Circulation , vol.95 , pp. 2162-2168
    • Sharafuddin, M.J.A.1    Gu, X.2    Titus, J.L.3    Urness, M.4    Cervera-Ceballos, J.J.5    Amplatz, K.6
  • 11
    • 4544388023 scopus 로고    scopus 로고
    • New device for percutaneous closure of aortopulmonary collaterals
    • Hijazi ZM. New device for percutaneous closure of aortopulmonary collaterals. Catheter Cardiovasc Interv 2004;63:482-485.
    • (2004) Catheter Cardiovasc Interv , vol.63 , pp. 482-485
    • Hijazi, Z.M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.